Severe chest pain after retention of wireless pH capsule

Descripción del Articulo

The wireless capsule to measure gastroesophageal reflux, also known as pH monitoring capsule, is a technique used in ambulatory reflux monitoring. This capsule is introduced through a guide into the esophagus and is placed using a suction system and anchored to the esophageal mucosa. From there, it...

Descripción completa

Detalles Bibliográficos
Autores: Duarte-Chang, Calixto, Zúñiga Cisneros, Julio
Formato: artículo
Fecha de Publicación:2023
Institución:Sociedad de Gastroenterología del Perú
Repositorio:Revista de Gastroenterología del Perú
Lenguaje:español
OAI Identifier:oai:ojs.revistagastroperu.com:article/1555
Enlace del recurso:https://revistagastroperu.com/index.php/rgp/article/view/1555
Nivel de acceso:acceso abierto
Materia:Ácido gástrico
Esófago
Enfermedad por reflujo gastroesofágico
Gastric acid
Esophagus
Gastro esophageal reflux disease
id REVSGP_aa406260ea9a473607bb9269ce790157
oai_identifier_str oai:ojs.revistagastroperu.com:article/1555
network_acronym_str REVSGP
network_name_str Revista de Gastroenterología del Perú
repository_id_str .
spelling Severe chest pain after retention of wireless pH capsuleDolor torácico severo tras retención de cápsula inalámbrica de pHDuarte-Chang, CalixtoZúñiga Cisneros, JulioÁcido gástricoEsófagoEnfermedad por reflujo gastroesofágicoGastric acidEsophagusGastro esophageal reflux diseaseThe wireless capsule to measure gastroesophageal reflux, also known as pH monitoring capsule, is a technique used in ambulatory reflux monitoring. This capsule is introduced through a guide into the esophagus and is placed using a suction system and anchored to the esophageal mucosa. From there, it communicates with an external device using radio signals to record the activity of gastric acid in the esophagus over a specified period of time. Unlike the conventional technique, which involves inserting a tube through the nose into the esophagus, the wireless capsule may be a more comfortable and tolerable alternative for patients, potentially improving adherence to the procedure. In some cases, patients may present chest pain after placement of the pH monitoring capsule, however there is little evidence about the etiology and management. We present the case of a woman with a clinical picture of gastroesophageal reflux, with pH monitoring capsule placement, which resulted in severe chest pain that required endoscopic capsule removal.La cápsula inalámbrica para medir el reflujo gastroesofágico o tambien conocida como cápsula de pHmetría, es una técnica utilizada en la monitorización ambulatoria del reflujo. Esta cápsula es introducida mediante una guía al esofágo y se coloca mediante un sistema de succión y anclaje a la mucosa esofágica. De alli, se comunica con un dispositivo externo mediante señales de radio para registrar la actividad del ácido gástrico en el esófago durante un período determinado de tiempo. A diferencia de la técnica convencional, que implica la inserción de un tubo a través de la nariz hasta el esófago, la cápsula inalámbrica puede ser una alternativa más cómoda y tolerable para los pacientes, lo que podría mejorar la adherencia al procedimiento. Sin embargo, algunos pacientes pueden presentar dolor torácico tras la colocación de la cápsula de pHmetría. Presentamos el caso de una mujer con cuadro clínico de reflujo gastroesofágico, con colocación capsula de pHmetría inalámbrica, lo cual generó dolor torácico severo que precisó la retirada de la cápsula vía endoscópica.Sociedad de Gastroenterología del Perú2023-12-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistagastroperu.com/index.php/rgp/article/view/1555Revista de Gastroenterología del Perú; Vol. 43 No. 4 (2023); 383-386Revista de Gastroenterología del Perú; Vol. 43 Núm. 4 (2023); 383-3861609-722X1022-5129reponame:Revista de Gastroenterología del Perúinstname:Sociedad de Gastroenterología del Perúinstacron:SOCIOGASTROspahttps://revistagastroperu.com/index.php/rgp/article/view/1555/1222Derechos de autor 2023 Calixto Duarte-Chang, Julio Zúñiga Cisneroshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:ojs.revistagastroperu.com:article/15552023-12-24T13:08:26Z
dc.title.none.fl_str_mv Severe chest pain after retention of wireless pH capsule
Dolor torácico severo tras retención de cápsula inalámbrica de pH
title Severe chest pain after retention of wireless pH capsule
spellingShingle Severe chest pain after retention of wireless pH capsule
Duarte-Chang, Calixto
Ácido gástrico
Esófago
Enfermedad por reflujo gastroesofágico
Gastric acid
Esophagus
Gastro esophageal reflux disease
title_short Severe chest pain after retention of wireless pH capsule
title_full Severe chest pain after retention of wireless pH capsule
title_fullStr Severe chest pain after retention of wireless pH capsule
title_full_unstemmed Severe chest pain after retention of wireless pH capsule
title_sort Severe chest pain after retention of wireless pH capsule
dc.creator.none.fl_str_mv Duarte-Chang, Calixto
Zúñiga Cisneros, Julio
author Duarte-Chang, Calixto
author_facet Duarte-Chang, Calixto
Zúñiga Cisneros, Julio
author_role author
author2 Zúñiga Cisneros, Julio
author2_role author
dc.subject.none.fl_str_mv Ácido gástrico
Esófago
Enfermedad por reflujo gastroesofágico
Gastric acid
Esophagus
Gastro esophageal reflux disease
topic Ácido gástrico
Esófago
Enfermedad por reflujo gastroesofágico
Gastric acid
Esophagus
Gastro esophageal reflux disease
description The wireless capsule to measure gastroesophageal reflux, also known as pH monitoring capsule, is a technique used in ambulatory reflux monitoring. This capsule is introduced through a guide into the esophagus and is placed using a suction system and anchored to the esophageal mucosa. From there, it communicates with an external device using radio signals to record the activity of gastric acid in the esophagus over a specified period of time. Unlike the conventional technique, which involves inserting a tube through the nose into the esophagus, the wireless capsule may be a more comfortable and tolerable alternative for patients, potentially improving adherence to the procedure. In some cases, patients may present chest pain after placement of the pH monitoring capsule, however there is little evidence about the etiology and management. We present the case of a woman with a clinical picture of gastroesophageal reflux, with pH monitoring capsule placement, which resulted in severe chest pain that required endoscopic capsule removal.
publishDate 2023
dc.date.none.fl_str_mv 2023-12-21
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistagastroperu.com/index.php/rgp/article/view/1555
url https://revistagastroperu.com/index.php/rgp/article/view/1555
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistagastroperu.com/index.php/rgp/article/view/1555/1222
dc.rights.none.fl_str_mv Derechos de autor 2023 Calixto Duarte-Chang, Julio Zúñiga Cisneros
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2023 Calixto Duarte-Chang, Julio Zúñiga Cisneros
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad de Gastroenterología del Perú
publisher.none.fl_str_mv Sociedad de Gastroenterología del Perú
dc.source.none.fl_str_mv Revista de Gastroenterología del Perú; Vol. 43 No. 4 (2023); 383-386
Revista de Gastroenterología del Perú; Vol. 43 Núm. 4 (2023); 383-386
1609-722X
1022-5129
reponame:Revista de Gastroenterología del Perú
instname:Sociedad de Gastroenterología del Perú
instacron:SOCIOGASTRO
instname_str Sociedad de Gastroenterología del Perú
instacron_str SOCIOGASTRO
institution SOCIOGASTRO
reponame_str Revista de Gastroenterología del Perú
collection Revista de Gastroenterología del Perú
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1870164774135791616
score 12.824051
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).