Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:

Descripción del Articulo

Advanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantag...

Descripción completa

Detalles Bibliográficos
Autores: Ramirez Ramos, Cristhian Felipe, Aranzazu-Uribe, Mateo, Pamplona, Alejandra, Gallego, Catalina, Uribe-Molano, Juan David, Muñoz Sierra, Juan, Vanegas-Cardona, Diego, Tenorio-Mejía, Carlos, Eusse-Gomez, Carlos Alberto, Uribe-Londoño, Carlos Esteban
Formato: artículo
Fecha de Publicación:2021
Institución:Instituto Nacional Cardiovascular
Repositorio:Archivos peruanos de cardiología y cirugía cardiovascular
Lenguaje:español
OAI Identifier:oai:ojs.apcyccv.org.pe:article/134
Enlace del recurso:https://apcyccv.org.pe/index.php/apccc/article/view/134
Nivel de acceso:acceso abierto
Materia:Contrapulsador intraaórtico
Insuficiencia cardiaca
Trasplante de corazón
Intra-Aortic balloon pumping
Heart failure
Heart transplantation
id REVINCOR_19f2023d7da08258af82d5623763f114
oai_identifier_str oai:ojs.apcyccv.org.pe:article/134
network_acronym_str REVINCOR
network_name_str Archivos peruanos de cardiología y cirugía cardiovascular
repository_id_str
spelling Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report: Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardiaco. Reporte de casos: Ramirez Ramos, Cristhian FelipeAranzazu-Uribe, MateoPamplona, AlejandraGallego, CatalinaUribe-Molano, Juan DavidMuñoz Sierra, JuanVanegas-Cardona, DiegoTenorio-Mejía, CarlosEusse-Gomez, Carlos AlbertoUribe-Londoño, Carlos EstebanContrapulsador intraaórticoInsuficiencia cardiacaTrasplante de corazónIntra-Aortic balloon pumpingHeart failureHeart transplantationAdvanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantage of limiting the patient’s movements, hence exposing him or her to the hazards of immobility and threatening the success of the procedure or hindering recovery. Access through the subclavian artery has become an attractive alternative since it doesn’t impair the patient’s mobility, and there is increasing evidence supporting its use. We present the first case of subclavian counterpulsation balloon implantation in a cardiovascular care center in Colombia.La falla cardíaca avanzada es un importante problema de salud, siendo la única alternativa definitiva de manejo el trasplante cardíaco o los dispositivos de asistencia ventricular. El balón de contrapulsación intraaórtico por acceso femoral como puente a trasplante, que es aún de uso frecuente, tiene la desventaja de limitar la actividad del paciente, exponiéndolo a las complicaciones de la inmovilidad, lo que puede amenazar el éxito del procedimiento o, al menos, complicar la recuperación después del trasplante. El acceso por la arteria subclavia para el implante se ha convertido en una alternativa atractiva pues evita todas estas limitaciones del acceso femoral y hay evidencia que favorece su utilización como primera alternativa en este contexto. Presentamos los primeros casos de implante de balón de contrapulsación por vía subclavia en un centro de atención cardiovascular de alta complejidad en Colombia.Instituto Nacional Cardiovascular “Carlos Alberto Peschiera Carrillo” – INCOR, EsSalud2021-05-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-Review articleArtículo evaluado por paresapplication/pdftext/htmlhttps://apcyccv.org.pe/index.php/apccc/article/view/134Archivos Peruanos de Cardiología y Cirugía Cardiovascular; Vol. 2 No. 2 (2021); 135-140Archivos Peruanos de Cardiología y Cirugía Cardiovascular; Vol. 2 Núm. 2 (2021); 135-1402708-7212reponame:Archivos peruanos de cardiología y cirugía cardiovascularinstname:Instituto Nacional Cardiovascularinstacron:INCORspahttps://apcyccv.org.pe/index.php/apccc/article/view/134/154https://apcyccv.org.pe/index.php/apccc/article/view/134/247Derechos de autor 2021 La revista es titular de la primera publicación, luego el autor dando crédito a la primera publicación.info:eu-repo/semantics/openAccessoai:ojs.apcyccv.org.pe:article/1342023-02-13T02:54:24Z
dc.title.none.fl_str_mv Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
Balón de contrapulsación intraaórtico por acceso subclavio como puente a trasplante cardiaco. Reporte de casos:
title Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
spellingShingle Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
Ramirez Ramos, Cristhian Felipe
Contrapulsador intraaórtico
Insuficiencia cardiaca
Trasplante de corazón
Intra-Aortic balloon pumping
Heart failure
Heart transplantation
title_short Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
title_full Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
title_fullStr Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
title_full_unstemmed Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
title_sort Intra-aortic balloon contrapulsation through subclavian access as a bridge to heart transplantation. Case report:
dc.creator.none.fl_str_mv Ramirez Ramos, Cristhian Felipe
Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan
Vanegas-Cardona, Diego
Tenorio-Mejía, Carlos
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
author Ramirez Ramos, Cristhian Felipe
author_facet Ramirez Ramos, Cristhian Felipe
Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan
Vanegas-Cardona, Diego
Tenorio-Mejía, Carlos
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
author_role author
author2 Aranzazu-Uribe, Mateo
Pamplona, Alejandra
Gallego, Catalina
Uribe-Molano, Juan David
Muñoz Sierra, Juan
Vanegas-Cardona, Diego
Tenorio-Mejía, Carlos
Eusse-Gomez, Carlos Alberto
Uribe-Londoño, Carlos Esteban
author2_role author
author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Contrapulsador intraaórtico
Insuficiencia cardiaca
Trasplante de corazón
Intra-Aortic balloon pumping
Heart failure
Heart transplantation
topic Contrapulsador intraaórtico
Insuficiencia cardiaca
Trasplante de corazón
Intra-Aortic balloon pumping
Heart failure
Heart transplantation
description Advanced heart failure is a major health problem for which heart transplantation or left ventricular assist devices are the only effective treatments. Intra-aortic balloon pump inserted using femoral artery access as a bridge to heart transplantation is still frequently used, but has the disadvantage of limiting the patient’s movements, hence exposing him or her to the hazards of immobility and threatening the success of the procedure or hindering recovery. Access through the subclavian artery has become an attractive alternative since it doesn’t impair the patient’s mobility, and there is increasing evidence supporting its use. We present the first case of subclavian counterpulsation balloon implantation in a cardiovascular care center in Colombia.
publishDate 2021
dc.date.none.fl_str_mv 2021-05-21
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-Review article
Artículo evaluado por pares
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://apcyccv.org.pe/index.php/apccc/article/view/134
url https://apcyccv.org.pe/index.php/apccc/article/view/134
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://apcyccv.org.pe/index.php/apccc/article/view/134/154
https://apcyccv.org.pe/index.php/apccc/article/view/134/247
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
text/html
dc.publisher.none.fl_str_mv Instituto Nacional Cardiovascular “Carlos Alberto Peschiera Carrillo” – INCOR, EsSalud
publisher.none.fl_str_mv Instituto Nacional Cardiovascular “Carlos Alberto Peschiera Carrillo” – INCOR, EsSalud
dc.source.none.fl_str_mv Archivos Peruanos de Cardiología y Cirugía Cardiovascular; Vol. 2 No. 2 (2021); 135-140
Archivos Peruanos de Cardiología y Cirugía Cardiovascular; Vol. 2 Núm. 2 (2021); 135-140
2708-7212
reponame:Archivos peruanos de cardiología y cirugía cardiovascular
instname:Instituto Nacional Cardiovascular
instacron:INCOR
instname_str Instituto Nacional Cardiovascular
instacron_str INCOR
institution INCOR
reponame_str Archivos peruanos de cardiología y cirugía cardiovascular
collection Archivos peruanos de cardiología y cirugía cardiovascular
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1793529932090966016
score 13.95948
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).