Mandibular reconstruction with polyetheretherketone computer designed implant

Descripción del Articulo

A 22 years old male was referred to emergency for a gunshot trauma that involves the inferior third of the face with extension to the both submandibular and submental regions. The patient presented at the inferior half of the mandible, bodies and symphysis, a comminuted mandible fracture and two dis...

Descripción completa

Detalles Bibliográficos
Autores: Oré-Acevedo, Juan Francisco, Castillo-Chávez, Katerin, Huaranga-Bustamante, Walter
Formato: artículo
Fecha de Publicación:2014
Institución:Colegio Médico del Perú
Repositorio:Acta Médica Peruana
Lenguaje:español
OAI Identifier:oai:ojs.pkp.sfu.ca:article/1364
Enlace del recurso:https://amp.cmp.org.pe/index.php/AMP/article/view/1364
Nivel de acceso:acceso abierto
Materia:Mandible
reconstruction
implant
prosthesis
polyetheretherketone
id REVCMP_39fcca2426679ce87493a2318f2e5479
oai_identifier_str oai:ojs.pkp.sfu.ca:article/1364
network_acronym_str REVCMP
network_name_str Acta Médica Peruana
repository_id_str .
spelling Mandibular reconstruction with polyetheretherketone computer designed implantReconstrucción mandibular con implante hecho a medida de polieteretercetonaOré-Acevedo, Juan Francisco Castillo-Chávez, Katerin Huaranga-Bustamante, Walter MandiblereconstructionimplantprosthesispolyetheretherketoneA 22 years old male was referred to emergency for a gunshot trauma that involves the inferior third of the face with extension to the both submandibular and submental regions. The patient presented at the inferior half of the mandible, bodies and symphysis, a comminuted mandible fracture and two displaced fractures at the upper half of the mandible; though no teeth were missing. He underwent at emergency an open reduction and osteosynthesis with wires. A polyetheretherketone (PEEK) computer designed implant was placed to replace the lost bone tissue and restore the facial aesthetics. The PEEK implant is actually a new, simple and versatile method for complex mandibular reconstructions.Se describe el caso de un varón de 21 años, que ingresa a emergencia por sufrir un traumatismo, por arma de fuego de alta velocidad. El área comprometida es el tercio inferior facial, con extensión a las regiones submentoniana y submandibulares. El paciente presentó una fractura conminuta en la mitad inferior mandibular y dos fracturas con desplazamiento en la mitad superior mandibular, sin pérdida ni compromiso de piezas dentarias. Posterior a la reducción cruenta y osteosíntesis con alambre quirúrgico realizada en emergencia, en la reconstrucción se utilizó un implante hecho a medida basado en imágenes tomográficas. El implante de polieteretercetona (PEEK) fue seleccionado para reemplazar la pérdida ósea y para restaurar la anatomía facial. Los implantes de PEEK son actualmente una nueva opción biocompatible, simple y versátil para reconstrucciones mandibulares complejas Se presentan las imágenes tomográficas antes y después del implante, imágenes del paciente antes y después del implante y el proceso quirúrgico de implante.Colegio Médico del Perú2014-03-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttps://amp.cmp.org.pe/index.php/AMP/article/view/136410.35663/amp.2014.311.1364ACTA MEDICA PERUANA; Vol 31 No 1 (2014): January - March; 37-41ACTA MEDICA PERUANA; Vol. 31 Núm. 1 (2014): Enero-Marzo; 37-411728-59171018-8800reponame:Acta Médica Peruanainstname:Colegio Médico del Perúinstacron:CMPspahttps://amp.cmp.org.pe/index.php/AMP/article/view/1364/814https://amp.cmp.org.pe/index.php/AMP/article/view/1364/1336Copyright (c) 2020 ACTA MEDICA PERUANAinfo:eu-repo/semantics/openAccessoai:ojs.pkp.sfu.ca:article/13642023-07-06T05:56:25Z
dc.title.none.fl_str_mv Mandibular reconstruction with polyetheretherketone computer designed implant
Reconstrucción mandibular con implante hecho a medida de polieteretercetona
title Mandibular reconstruction with polyetheretherketone computer designed implant
spellingShingle Mandibular reconstruction with polyetheretherketone computer designed implant
Oré-Acevedo, Juan Francisco
Mandible
reconstruction
implant
prosthesis
polyetheretherketone
title_short Mandibular reconstruction with polyetheretherketone computer designed implant
title_full Mandibular reconstruction with polyetheretherketone computer designed implant
title_fullStr Mandibular reconstruction with polyetheretherketone computer designed implant
title_full_unstemmed Mandibular reconstruction with polyetheretherketone computer designed implant
title_sort Mandibular reconstruction with polyetheretherketone computer designed implant
dc.creator.none.fl_str_mv Oré-Acevedo, Juan Francisco
Castillo-Chávez, Katerin
Huaranga-Bustamante, Walter
author Oré-Acevedo, Juan Francisco
author_facet Oré-Acevedo, Juan Francisco
Castillo-Chávez, Katerin
Huaranga-Bustamante, Walter
author_role author
author2 Castillo-Chávez, Katerin
Huaranga-Bustamante, Walter
author2_role author
author
dc.subject.none.fl_str_mv Mandible
reconstruction
implant
prosthesis
polyetheretherketone
topic Mandible
reconstruction
implant
prosthesis
polyetheretherketone
description A 22 years old male was referred to emergency for a gunshot trauma that involves the inferior third of the face with extension to the both submandibular and submental regions. The patient presented at the inferior half of the mandible, bodies and symphysis, a comminuted mandible fracture and two displaced fractures at the upper half of the mandible; though no teeth were missing. He underwent at emergency an open reduction and osteosynthesis with wires. A polyetheretherketone (PEEK) computer designed implant was placed to replace the lost bone tissue and restore the facial aesthetics. The PEEK implant is actually a new, simple and versatile method for complex mandibular reconstructions.
publishDate 2014
dc.date.none.fl_str_mv 2014-03-29
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://amp.cmp.org.pe/index.php/AMP/article/view/1364
10.35663/amp.2014.311.1364
url https://amp.cmp.org.pe/index.php/AMP/article/view/1364
identifier_str_mv 10.35663/amp.2014.311.1364
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://amp.cmp.org.pe/index.php/AMP/article/view/1364/814
https://amp.cmp.org.pe/index.php/AMP/article/view/1364/1336
dc.rights.none.fl_str_mv Copyright (c) 2020 ACTA MEDICA PERUANA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2020 ACTA MEDICA PERUANA
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
text/html
dc.publisher.none.fl_str_mv Colegio Médico del Perú
publisher.none.fl_str_mv Colegio Médico del Perú
dc.source.none.fl_str_mv ACTA MEDICA PERUANA; Vol 31 No 1 (2014): January - March; 37-41
ACTA MEDICA PERUANA; Vol. 31 Núm. 1 (2014): Enero-Marzo; 37-41
1728-5917
1018-8800
reponame:Acta Médica Peruana
instname:Colegio Médico del Perú
instacron:CMP
instname_str Colegio Médico del Perú
instacron_str CMP
institution CMP
reponame_str Acta Médica Peruana
collection Acta Médica Peruana
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1816075107001434112
score 13.888049
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).