Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation
Descripción del Articulo
The application of the iterative method of phase retrieval to series of images obtained at different defocus values is described and discussed. It is shown that the iterative scheme is robust in the presence of discontinuities in the phase. The application of these methods to a set of experimental i...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2008 |
| Institución: | Instituto Peruano de Energía Nuclear |
| Repositorio: | IPEN-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.ipen.gob.pe:20.500.13054/534 |
| Enlace del recurso: | https://hdl.handle.net/20.500.13054/534 |
| Nivel de acceso: | acceso abierto |
| Materia: | Métodos de iteración Imágenes Rayos X Microscopía electrónica por transmisión |
| id |
IPEN_02f70322aa1d0ff02a044ac198f09188 |
|---|---|
| oai_identifier_str |
oai:repositorio.ipen.gob.pe:20.500.13054/534 |
| network_acronym_str |
IPEN |
| network_name_str |
IPEN-Institucional |
| repository_id_str |
3248 |
| spelling |
Lobato, IvánMontoya, EduardoLobato, IvánMontoya, Eduardo2016-01-13T16:12:34Z2016-01-13T16:12:34Z2008-11Lobato I, Montoya E. Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation. Informe Científico Tecnológico. Volumen 7 (2007) p. 47-51.1684-1662https://hdl.handle.net/20.500.13054/534The application of the iterative method of phase retrieval to series of images obtained at different defocus values is described and discussed. It is shown that the iterative scheme is robust in the presence of discontinuities in the phase. The application of these methods to a set of experimental images taken using X-ray imaging is investigated. A computer program which can reproduce the simulations and analyse experimental image data is briefly discussed.Se describe la aplicación del método iterativo de recuperación de fase a una serie de imágenes obtenidas a diferentes valores de desenfoque. Se muestra que el esquema iterativo es robusto en presencia de discontinuidades en la fase. La aplicación de este método a un conjunto de imágenes experimentales tomadas usando rayos-X es investigada. Se discute brevemente el programa de computadora que puede reproducir la simulación y el análisis experimental de los datos de las imágenes.Instituto Peruano de Energía Nuclearapplication/pdfengLima (Perú)PEinfo:eu-repo/semantics/openAccessInstituto Peruano de Energía NuclearRepositorio Institucional del Instituto Peruano de Energía Nuclearreponame:IPEN-Institucionalinstname:Instituto Peruano de Energía Nuclearinstacron:IPENMétodos de iteraciónImágenesRayos XMicroscopía electrónica por transmisiónApplication of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variationinfo:eu-repo/semantics/articleORIGINALPag 47-51 ICT-2007.pdfPag 47-51 ICT-2007.pdfapplication/pdf436676https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/1/Pag%2047-51%20ICT-2007.pdf5f513af9a94bc09424ef2b3614db645cMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-8103https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/2/license.txt7ecf7b0639239de61a3a1ede9c397fecMD52TEXTPag 47-51 ICT-2007.pdf.txtPag 47-51 ICT-2007.pdf.txtExtracted texttext/plain16149https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/3/Pag%2047-51%20ICT-2007.pdf.txtc629d1855d640f527a101ea4f560bffcMD53THUMBNAILPag 47-51 ICT-2007.pdf.jpgPag 47-51 ICT-2007.pdf.jpgGenerated Thumbnailimage/jpeg22612https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/4/Pag%2047-51%20ICT-2007.pdf.jpgb58575f730976da0b6c7fe2d061a40a0MD5420.500.13054/534oai:repositorio.ipen.gob.pe:20.500.13054/5342022-02-07 18:07:05.976Repositorio Institucional del Instituto Peruano de Energía Nuclearrepositorio@ipen.gob.peU2UgRGlzdHJpYnV5ZSBiYWpvIHVuYSBMaWNlbmNpYSBDcmVhdGl2ZSBDb21tb25zIEF0cmlidWNpw7NuLU5vQ29tZXJjaWFsLVNpbkRlcml2YXIgNC4wIEludGVybmFjaW9uYWwuCg== |
| dc.title.es_PE.fl_str_mv |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| title |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| spellingShingle |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation Lobato, Iván Métodos de iteración Imágenes Rayos X Microscopía electrónica por transmisión |
| title_short |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| title_full |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| title_fullStr |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| title_full_unstemmed |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| title_sort |
Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation |
| dc.creator.none.fl_str_mv |
Lobato, Iván Montoya, Eduardo |
| author |
Lobato, Iván |
| author_facet |
Lobato, Iván Montoya, Eduardo |
| author_role |
author |
| author2 |
Montoya, Eduardo |
| author2_role |
author |
| dc.contributor.author.fl_str_mv |
Lobato, Iván Montoya, Eduardo |
| dc.subject.es_PE.fl_str_mv |
Métodos de iteración Imágenes Rayos X Microscopía electrónica por transmisión |
| topic |
Métodos de iteración Imágenes Rayos X Microscopía electrónica por transmisión |
| description |
The application of the iterative method of phase retrieval to series of images obtained at different defocus values is described and discussed. It is shown that the iterative scheme is robust in the presence of discontinuities in the phase. The application of these methods to a set of experimental images taken using X-ray imaging is investigated. A computer program which can reproduce the simulations and analyse experimental image data is briefly discussed. |
| publishDate |
2008 |
| dc.date.accessioned.none.fl_str_mv |
2016-01-13T16:12:34Z |
| dc.date.available.none.fl_str_mv |
2016-01-13T16:12:34Z |
| dc.date.issued.fl_str_mv |
2008-11 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.citation.es_PE.fl_str_mv |
Lobato I, Montoya E. Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation. Informe Científico Tecnológico. Volumen 7 (2007) p. 47-51. |
| dc.identifier.issn.none.fl_str_mv |
1684-1662 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.13054/534 |
| identifier_str_mv |
Lobato I, Montoya E. Application of the Allen–Oxley iterative method of phase retrieval to series of images obtained by focus variation. Informe Científico Tecnológico. Volumen 7 (2007) p. 47-51. 1684-1662 |
| url |
https://hdl.handle.net/20.500.13054/534 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.es_PE.fl_str_mv |
application/pdf |
| dc.publisher.es_PE.fl_str_mv |
Lima (Perú) |
| dc.publisher.country.es_PE.fl_str_mv |
PE |
| dc.source.es_PE.fl_str_mv |
Instituto Peruano de Energía Nuclear Repositorio Institucional del Instituto Peruano de Energía Nuclear |
| dc.source.none.fl_str_mv |
reponame:IPEN-Institucional instname:Instituto Peruano de Energía Nuclear instacron:IPEN |
| instname_str |
Instituto Peruano de Energía Nuclear |
| instacron_str |
IPEN |
| institution |
IPEN |
| reponame_str |
IPEN-Institucional |
| collection |
IPEN-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/1/Pag%2047-51%20ICT-2007.pdf https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/2/license.txt https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/3/Pag%2047-51%20ICT-2007.pdf.txt https://repositorio.ipen.gob.pe/bitstream/20.500.13054/534/4/Pag%2047-51%20ICT-2007.pdf.jpg |
| bitstream.checksum.fl_str_mv |
5f513af9a94bc09424ef2b3614db645c 7ecf7b0639239de61a3a1ede9c397fec c629d1855d640f527a101ea4f560bffc b58575f730976da0b6c7fe2d061a40a0 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Institucional del Instituto Peruano de Energía Nuclear |
| repository.mail.fl_str_mv |
repositorio@ipen.gob.pe |
| _version_ |
1846785881632931840 |
| score |
12.80667 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).