Preliminary analysis for evaluation of local site effects in Lima city, Peru from ground motion data by using the spectral inversion method

Descripción del Articulo

Effects of local site, propagation path and source in ground motion records observed in Lima, Peru, were separated by the spectral inversion method proposed by Iwata and Irikura (1986 [1], 1988 [2]) to examine the relation between local subsurface conditions and local site amplifications in a freque...

Descripción completa

Detalles Bibliográficos
Autores: Quispe, Selene, Yamanaka, Hiroaki, Aguilar, Zenon, Lazares, Fernando, Tavera, Hernando
Formato: artículo
Fecha de Publicación:2013
Institución:Instituto Geofísico del Perú
Repositorio:IGP-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.igp.gob.pe:20.500.12816/2075
Enlace del recurso:http://hdl.handle.net/20.500.12816/2075
https://doi.org/10.20965/jdr.2013.p0243
Nivel de acceso:acceso abierto
Materia:Lima City
La Molina
Callao
Site amplification factor
Spectral inversion method
Seismology
http://purl.org/pe-repo/ocde/ford#1.05.00
http://purl.org/pe-repo/ocde/ford#1.05.04
Descripción
Sumario:Effects of local site, propagation path and source in ground motion records observed in Lima, Peru, were separated by the spectral inversion method proposed by Iwata and Irikura (1986 [1], 1988 [2]) to examine the relation between local subsurface conditions and local site amplifications in a frequency range from 0.5 to 20 Hz. S-wave portions of accelerograms in horizontal components observed at 5 stations for 11 events along the Pacific coast of Lima city, Peru, were analyzed. The Q factor was obtained from our inversion results as frequency dependent function QS( f) = 80.4 f 0.63. In terms of local site effects, stations located on alluvial gravel deposits were likely to suffer amplification at frequencies larger than 4 Hz, while one station (CAL site) located on soft soil sediment has different behavior of amplification. We also compared our results with 1-D theoretical computation, observed standard spectral ratio and observed H/V spectra in previous studies, finding that site responses determined by different methods are similar. In addition, we analyzed the relationship between average S-wave velocity in the top 10 meters and the average site amplification factor in a frequency range between 0.5 Hz and 10.0 Hz, showing a good correlation between the two parameters. We also calculated the average transfer function (AvTF) to compare it with the existing amplification map for Lima city, and found that our calculations differed from this map.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).