Design and implementation of a low cost particulate material transducer
Descripción del Articulo
The authors gratefully acknowledge support for this Project from The Universidad Nacional de San Agustín, The Universidad Catolica San Pablo and The CONCYTEC (Peruvian Research Council).
| Autores: | , , |
|---|---|
| Formato: | objeto de conferencia |
| Fecha de Publicación: | 2018 |
| Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
| Repositorio: | CONCYTEC-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/548 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12390/548 https://doi.org/10.1109/I2MTC.2018.8409523 |
| Nivel de acceso: | acceso abierto |
| Materia: | Risk assessment Costs Health risks Mining Design and implementations Environmental health Environmental perturbations Low-cost devices Mining activities Particle materials Particulate materials https://purl.org/pe-repo/ocde/ford#1.05.02 |
| id |
CONC_febf6c7baded848339ca4b2c2393303a |
|---|---|
| oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/548 |
| network_acronym_str |
CONC |
| network_name_str |
CONCYTEC-Institucional |
| repository_id_str |
4689 |
| dc.title.none.fl_str_mv |
Design and implementation of a low cost particulate material transducer |
| title |
Design and implementation of a low cost particulate material transducer |
| spellingShingle |
Design and implementation of a low cost particulate material transducer Tejada E.P. Risk assessment Costs Health risks Mining Design and implementations Environmental health Environmental perturbations Low-cost devices Mining activities Particle materials Particulate materials https://purl.org/pe-repo/ocde/ford#1.05.02 |
| title_short |
Design and implementation of a low cost particulate material transducer |
| title_full |
Design and implementation of a low cost particulate material transducer |
| title_fullStr |
Design and implementation of a low cost particulate material transducer |
| title_full_unstemmed |
Design and implementation of a low cost particulate material transducer |
| title_sort |
Design and implementation of a low cost particulate material transducer |
| author |
Tejada E.P. |
| author_facet |
Tejada E.P. Falcon V.C. Cayo E.H. |
| author_role |
author |
| author2 |
Falcon V.C. Cayo E.H. |
| author2_role |
author author |
| dc.contributor.author.fl_str_mv |
Tejada E.P. Falcon V.C. Cayo E.H. |
| dc.subject.none.fl_str_mv |
Risk assessment |
| topic |
Risk assessment Costs Health risks Mining Design and implementations Environmental health Environmental perturbations Low-cost devices Mining activities Particle materials Particulate materials https://purl.org/pe-repo/ocde/ford#1.05.02 |
| dc.subject.es_PE.fl_str_mv |
Costs Health risks Mining Design and implementations Environmental health Environmental perturbations Low-cost devices Mining activities Particle materials Particulate materials |
| dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#1.05.02 |
| description |
The authors gratefully acknowledge support for this Project from The Universidad Nacional de San Agustín, The Universidad Catolica San Pablo and The CONCYTEC (Peruvian Research Council). |
| publishDate |
2018 |
| dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
| dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
| dc.date.issued.fl_str_mv |
2018 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
| format |
conferenceObject |
| dc.identifier.isbn.none.fl_str_mv |
urn:isbn:9781538622223 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/548 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1109/I2MTC.2018.8409523 |
| dc.identifier.scopus.none.fl_str_mv |
2-s2.0-85050765690 |
| identifier_str_mv |
urn:isbn:9781538622223 2-s2.0-85050765690 |
| url |
https://hdl.handle.net/20.500.12390/548 https://doi.org/10.1109/I2MTC.2018.8409523 |
| dc.language.iso.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers Inc. |
| publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers Inc. |
| dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
| instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
| instacron_str |
CONCYTEC |
| institution |
CONCYTEC |
| reponame_str |
CONCYTEC-Institucional |
| collection |
CONCYTEC-Institucional |
| repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
| repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
| _version_ |
1844883027828670464 |
| spelling |
Publicationrp00958600rp00956600rp00957600Tejada E.P.Falcon V.C.Cayo E.H.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2018urn:isbn:9781538622223https://hdl.handle.net/20.500.12390/548https://doi.org/10.1109/I2MTC.2018.84095232-s2.0-85050765690The authors gratefully acknowledge support for this Project from The Universidad Nacional de San Agustín, The Universidad Catolica San Pablo and The CONCYTEC (Peruvian Research Council).This work presents the design, implementation, calibration and test of a transducer system for Particle Material - PM based on the sensor GP2Y1010. This sensor is the principal element of many commercial PM transducers, but its sensitivity for environmental perturbations (such as humidity, temperature, etc.) implies the using of complex instrumentation circuits which increases the final price of this product. In this work is proposed a low cost PM transducer, the main characteristics of its instrumentation circuit are detailed. The characteristics of the proposed transducer such as resolution, precision, range of measurement, temperature operation are near among of the characteristics of commercial transducers. The purpose of this transducer is the monitoring of particle material due to mining activity around the Arequipa city, since the particle material concentration out of permissible range is a potential risk for the public health, in this sense the measurement with a reliable and low cost device is a challenging task.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengInstitute of Electrical and Electronics Engineers Inc.I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedingsinfo:eu-repo/semantics/openAccessRisk assessmentCosts-1Health risks-1Mining-1Design and implementations-1Environmental health-1Environmental perturbations-1Low-cost devices-1Mining activities-1Particle materials-1Particulate materials-1https://purl.org/pe-repo/ocde/ford#1.05.02-1Design and implementation of a low cost particulate material transducerinfo:eu-repo/semantics/conferenceObjectreponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/548oai:repositorio.concytec.gob.pe:20.500.12390/5482024-05-30 15:57:55.464http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c52bd660-be95-4bc5-94b2-af9662e13a96"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Design and implementation of a low cost particulate material transducer</Title> <PublishedIn> <Publication> <Title>I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings</Title> </Publication> </PublishedIn> <PublicationDate>2018</PublicationDate> <DOI>https://doi.org/10.1109/I2MTC.2018.8409523</DOI> <SCP-Number>2-s2.0-85050765690</SCP-Number> <ISBN>urn:isbn:9781538622223</ISBN> <Authors> <Author> <DisplayName>Tejada E.P.</DisplayName> <Person id="rp00958" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Falcon V.C.</DisplayName> <Person id="rp00956" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Cayo E.H.</DisplayName> <Person id="rp00957" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Institute of Electrical and Electronics Engineers Inc.</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>Risk assessment</Keyword> <Keyword>Costs</Keyword> <Keyword>Health risks</Keyword> <Keyword>Mining</Keyword> <Keyword>Design and implementations</Keyword> <Keyword>Environmental health</Keyword> <Keyword>Environmental perturbations</Keyword> <Keyword>Low-cost devices</Keyword> <Keyword>Mining activities</Keyword> <Keyword>Particle materials</Keyword> <Keyword>Particulate materials</Keyword> <Abstract>This work presents the design, implementation, calibration and test of a transducer system for Particle Material - PM based on the sensor GP2Y1010. This sensor is the principal element of many commercial PM transducers, but its sensitivity for environmental perturbations (such as humidity, temperature, etc.) implies the using of complex instrumentation circuits which increases the final price of this product. In this work is proposed a low cost PM transducer, the main characteristics of its instrumentation circuit are detailed. The characteristics of the proposed transducer such as resolution, precision, range of measurement, temperature operation are near among of the characteristics of commercial transducers. The purpose of this transducer is the monitoring of particle material due to mining activity around the Arequipa city, since the particle material concentration out of permissible range is a potential risk for the public health, in this sense the measurement with a reliable and low cost device is a challenging task.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
| score |
13.413352 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).