Regularized spectral log difference technique for ultrasonic attenuation imaging

Descripción del Articulo

The attenuation coefficient slope (ACS) has the potential to be used for tissue characterization and as a diagnostic ultrasound tool, hence complementing B-mode images. The ACS can be valuable for estimation of other ultrasound parameters such as the backscatter coefficient. There is a well-known tr...

Descripción completa

Detalles Bibliográficos
Autor: Coila Pacompia, Andres Leonel
Formato: tesis de maestría
Fecha de Publicación:2017
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/1810
Enlace del recurso:https://hdl.handle.net/20.500.12390/1810
Nivel de acceso:acceso abierto
Materia:Ultrasonido
Reconstrucción de imágenes digitales
Imágenes en alta resolución
https://purl.org/pe-repo/ocde/ford#2.02.05
id CONC_ace5b76f001cd9deb87ba9c0868dfa99
oai_identifier_str oai:repositorio.concytec.gob.pe:20.500.12390/1810
network_acronym_str CONC
network_name_str CONCYTEC-Institucional
repository_id_str 4689
spelling Publicationrp04768600Coila Pacompia, Andres Leonel2024-05-30T23:13:38Z2024-05-30T23:13:38Z2017https://hdl.handle.net/20.500.12390/1810The attenuation coefficient slope (ACS) has the potential to be used for tissue characterization and as a diagnostic ultrasound tool, hence complementing B-mode images. The ACS can be valuable for estimation of other ultrasound parameters such as the backscatter coefficient. There is a well-known tradeoff between the precision of the estimated ACS values and the data block size used in spectral-based techniques such as the spectral log difference (SLD). This trade-off limits the practical usefulness of spectral-based attenuation imaging techniques. In this thesis work, the regularized spectral log difference (RSLD) technique is presented in detail and evaluated with simulations and experiments with physical phantoms, ex vivo and in vivo. The ACS values obtained when using the RSLD technique were compared to the ones obtained when using the SLD technique, as well as the ground truth ACS values obtained with insertion loss techniques.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengPontificia Universidad Católica del Perúinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/4.0/UltrasonidoReconstrucción de imágenes digitales-1Imágenes en alta resolución-1https://purl.org/pe-repo/ocde/ford#2.02.05-1Regularized spectral log difference technique for ultrasonic attenuation imaginginfo:eu-repo/semantics/masterThesisreponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/1810oai:repositorio.concytec.gob.pe:20.500.12390/18102024-05-30 16:05:08.82https://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e72e4b63-7d9c-4245-a1a6-152007d95979"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Regularized spectral log difference technique for ultrasonic attenuation imaging</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2017</PublicationDate> <Authors> <Author> <DisplayName>Coila Pacompia, Andres Leonel</DisplayName> <Person id="rp04768" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Pontificia Universidad Católica del Perú</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nc-nd/4.0/</License> <Keyword>Ultrasonido</Keyword> <Keyword>Reconstrucción de imágenes digitales</Keyword> <Keyword>Imágenes en alta resolución</Keyword> <Abstract>The attenuation coefficient slope (ACS) has the potential to be used for tissue characterization and as a diagnostic ultrasound tool, hence complementing B-mode images. The ACS can be valuable for estimation of other ultrasound parameters such as the backscatter coefficient. There is a well-known tradeoff between the precision of the estimated ACS values and the data block size used in spectral-based techniques such as the spectral log difference (SLD). This trade-off limits the practical usefulness of spectral-based attenuation imaging techniques. In this thesis work, the regularized spectral log difference (RSLD) technique is presented in detail and evaluated with simulations and experiments with physical phantoms, ex vivo and in vivo. The ACS values obtained when using the RSLD technique were compared to the ones obtained when using the SLD technique, as well as the ground truth ACS values obtained with insertion loss techniques.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1
dc.title.none.fl_str_mv Regularized spectral log difference technique for ultrasonic attenuation imaging
title Regularized spectral log difference technique for ultrasonic attenuation imaging
spellingShingle Regularized spectral log difference technique for ultrasonic attenuation imaging
Coila Pacompia, Andres Leonel
Ultrasonido
Reconstrucción de imágenes digitales
Imágenes en alta resolución
https://purl.org/pe-repo/ocde/ford#2.02.05
title_short Regularized spectral log difference technique for ultrasonic attenuation imaging
title_full Regularized spectral log difference technique for ultrasonic attenuation imaging
title_fullStr Regularized spectral log difference technique for ultrasonic attenuation imaging
title_full_unstemmed Regularized spectral log difference technique for ultrasonic attenuation imaging
title_sort Regularized spectral log difference technique for ultrasonic attenuation imaging
author Coila Pacompia, Andres Leonel
author_facet Coila Pacompia, Andres Leonel
author_role author
dc.contributor.author.fl_str_mv Coila Pacompia, Andres Leonel
dc.subject.none.fl_str_mv Ultrasonido
topic Ultrasonido
Reconstrucción de imágenes digitales
Imágenes en alta resolución
https://purl.org/pe-repo/ocde/ford#2.02.05
dc.subject.es_PE.fl_str_mv Reconstrucción de imágenes digitales
Imágenes en alta resolución
dc.subject.ocde.none.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.05
description The attenuation coefficient slope (ACS) has the potential to be used for tissue characterization and as a diagnostic ultrasound tool, hence complementing B-mode images. The ACS can be valuable for estimation of other ultrasound parameters such as the backscatter coefficient. There is a well-known tradeoff between the precision of the estimated ACS values and the data block size used in spectral-based techniques such as the spectral log difference (SLD). This trade-off limits the practical usefulness of spectral-based attenuation imaging techniques. In this thesis work, the regularized spectral log difference (RSLD) technique is presented in detail and evaluated with simulations and experiments with physical phantoms, ex vivo and in vivo. The ACS values obtained when using the RSLD technique were compared to the ones obtained when using the SLD technique, as well as the ground truth ACS values obtained with insertion loss techniques.
publishDate 2017
dc.date.accessioned.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.available.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.issued.fl_str_mv 2017
dc.type.none.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12390/1810
url https://hdl.handle.net/20.500.12390/1810
dc.language.iso.none.fl_str_mv eng
language eng
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.publisher.none.fl_str_mv Pontificia Universidad Católica del Perú
publisher.none.fl_str_mv Pontificia Universidad Católica del Perú
dc.source.none.fl_str_mv reponame:CONCYTEC-Institucional
instname:Consejo Nacional de Ciencia Tecnología e Innovación
instacron:CONCYTEC
instname_str Consejo Nacional de Ciencia Tecnología e Innovación
instacron_str CONCYTEC
institution CONCYTEC
reponame_str CONCYTEC-Institucional
collection CONCYTEC-Institucional
repository.name.fl_str_mv Repositorio Institucional CONCYTEC
repository.mail.fl_str_mv repositorio@concytec.gob.pe
_version_ 1839175795843530752
score 13.448654
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).