In Vivo Estimation of Attenuation and Backscatter Coefficients From Human Thyroids

Descripción del Articulo

Fine-needle aspiration (FNA) remains the gold standard for the diagnosis of thyroid cancer. However, currently, a large number of FNA biopsies result in negative or undetermined diagnosis, which suggests that better noninvasive tools are needed for the clinical management of thyroid cancer. Spectral...

Descripción completa

Detalles Bibliográficos
Autores: Rouyer, J, Cueva, T, Yamamoto, T, Portal, A, Lavarello, RJ
Formato: artículo
Fecha de Publicación:2016
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/1087
Enlace del recurso:https://hdl.handle.net/20.500.12390/1087
https://doi.org/10.1109/TUFFC.2016.2532932
Nivel de acceso:acceso abierto
Materia:Form factor
Attenuation coefficient
Backscatter coefficient
https://purl.org/pe-repo/ocde/ford#2.06.02
Descripción
Sumario:Fine-needle aspiration (FNA) remains the gold standard for the diagnosis of thyroid cancer. However, currently, a large number of FNA biopsies result in negative or undetermined diagnosis, which suggests that better noninvasive tools are needed for the clinical management of thyroid cancer. Spectral-based quantitative ultrasound (QUS) characterizations may offer a better diagnostic management as previously demonstrated in mouse cancer models ex vivo. As a first step toward understanding the potential of QUS markers for thyroid disease management, this paper deals with the spectral-based QUS estimation of healthy human thyroids in vivo. Twenty volunteers were inspected by a trained radiologist using two ultrasonic imaging systems, which allowed them to acquire radio-frequency data spanning the 3-16-MHz frequency range. Estimates of attenuation coefficient slope (ACS) using the spectral logarithmic difference method had an average value of 1.69 dB/(cm·MHz) with a standard deviation of 0.28 dB/cm·MHz. Estimates of backscatter coefficient (BSC) using the reference-phantom method had an average value of 0.18 sr -1 · cm -1 over the useful frequency range. The intersubject variability when estimating BSCs was less than 1.5 dB over the analysis frequency range. Further, the effectiveness of three scattering models (i.e., fluid sphere, Gaussian, and exponential form factors) when fitting the experimentally estimated BSCs was assessed. The exponential form factor was found to provide the best overall goodness of fit (R 2 = 0.917), followed by the Gaussian (R 2 = 0.807) and the fluid-sphere models (R 2 = 0.752). For all scattering models used in this study, average estimates of the effective scatterer diameter were between 44 and 56 μm. Overall, an excellent agreement in the estimated attenuation and BSCs with both scanners was exhibited.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).