Evaluation of an integrated wood-burning stove with water tank system for heating rural homes in the Andean highlands of Peru

Descripción del Articulo

In this work, we study an improved wood-burning stove with a water tank placed in the flue gas outlet for use as a heater. This system takes advantage of the waste heat of the gases that pass through the chimney to heat the water contained in the tank. The evaluations were carried out in a house loc...

Descripción completa

Detalles Bibliográficos
Autores: Soria L.S.G., Cabana-Hancco W.R., Montoya L.A., Palo-Tejada E.
Formato: artículo
Fecha de Publicación:2020
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/2588
Enlace del recurso:https://hdl.handle.net/20.500.12390/2588
https://doi.org/10.1088/1742-6596/1433/1/012005
Nivel de acceso:acceso abierto
Materia:General Physics and Astronomy
http://purl.org/pe-repo/ocde/ford#1.05.11
Descripción
Sumario:In this work, we study an improved wood-burning stove with a water tank placed in the flue gas outlet for use as a heater. This system takes advantage of the waste heat of the gases that pass through the chimney to heat the water contained in the tank. The evaluations were carried out in a house located in the district of San Antonio de Chuca (Imata), province of Caylloma, department of Arequipa, Peru, located above 4500m above sea level, where temperatures decrease to -20 °C during winter. A method is proposed to measure the power input of the integrated tank, which consists of finding the maximum power that the flue gas delivers to the water in the tank when the stove is turned on. Once this power has been identified, the wood-burning stove is replaced by an electric heating system that delivers the same power to heat the water. Once the electrical system has been calibrated, the water in the tank is heated to different temperatures, and the following are calculated: the accumulated energy, the time needed to reach the desired temperature and the amount of wood that would be used if the kitchen were used for heating. The power that the heater can deliver to the test house is thus determined. If the water in the tank is heated to 70 °C, this heating system can deliver an average power value of 450 W from 20:00 to 5:00 the next day. © Published under licence by IOP Publishing Ltd.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).