Comprehensive Study of Natural Radioactivity in Building Materials: A Case Study in Ica, Peru

Descripción del Articulo

This study evaluates radon exhalation rates and assesses the potential radiological risks of external exposure to primordial radionuclides in building materials employed in the Ica region of Peru, particularly those with high uranium content. The radon exhalation rates are currently measured using a...

Descripción completa

Detalles Bibliográficos
Autores: Liz, Rafael, Pereyra, Patrizia, Muñoz, Daniel, Viera, Victor, López Herrera, Maria Elena, Rojas, Jhonny, Palacios, Daniel, Díaz, Félix, Cerna, Nhell, Rojas, Segundo, Sajo-Bohus, Laszlo
Formato: artículo
Fecha de Publicación:2023
Institución:Universidad Autónoma del Perú
Repositorio:AUTONOMA-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.autonoma.edu.pe:20.500.13067/3181
Enlace del recurso:https://hdl.handle.net/20.500.13067/3181
https://doi.org/10.3390/atmos15030279
Nivel de acceso:acceso abierto
Materia:Building materials
Natural radioactivity
Radon exhalation rate
Gamma index
https://purl.org/pe-repo/ocde/ford#2.01.00
Descripción
Sumario:This study evaluates radon exhalation rates and assesses the potential radiological risks of external exposure to primordial radionuclides in building materials employed in the Ica region of Peru, particularly those with high uranium content. The radon exhalation rates are currently measured using a combination of a closed chamber and an active monitor. We proposed a novel method that effectively ensured a hermetic seal for the closed chamber and guaranteed that the efficient maintenance of secular equilibrium. The obtained results ranged from below the detection limit (BDL) to a maximum of 52.3 mBq · kg−1h−1. Gamma spectrometry was employed to measure the concentrations of radionuclides by utilizing a 3′ × 3′ NaI detector. The analysis of cement samples revealed a strong positive correlation between the activity concentration of radium and the radon exhalation rate. The activity concentrations for radionuclides varied, with values ranging from BDL to 60.6 mBq · kg−1h−1 for 226Ra, BDL to 22.3 mBq · kg−1h−1 for 232Th, and BDL to 1074 mBq · kg−1h−1 for 40K. These findings contribute valuable insight to decision-making processes in the Peruvian construction industry, particularly regarding material safety and radiological risk management.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).