Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016

Descripción del Articulo

Objective: To determine preventive measures compliance on patients with mechanical ventilation in theCritical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospectiveobservational study of longitudinal cut, the population was comprised of the patients that entered th...

Descripción completa

Detalles Bibliográficos
Autores: Medina Laura, Gladys, Gutiérrez Crespo, Hugo, Zamudio Eslava, Luisa A.
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Peruana Unión
Repositorio:Revista UPEU - Revista Científica de Ciencias de la Salud
Lenguaje:español
OAI Identifier:oai:ojs2.revistas.upeu.edu.pe:article/238
Enlace del recurso:https://revistas.upeu.edu.pe/index.php/RCCS/article/view/238
Nivel de acceso:acceso abierto
Materia:Preventive measures, pneumonia, mechanical ventilation
Medidas preventivas, neumonía, ventilación mecánica.
id 2411-0094_13f44ae433724ba67dac60377d98a78f
oai_identifier_str oai:ojs2.revistas.upeu.edu.pe:article/238
network_acronym_str 2411-0094
repository_id_str .
network_name_str Revista UPEU - Revista Científica de Ciencias de la Salud
spelling Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016Cumplimiento de las medidas preventivas en pacientes con ventilación mecánica en la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen, 2016Medina Laura, Gladys Gutiérrez Crespo, Hugo Zamudio Eslava, Luisa A. Preventive measures, pneumonia, mechanical ventilationMedidas preventivas, neumonía, ventilación mecánica.Objective: To determine preventive measures compliance on patients with mechanical ventilation in theCritical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospectiveobservational study of longitudinal cut, the population was comprised of the patients that entered theCritical Care Unit. For convenience, a non-probabilistic sample was used, which was comprised of50 patients who were studied during the months of June to November of 2016. Patients who passedaway within 48 hours of admission were excluded. The instrument used was a verification list madeup of a set of six preventive measures containing dichotomous type answers, with a reliability of 0.80using the Richarson Kuder method. Results: 52% of the patients who average ≥ 60 years old, with amale predominance, the respiratory pathology constituted 60% of the cases, 58% of the patients hadbetween 10 and 19 days of use of mechanical ventilation and 78% of the did not show pneumonia.The adequate handling of the airway, hand hygiene during the handling of the airways and headbedside elevation, showed 73.6% of compliance, while the evaluation and records of the necessityof sedoanalgesia showed 70.9% of compliance. Conclusions: in 54% of the studied patients thepreventive measures were achieved.Objetivo: Determinar el cumplimiento de las medidas preventivas en pacientes con ventilación mecánicaen la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen. Material y Métodos:Estudio observacional, prospectivo y de corte longitudinal. La población estuvo conformada por lospacientes que ingresaron a la Unidad de Cuidados Críticos. Se utilizó una muestra no probabilísticapor conveniencia, conformada por 50 pacientes que fueron estudiados durante los meses de junio anoviembre del año 2016; fueron excluidos los pacientes que fallecieron en las primeras 48 horas desu ingreso. El instrumento utilizado fue una lista de verificación constituida por un conjunto de seismedidas preventivas con respuestas de tipo dicotómica, con una confiabilidad de 0.80, mediante elmétodo de Kuder Richarson. Resultados: El 52% de los pacientes tenía una edad ≥ 60 años, conpredominio del sexo masculino. La patología respiratoria se representó en el 60% de los casos, el58% de los pacientes tuvieron entre 10 y 19 días de uso de ventilación mecánica y el 78% no presentóneumonía. El manejo adecuado de la vía área, la higiene de manos durante el manejo de la víaaérea y la elevación de la cabecera, presentaron 73.6% de cumplimiento, mientras que la valoracióny registro de la necesidad de sedoanalgesia, presentó 70.9% de cumplimiento. Conclusiones: En el54% de los pacientes estudiados se cumplieron las medidas preventivas.Universidad Peruana Unión2019-08-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upeu.edu.pe/index.php/RCCS/article/view/23810.17162/rccs.v11i1.238Revista Científica de Ciencias de la Salud; Vol 11 No 1 (2018): Revista Científica de Ciencias de la SaludRevista Científica de Ciencias de la Salud; Vol. 11 Núm. 1 (2018): Revista Científica de Ciencias de la Salud2411-00942306-060310.17162/rccs.v11i1reponame:Revista UPEU - Revista Científica de Ciencias de la Saludinstname:Universidad Peruana Unióninstacron:UPEUspahttps://revistas.upeu.edu.pe/index.php/RCCS/article/view/238/247Derechos de autor 2019 Gladys Medina Laura##common.commaListSeparator##Hugo Gutiérrez Crespo##common.commaListSeparator##Luisa A. Zamudio Eslavahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess2020-02-16T15:50:21Zmail@mail.com -
dc.title.none.fl_str_mv Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
Cumplimiento de las medidas preventivas en pacientes con ventilación mecánica en la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen, 2016
title Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
spellingShingle Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
Medina Laura, Gladys
Preventive measures, pneumonia, mechanical ventilation
Medidas preventivas, neumonía, ventilación mecánica.
title_short Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_full Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_fullStr Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_full_unstemmed Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_sort Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
dc.creator.none.fl_str_mv Medina Laura, Gladys
Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author Medina Laura, Gladys
author_facet Medina Laura, Gladys
Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author_role author
author2 Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author2_role author
author
dc.subject.none.fl_str_mv Preventive measures, pneumonia, mechanical ventilation
Medidas preventivas, neumonía, ventilación mecánica.
topic Preventive measures, pneumonia, mechanical ventilation
Medidas preventivas, neumonía, ventilación mecánica.
dc.description.none.fl_txt_mv Objective: To determine preventive measures compliance on patients with mechanical ventilation in theCritical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospectiveobservational study of longitudinal cut, the population was comprised of the patients that entered theCritical Care Unit. For convenience, a non-probabilistic sample was used, which was comprised of50 patients who were studied during the months of June to November of 2016. Patients who passedaway within 48 hours of admission were excluded. The instrument used was a verification list madeup of a set of six preventive measures containing dichotomous type answers, with a reliability of 0.80using the Richarson Kuder method. Results: 52% of the patients who average ≥ 60 years old, with amale predominance, the respiratory pathology constituted 60% of the cases, 58% of the patients hadbetween 10 and 19 days of use of mechanical ventilation and 78% of the did not show pneumonia.The adequate handling of the airway, hand hygiene during the handling of the airways and headbedside elevation, showed 73.6% of compliance, while the evaluation and records of the necessityof sedoanalgesia showed 70.9% of compliance. Conclusions: in 54% of the studied patients thepreventive measures were achieved.
Objetivo: Determinar el cumplimiento de las medidas preventivas en pacientes con ventilación mecánicaen la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen. Material y Métodos:Estudio observacional, prospectivo y de corte longitudinal. La población estuvo conformada por lospacientes que ingresaron a la Unidad de Cuidados Críticos. Se utilizó una muestra no probabilísticapor conveniencia, conformada por 50 pacientes que fueron estudiados durante los meses de junio anoviembre del año 2016; fueron excluidos los pacientes que fallecieron en las primeras 48 horas desu ingreso. El instrumento utilizado fue una lista de verificación constituida por un conjunto de seismedidas preventivas con respuestas de tipo dicotómica, con una confiabilidad de 0.80, mediante elmétodo de Kuder Richarson. Resultados: El 52% de los pacientes tenía una edad ≥ 60 años, conpredominio del sexo masculino. La patología respiratoria se representó en el 60% de los casos, el58% de los pacientes tuvieron entre 10 y 19 días de uso de ventilación mecánica y el 78% no presentóneumonía. El manejo adecuado de la vía área, la higiene de manos durante el manejo de la víaaérea y la elevación de la cabecera, presentaron 73.6% de cumplimiento, mientras que la valoracióny registro de la necesidad de sedoanalgesia, presentó 70.9% de cumplimiento. Conclusiones: En el54% de los pacientes estudiados se cumplieron las medidas preventivas.
description Objective: To determine preventive measures compliance on patients with mechanical ventilation in theCritical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospectiveobservational study of longitudinal cut, the population was comprised of the patients that entered theCritical Care Unit. For convenience, a non-probabilistic sample was used, which was comprised of50 patients who were studied during the months of June to November of 2016. Patients who passedaway within 48 hours of admission were excluded. The instrument used was a verification list madeup of a set of six preventive measures containing dichotomous type answers, with a reliability of 0.80using the Richarson Kuder method. Results: 52% of the patients who average ≥ 60 years old, with amale predominance, the respiratory pathology constituted 60% of the cases, 58% of the patients hadbetween 10 and 19 days of use of mechanical ventilation and 78% of the did not show pneumonia.The adequate handling of the airway, hand hygiene during the handling of the airways and headbedside elevation, showed 73.6% of compliance, while the evaluation and records of the necessityof sedoanalgesia showed 70.9% of compliance. Conclusions: in 54% of the studied patients thepreventive measures were achieved.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-05
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.upeu.edu.pe/index.php/RCCS/article/view/238
10.17162/rccs.v11i1.238
url https://revistas.upeu.edu.pe/index.php/RCCS/article/view/238
identifier_str_mv 10.17162/rccs.v11i1.238
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.upeu.edu.pe/index.php/RCCS/article/view/238/247
dc.rights.none.fl_str_mv Derechos de autor 2019 Gladys Medina Laura##common.commaListSeparator##Hugo Gutiérrez Crespo##common.commaListSeparator##Luisa A. Zamudio Eslava
https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2019 Gladys Medina Laura##common.commaListSeparator##Hugo Gutiérrez Crespo##common.commaListSeparator##Luisa A. Zamudio Eslava
https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Peruana Unión
publisher.none.fl_str_mv Universidad Peruana Unión
dc.source.none.fl_str_mv Revista Científica de Ciencias de la Salud; Vol 11 No 1 (2018): Revista Científica de Ciencias de la Salud
Revista Científica de Ciencias de la Salud; Vol. 11 Núm. 1 (2018): Revista Científica de Ciencias de la Salud
2411-0094
2306-0603
10.17162/rccs.v11i1
reponame:Revista UPEU - Revista Científica de Ciencias de la Salud
instname:Universidad Peruana Unión
instacron:UPEU
reponame_str Revista UPEU - Revista Científica de Ciencias de la Salud
collection Revista UPEU - Revista Científica de Ciencias de la Salud
instname_str Universidad Peruana Unión
instacron_str UPEU
institution UPEU
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701202259531005952
score 13.92687
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).