Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop

Descripción del Articulo

OBJETIVE. To know efficacy acceptability and causes of discontinuation in IUD users. SETING. Family Planning Service at ALAIH. MALTERIAL AND METHODS. During 1992-1994, 3706 TCu-380A IUDs were inserted to healthy patients, 3167 intergenesic, with prior information and normal gynecological exam; contr...

Descripción completa

Detalles Bibliográficos
Autores: Escudero, Francisco, Delgadillo, Laura, Villena, Arturo
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/972
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/972
Nivel de acceso:acceso abierto
id 2304-5132_c4eb5eb2421be3be47dc60024da1d4e3
oai_identifier_str oai:ojs.spog:article/972
network_acronym_str 2304-5132
repository_id_str .
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
spelling Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza ArchbishopTres años de experiencia con el dispositivo intrauterino medicado con cobre (TCu-380A) en el Hospital Nacional Arzobispo LoayzaEscudero, FranciscoDelgadillo, LauraVillena, ArturoOBJETIVE. To know efficacy acceptability and causes of discontinuation in IUD users. SETING. Family Planning Service at ALAIH. MALTERIAL AND METHODS. During 1992-1994, 3706 TCu-380A IUDs were inserted to healthy patients, 3167 intergenesic, with prior information and normal gynecological exam; controls were monthly, semestral and annual to determine secondary effects and cause and date of discontinuation. Rates were estimated by year and total accumulation and reasons of discontinuation by life-table survival analysis. RESULTS. From 3167 women, 361 discontinued for different reasons, 1667 continued use and 1139 did not return to control. Discontinuation at three years was 24,8% per 100 woman-year use, because of pregnancy 1,10 (n=16), IUD expulsion 10,19 (n=148), pain 1,17 (n=17), abnormal vaginal bleeding 1,99 (n=29), pelvic infection 1,44 (n=21), personal reasons 8,73 (n=127), and medical reasons 0,19 (n=3); accumulated total conttinuity use rate was 75,1. CONCLUSIONS. Efficacy of TCu-380A IUD is similar to that reported by other investigators. Loss to follow-up is high, especially during the first year.OBJETIVO. Conocer la efectividad, aceptabilidad y causas de discontinuación de las usuarias del DIU que acuden a la consulta habitual, LUGAR. Servicio de Planificación Familiar del HNAL. MATERIAL Y METODOS. Durante el periodo de 1992-1994 se insertó 3706 DIU (TCu-380A) a mujeres sanas, 3 167 en el periodo intergenésico, quienes previa información y examen ginecológico normal aceptaron este método; se programó controles mensuales, semestrales y anuales, para evaluar efectos secundariosy registrar causa y fecha de discontinuación. Se calculó las tasas acumuladas por año, totales y por razones de discontinuación, utilizándo análisis de sobrevida, mediante el método de tabla de vida. RESULTADOS. De un total de 3167 mujeres, 361 discontinuaron por diferentes razones, 1667 continúan activas al finalizar el estudio y 1139 no retornaron a su control; se encontró una tasa acumulada de discontinuación al 3.er año de 24,8 por 100 mujeres año uso. Las tasas, brutas acumuladas por causas fueron: embarazo 1,10 (n=16), expulsión 10,19 (n=148), dolor 1,17 (n=17), sangrado vaginal anormal 1,99 (n=29), infección pélvica 1,44 (n=21), razones personales 8,73 (n=127), razones médicas 0,19 (n=3) y una tasa bruta acumulada de continuación de uso de 75,1. CONCLUSIONES. La efectividad del DIU (TCu-380A) es similar a la publicada por otros investigadores; la pérdida de seguimiento es elevada, sobre todo en el primer año.Sociedad Peruana de Obstetricia y Ginecología2015-06-19info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/97210.31403/rpgo.v44i972Revista Peruana de Ginecología y Obstetricia; Vol. 44, Núm. 2 (1998); 114-1172304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/972/934info:eu-repo/semantics/openAccess2021-05-31T15:50:31Zmail@mail.com -
dc.title.none.fl_str_mv Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
Tres años de experiencia con el dispositivo intrauterino medicado con cobre (TCu-380A) en el Hospital Nacional Arzobispo Loayza
title Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
spellingShingle Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
Escudero, Francisco
title_short Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
title_full Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
title_fullStr Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
title_full_unstemmed Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
title_sort Three years of experience with medicated intrauterine device with copper (TCu-380A) at the National Hospital Loayza Archbishop
dc.creator.none.fl_str_mv Escudero, Francisco
Delgadillo, Laura
Villena, Arturo
author Escudero, Francisco
author_facet Escudero, Francisco
Delgadillo, Laura
Villena, Arturo
author_role author
author2 Delgadillo, Laura
Villena, Arturo
author2_role author
author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv OBJETIVE. To know efficacy acceptability and causes of discontinuation in IUD users. SETING. Family Planning Service at ALAIH. MALTERIAL AND METHODS. During 1992-1994, 3706 TCu-380A IUDs were inserted to healthy patients, 3167 intergenesic, with prior information and normal gynecological exam; controls were monthly, semestral and annual to determine secondary effects and cause and date of discontinuation. Rates were estimated by year and total accumulation and reasons of discontinuation by life-table survival analysis. RESULTS. From 3167 women, 361 discontinued for different reasons, 1667 continued use and 1139 did not return to control. Discontinuation at three years was 24,8% per 100 woman-year use, because of pregnancy 1,10 (n=16), IUD expulsion 10,19 (n=148), pain 1,17 (n=17), abnormal vaginal bleeding 1,99 (n=29), pelvic infection 1,44 (n=21), personal reasons 8,73 (n=127), and medical reasons 0,19 (n=3); accumulated total conttinuity use rate was 75,1. CONCLUSIONS. Efficacy of TCu-380A IUD is similar to that reported by other investigators. Loss to follow-up is high, especially during the first year.
OBJETIVO. Conocer la efectividad, aceptabilidad y causas de discontinuación de las usuarias del DIU que acuden a la consulta habitual, LUGAR. Servicio de Planificación Familiar del HNAL. MATERIAL Y METODOS. Durante el periodo de 1992-1994 se insertó 3706 DIU (TCu-380A) a mujeres sanas, 3 167 en el periodo intergenésico, quienes previa información y examen ginecológico normal aceptaron este método; se programó controles mensuales, semestrales y anuales, para evaluar efectos secundariosy registrar causa y fecha de discontinuación. Se calculó las tasas acumuladas por año, totales y por razones de discontinuación, utilizándo análisis de sobrevida, mediante el método de tabla de vida. RESULTADOS. De un total de 3167 mujeres, 361 discontinuaron por diferentes razones, 1667 continúan activas al finalizar el estudio y 1139 no retornaron a su control; se encontró una tasa acumulada de discontinuación al 3.er año de 24,8 por 100 mujeres año uso. Las tasas, brutas acumuladas por causas fueron: embarazo 1,10 (n=16), expulsión 10,19 (n=148), dolor 1,17 (n=17), sangrado vaginal anormal 1,99 (n=29), infección pélvica 1,44 (n=21), razones personales 8,73 (n=127), razones médicas 0,19 (n=3) y una tasa bruta acumulada de continuación de uso de 75,1. CONCLUSIONES. La efectividad del DIU (TCu-380A) es similar a la publicada por otros investigadores; la pérdida de seguimiento es elevada, sobre todo en el primer año.
description OBJETIVE. To know efficacy acceptability and causes of discontinuation in IUD users. SETING. Family Planning Service at ALAIH. MALTERIAL AND METHODS. During 1992-1994, 3706 TCu-380A IUDs were inserted to healthy patients, 3167 intergenesic, with prior information and normal gynecological exam; controls were monthly, semestral and annual to determine secondary effects and cause and date of discontinuation. Rates were estimated by year and total accumulation and reasons of discontinuation by life-table survival analysis. RESULTS. From 3167 women, 361 discontinued for different reasons, 1667 continued use and 1139 did not return to control. Discontinuation at three years was 24,8% per 100 woman-year use, because of pregnancy 1,10 (n=16), IUD expulsion 10,19 (n=148), pain 1,17 (n=17), abnormal vaginal bleeding 1,99 (n=29), pelvic infection 1,44 (n=21), personal reasons 8,73 (n=127), and medical reasons 0,19 (n=3); accumulated total conttinuity use rate was 75,1. CONCLUSIONS. Efficacy of TCu-380A IUD is similar to that reported by other investigators. Loss to follow-up is high, especially during the first year.
publishDate 2015
dc.date.none.fl_str_mv 2015-06-19
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/972
10.31403/rpgo.v44i972
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/972
identifier_str_mv 10.31403/rpgo.v44i972
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/972/934
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 44, Núm. 2 (1998); 114-117
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701289828265492480
score 13.905282
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).