OBJETIVE: To compare the rate of expulsion of intrauterine device (IUD) Copper T 380A inserted do postalumbramiento and within 48 hours after delivery. LOCATION: Department of Obstetrics Archbishop Loayza Hospital. MATERIALS AND METHODS: The study included 614 postpartum women who are TCu 380A IUD i...

Descripción completa

Detalles Bibliográficos
Autores: Escudero, Francisco, Delgadillo, L., Pérez, K., Muñante, M.
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/561
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/561
Nivel de acceso:acceso abierto
id 2304-5132_8dfda07564d024b53aff55c697556a71
oai_identifier_str oai:ojs.spog:article/561
network_acronym_str 2304-5132
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
spelling Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartumExpulsión del dispositivo intrauterino T de cobre 380A insertado en el postalumbramiento y dentro de las 48 horas pospartoEscudero, FranciscoDelgadillo, L.Pérez, K.Muñante, M.OBJETIVE: To compare the rate of expulsion of intrauterine device (IUD) Copper T 380A inserted do postalumbramiento and within 48 hours after delivery. LOCATION: Department of Obstetrics Archbishop Loayza Hospital. MATERIALS AND METHODS: The study included 614 postpartum women who are TCu 380A IUD inserted after the birth or within 48 hours after birth, between 1992 and 1998. Statistical analysis was obtained frequencies, the test was applied chi square cumulative rates per 100 woman-years were determined using the life table. RESULTS: There were 176 IUD users postalumbramiento and 438 within 48 hours after birth. There was no significant difference between groups with respect to age, parity, marital status or previous use of contraceptive methods. Expulsion rates were higher at 3, 6 and 12 months follow-up users in whom TCu 380th dlu inserted within 48 hours postpartum (47.8, 49.6 and 55.3) compared to postalumbramienta. (20.1, 21.2 and 23.5), with statistically significant difference (p <0.0001). The expulsion was less common in large users multiparous, regardless of time of insertion (p <0.002). CONCLUSIONS: The rate of removal of DLU TCu 380A inserted after birth is lower in the postalumbramiento compared to 48 hours after birth and the expulsion of the IUD TCu 380A is lower if the users are large multiparous, regardless of the time of insertion.OBJETIVO: Comparar la tasa de expulsión del dispositivo intrauterino (DIU) T de cobre 380A inserta do postalumbramiento y en las 48 horas posteriores al parto. LUGAR: Servicio de Obstetricia del Hospital Arzobispo Loayza. MATERIAL Y MÉTODOS: El estudio incluyó 614 puérperas a quienes se les insertó el DIU TCu 380A luego del alumbramiento o dentro de las 48 horas posparto, entre los años 1992 y 1998. Para el análisis estadístico se obtuvo las frecuencias, se aplicó la prueba de chi cuadrado y las tasas acumulativas por 100 mujeres-años fueron determinadas empleando la tabla de vida. RESULTADOS: Hubo 176 usuarias del DIU postalumbramiento y 438 dentro de las 48 horas posparto. No existió diferencia significativa entre los grupos con relación a la edad, paridad, estado civil ni uso previo de métodos anticonceptivos. Las tasas de expulsión fueron mayores a los 3, 6 y 12 meses de seguimiento en las usuarias en quienes se insertó el DlU TCu 380ª durante las 48 horas posparto (47,8, 49,6 y 55,3) en comparación al postalumbramienta. (20,1, 21,2 y 23,5), con diferencia estadísticamente significativa (p< 0,0001).  La expulsión fue menos frecuente en las usuarias grandes multíparas, independiente del momento de inserción (p<0,002). CONCLUSIONES: La tasa de expulsión del DlU TCu 380A insertado después del parto es menor en el postalumbramiento comparada con las de 48 horas posparto y la expulsión del DIU Tcu 380A es menor si las usuarias son grandes multíparas, independientemente del momento de la inserción.Sociedad Peruana de Obstetricia y Ginecología2015-05-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/56110.31403/rpgo.v48i561Revista Peruana de Ginecología y Obstetricia; Vol. 48, Núm. 1 (2002); 42-452304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/561/523info:eu-repo/semantics/openAccess2021-04-19T15:51:38Zmail@mail.com -
dc.title.none.fl_str_mv Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
Expulsión del dispositivo intrauterino T de cobre 380A insertado en el postalumbramiento y dentro de las 48 horas posparto
title Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
spellingShingle Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
Escudero, Francisco
title_short Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
title_full Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
title_fullStr Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
title_full_unstemmed Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
title_sort Expulsion of the Copper- T 380A intrauterine device inserted immediately after delivery and within 48 hours postpartum
dc.creator.none.fl_str_mv Escudero, Francisco
Delgadillo, L.
Pérez, K.
Muñante, M.
author Escudero, Francisco
author_facet Escudero, Francisco
Delgadillo, L.
Pérez, K.
Muñante, M.
author_role author
author2 Delgadillo, L.
Pérez, K.
Muñante, M.
author2_role author
author
author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv OBJETIVE: To compare the rate of expulsion of intrauterine device (IUD) Copper T 380A inserted do postalumbramiento and within 48 hours after delivery. LOCATION: Department of Obstetrics Archbishop Loayza Hospital. MATERIALS AND METHODS: The study included 614 postpartum women who are TCu 380A IUD inserted after the birth or within 48 hours after birth, between 1992 and 1998. Statistical analysis was obtained frequencies, the test was applied chi square cumulative rates per 100 woman-years were determined using the life table. RESULTS: There were 176 IUD users postalumbramiento and 438 within 48 hours after birth. There was no significant difference between groups with respect to age, parity, marital status or previous use of contraceptive methods. Expulsion rates were higher at 3, 6 and 12 months follow-up users in whom TCu 380th dlu inserted within 48 hours postpartum (47.8, 49.6 and 55.3) compared to postalumbramienta. (20.1, 21.2 and 23.5), with statistically significant difference (p <0.0001). The expulsion was less common in large users multiparous, regardless of time of insertion (p <0.002). CONCLUSIONS: The rate of removal of DLU TCu 380A inserted after birth is lower in the postalumbramiento compared to 48 hours after birth and the expulsion of the IUD TCu 380A is lower if the users are large multiparous, regardless of the time of insertion.
OBJETIVO: Comparar la tasa de expulsión del dispositivo intrauterino (DIU) T de cobre 380A inserta do postalumbramiento y en las 48 horas posteriores al parto. LUGAR: Servicio de Obstetricia del Hospital Arzobispo Loayza. MATERIAL Y MÉTODOS: El estudio incluyó 614 puérperas a quienes se les insertó el DIU TCu 380A luego del alumbramiento o dentro de las 48 horas posparto, entre los años 1992 y 1998. Para el análisis estadístico se obtuvo las frecuencias, se aplicó la prueba de chi cuadrado y las tasas acumulativas por 100 mujeres-años fueron determinadas empleando la tabla de vida. RESULTADOS: Hubo 176 usuarias del DIU postalumbramiento y 438 dentro de las 48 horas posparto. No existió diferencia significativa entre los grupos con relación a la edad, paridad, estado civil ni uso previo de métodos anticonceptivos. Las tasas de expulsión fueron mayores a los 3, 6 y 12 meses de seguimiento en las usuarias en quienes se insertó el DlU TCu 380ª durante las 48 horas posparto (47,8, 49,6 y 55,3) en comparación al postalumbramienta. (20,1, 21,2 y 23,5), con diferencia estadísticamente significativa (p< 0,0001).  La expulsión fue menos frecuente en las usuarias grandes multíparas, independiente del momento de inserción (p<0,002). CONCLUSIONES: La tasa de expulsión del DlU TCu 380A insertado después del parto es menor en el postalumbramiento comparada con las de 48 horas posparto y la expulsión del DIU Tcu 380A es menor si las usuarias son grandes multíparas, independientemente del momento de la inserción.
description OBJETIVE: To compare the rate of expulsion of intrauterine device (IUD) Copper T 380A inserted do postalumbramiento and within 48 hours after delivery. LOCATION: Department of Obstetrics Archbishop Loayza Hospital. MATERIALS AND METHODS: The study included 614 postpartum women who are TCu 380A IUD inserted after the birth or within 48 hours after birth, between 1992 and 1998. Statistical analysis was obtained frequencies, the test was applied chi square cumulative rates per 100 woman-years were determined using the life table. RESULTS: There were 176 IUD users postalumbramiento and 438 within 48 hours after birth. There was no significant difference between groups with respect to age, parity, marital status or previous use of contraceptive methods. Expulsion rates were higher at 3, 6 and 12 months follow-up users in whom TCu 380th dlu inserted within 48 hours postpartum (47.8, 49.6 and 55.3) compared to postalumbramienta. (20.1, 21.2 and 23.5), with statistically significant difference (p <0.0001). The expulsion was less common in large users multiparous, regardless of time of insertion (p <0.002). CONCLUSIONS: The rate of removal of DLU TCu 380A inserted after birth is lower in the postalumbramiento compared to 48 hours after birth and the expulsion of the IUD TCu 380A is lower if the users are large multiparous, regardless of the time of insertion.
publishDate 2015
dc.date.none.fl_str_mv 2015-05-15
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/561
10.31403/rpgo.v48i561
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/561
identifier_str_mv 10.31403/rpgo.v48i561
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/561/523
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 48, Núm. 1 (2002); 42-45
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1697484744142356480
score 13.905282
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).