Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy

Descripción del Articulo

Objective: To value the use of three 10 mm trocars and an adapted uterine manipulator in performing total laparoscopic hysterectomy (TLH). Design: Descriptive retrospective study. Setting: Gynecology and Obstetrics Service, Hospital III EsSalud, Puno, Peru. Participants: Patients with TLH indication...

Descripción completa

Detalles Bibliográficos
Autores: Portugal, Edward, Passano, Agustín, Condori, Esther, Dueñas, Daniela
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/214
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/214
Nivel de acceso:acceso abierto
id 2304-5132_79c145b0bd03f3b89f27c646a2543a66
oai_identifier_str oai:ojs.spog:article/214
network_acronym_str 2304-5132
repository_id_str .
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
spelling Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomyEXPERIENCIA EN LA UTILIZACIÓN DE TRES TRÓCARES Y UN MANIPULADOR UTERINO ADAPTADO, EN LA HISTERECTOMÍA TOTAL LAPAROSCÓPICAPortugal, EdwardPassano, AgustínCondori, EstherDueñas, DanielaObjective: To value the use of three 10 mm trocars and an adapted uterine manipulator in performing total laparoscopic hysterectomy (TLH). Design: Descriptive retrospective study. Setting: Gynecology and Obstetrics Service, Hospital III EsSalud, Puno, Peru. Participants: Patients with TLH indication. Interventions: In the period 2004-2010, total hysterectomy by laparoscopy was performed in 78 patients with TLH indication, using bipolar, monopolar y Liga Sure. Main outcome measures: Surgical technique evaluation, postoperative evaluation and complications. Results: From 78 operations programmed, two cases were converted to laparotomy due to vesical lesion and one due to tumor in broad ligament that prevented adequate access to the operative field. Average age was 41 to 45 years, hospitalization three days, and average duration of surgery 126 minutes. We had two cases of vesical lesions and one ureteral lesion. Conclusions: Three trocars TLH with adapted uterine manipulator is a safe procedure and technically feasible to be performed.Objetivo: Evaluar la utilización de tres trócares de 10 mm y un manipulador uterino adaptado, en la realización de la histerectomía laparoscópica total (HTL). Diseño: Estudio descriptivo retrospectivo. Institución: Servicio de Gíneco Obstetrícia, Hospital III EsSalud, Puno, Perú. Participantes: Pacientes con indicación de HTL. Intervenciones: En el periodo 2004 a 2010, se realizó histerectomía total por vía laparoscópica a 78 pacientes con indicación de HTL, con el uso de bipolar, monopolar y Liga Sure. Principales medidas de resultados: Evaluación de la técnica quirúrgica, evolución postoperatoria y complicaciones. Resultados: De las 78 operaciones programadas, en dos se tuvo que convertir a laparotomía por lesión vesical y en una por tumoración en el ligamento ancho, que impidió el acceso adecuado al campo operatorio. La edad promedio fue 41 a 45 años, el tiempo promedio de hospitalización tres días. La duración promedio de la operación fue 126 minutos. Se tuvo dos casos de lesión vesical y uno de lesión de uréter. Conclusiones: La HTL con el uso de tres trócares y el manipulador uterino adaptado es un procedimiento  seguro y técnicamente factible de ser realizado.Sociedad Peruana de Obstetricia y Ginecología2015-04-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/21410.31403/rpgo.v56i214Revista Peruana de Ginecología y Obstetricia; Vol. 56, Núm. 4 (2010); 294-3002304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/214/193info:eu-repo/semantics/openAccess2021-05-31T15:50:53Zmail@mail.com -
dc.title.none.fl_str_mv Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
EXPERIENCIA EN LA UTILIZACIÓN DE TRES TRÓCARES Y UN MANIPULADOR UTERINO ADAPTADO, EN LA HISTERECTOMÍA TOTAL LAPAROSCÓPICA
title Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
spellingShingle Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
Portugal, Edward
title_short Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
title_full Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
title_fullStr Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
title_full_unstemmed Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
title_sort Experience with use of three trocars and an adapted uterine manipulator in total laparoscopic hysterectomy
dc.creator.none.fl_str_mv Portugal, Edward
Passano, Agustín
Condori, Esther
Dueñas, Daniela
author Portugal, Edward
author_facet Portugal, Edward
Passano, Agustín
Condori, Esther
Dueñas, Daniela
author_role author
author2 Passano, Agustín
Condori, Esther
Dueñas, Daniela
author2_role author
author
author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv Objective: To value the use of three 10 mm trocars and an adapted uterine manipulator in performing total laparoscopic hysterectomy (TLH). Design: Descriptive retrospective study. Setting: Gynecology and Obstetrics Service, Hospital III EsSalud, Puno, Peru. Participants: Patients with TLH indication. Interventions: In the period 2004-2010, total hysterectomy by laparoscopy was performed in 78 patients with TLH indication, using bipolar, monopolar y Liga Sure. Main outcome measures: Surgical technique evaluation, postoperative evaluation and complications. Results: From 78 operations programmed, two cases were converted to laparotomy due to vesical lesion and one due to tumor in broad ligament that prevented adequate access to the operative field. Average age was 41 to 45 years, hospitalization three days, and average duration of surgery 126 minutes. We had two cases of vesical lesions and one ureteral lesion. Conclusions: Three trocars TLH with adapted uterine manipulator is a safe procedure and technically feasible to be performed.
Objetivo: Evaluar la utilización de tres trócares de 10 mm y un manipulador uterino adaptado, en la realización de la histerectomía laparoscópica total (HTL). Diseño: Estudio descriptivo retrospectivo. Institución: Servicio de Gíneco Obstetrícia, Hospital III EsSalud, Puno, Perú. Participantes: Pacientes con indicación de HTL. Intervenciones: En el periodo 2004 a 2010, se realizó histerectomía total por vía laparoscópica a 78 pacientes con indicación de HTL, con el uso de bipolar, monopolar y Liga Sure. Principales medidas de resultados: Evaluación de la técnica quirúrgica, evolución postoperatoria y complicaciones. Resultados: De las 78 operaciones programadas, en dos se tuvo que convertir a laparotomía por lesión vesical y en una por tumoración en el ligamento ancho, que impidió el acceso adecuado al campo operatorio. La edad promedio fue 41 a 45 años, el tiempo promedio de hospitalización tres días. La duración promedio de la operación fue 126 minutos. Se tuvo dos casos de lesión vesical y uno de lesión de uréter. Conclusiones: La HTL con el uso de tres trócares y el manipulador uterino adaptado es un procedimiento  seguro y técnicamente factible de ser realizado.
description Objective: To value the use of three 10 mm trocars and an adapted uterine manipulator in performing total laparoscopic hysterectomy (TLH). Design: Descriptive retrospective study. Setting: Gynecology and Obstetrics Service, Hospital III EsSalud, Puno, Peru. Participants: Patients with TLH indication. Interventions: In the period 2004-2010, total hysterectomy by laparoscopy was performed in 78 patients with TLH indication, using bipolar, monopolar y Liga Sure. Main outcome measures: Surgical technique evaluation, postoperative evaluation and complications. Results: From 78 operations programmed, two cases were converted to laparotomy due to vesical lesion and one due to tumor in broad ligament that prevented adequate access to the operative field. Average age was 41 to 45 years, hospitalization three days, and average duration of surgery 126 minutes. We had two cases of vesical lesions and one ureteral lesion. Conclusions: Three trocars TLH with adapted uterine manipulator is a safe procedure and technically feasible to be performed.
publishDate 2015
dc.date.none.fl_str_mv 2015-04-21
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/214
10.31403/rpgo.v56i214
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/214
identifier_str_mv 10.31403/rpgo.v56i214
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/214/193
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 56, Núm. 4 (2010); 294-300
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701289830969769984
score 13.887878
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).