The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity...

Descripción completa

Detalles Bibliográficos
Autores: Sánchez, Hugo, Rodríguez, Ferrer
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/1557
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557
Nivel de acceso:acceso abierto
id 2304-5132_7646a2ed4e5b8b8079160d181bd8212c
oai_identifier_str oai:ojs.spog:article/1557
network_acronym_str 2304-5132
repository_id_str .
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
spelling Location of the placenta by auscultation with dopplerLocalización de la placenta mediante la auscultación con DopplerSánchez, HugoRodríguez, FerrerThe ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions.La ultrasonografía ha resuelto el problema de la localización placentaria. Sin embargo el alto costo de la ecografía atenta contra su masificación. Pero dentro de esta técnica contamos con equipos que aprovechando el efecto Doppler, aíslan la reflexión acústica con notable ventaja económica y sencillez en el manejo que permite su alta difusión. En un principio el Doppler se empleó para captar el ruido cardiaco fetal. Además de este sonido, con el instrumento se aprecian otros dentro de los cuales destaca el soplo placentario. Al captarlo supusimos que era posible delimitar el contorno de la placenta cuya proyección dibujamos mediante el "mapeo" en la pared abdominal. A estas pacientes se les práctico el "mapeo" placentario lo que constituyó el diagnóstico preoperatorio. Dentro del acto quirúrgico, una vez extraído el feto, a través de la incisión uterina, manualmente corroboramos a que altura, en que lado y en que pared del útero se encontraba insertada la placenta antes de preceder a retirarla. La comparación de ambos hallazgos - pre e intraoperatorio- , demostró la certeza de este procedimiento, registrándose una alta significación estadística.Sociedad Peruana de Obstetricia y Ginecología2015-07-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/155710.31403/rpgo.v37i1557Revista Peruana de Ginecología y Obstetricia; Vol. 37, Núm. 11 (1991); 20-292304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557/pdf_149info:eu-repo/semantics/openAccess2021-05-31T15:50:44Zmail@mail.com -
dc.title.none.fl_str_mv Location of the placenta by auscultation with doppler
Localización de la placenta mediante la auscultación con Doppler
title Location of the placenta by auscultation with doppler
spellingShingle Location of the placenta by auscultation with doppler
Sánchez, Hugo
title_short Location of the placenta by auscultation with doppler
title_full Location of the placenta by auscultation with doppler
title_fullStr Location of the placenta by auscultation with doppler
title_full_unstemmed Location of the placenta by auscultation with doppler
title_sort Location of the placenta by auscultation with doppler
dc.creator.none.fl_str_mv Sánchez, Hugo
Rodríguez, Ferrer
author Sánchez, Hugo
author_facet Sánchez, Hugo
Rodríguez, Ferrer
author_role author
author2 Rodríguez, Ferrer
author2_role author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions.
La ultrasonografía ha resuelto el problema de la localización placentaria. Sin embargo el alto costo de la ecografía atenta contra su masificación. Pero dentro de esta técnica contamos con equipos que aprovechando el efecto Doppler, aíslan la reflexión acústica con notable ventaja económica y sencillez en el manejo que permite su alta difusión. En un principio el Doppler se empleó para captar el ruido cardiaco fetal. Además de este sonido, con el instrumento se aprecian otros dentro de los cuales destaca el soplo placentario. Al captarlo supusimos que era posible delimitar el contorno de la placenta cuya proyección dibujamos mediante el "mapeo" en la pared abdominal. A estas pacientes se les práctico el "mapeo" placentario lo que constituyó el diagnóstico preoperatorio. Dentro del acto quirúrgico, una vez extraído el feto, a través de la incisión uterina, manualmente corroboramos a que altura, en que lado y en que pared del útero se encontraba insertada la placenta antes de preceder a retirarla. La comparación de ambos hallazgos - pre e intraoperatorio- , demostró la certeza de este procedimiento, registrándose una alta significación estadística.
description The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions.
publishDate 2015
dc.date.none.fl_str_mv 2015-07-26
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557
10.31403/rpgo.v37i1557
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557
identifier_str_mv 10.31403/rpgo.v37i1557
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557/pdf_149
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 37, Núm. 11 (1991); 20-29
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701289829854085120
score 13.945474
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).