Location of the placenta by auscultation with doppler
Descripción del Articulo
The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2015 |
| Institución: | Sociedad Peruana de Obstetricia y Ginecología |
| Repositorio: | Revista SPOG - Revista Peruana de Ginecología y Obstetricia |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.spog:article/1557 |
| Enlace del recurso: | http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557 |
| Nivel de acceso: | acceso abierto |
| id |
2304-5132_7646a2ed4e5b8b8079160d181bd8212c |
|---|---|
| oai_identifier_str |
oai:ojs.spog:article/1557 |
| network_acronym_str |
2304-5132 |
| repository_id_str |
. |
| network_name_str |
Revista SPOG - Revista Peruana de Ginecología y Obstetricia |
| spelling |
Location of the placenta by auscultation with dopplerLocalización de la placenta mediante la auscultación con DopplerSánchez, HugoRodríguez, FerrerThe ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions.La ultrasonografía ha resuelto el problema de la localización placentaria. Sin embargo el alto costo de la ecografía atenta contra su masificación. Pero dentro de esta técnica contamos con equipos que aprovechando el efecto Doppler, aíslan la reflexión acústica con notable ventaja económica y sencillez en el manejo que permite su alta difusión. En un principio el Doppler se empleó para captar el ruido cardiaco fetal. Además de este sonido, con el instrumento se aprecian otros dentro de los cuales destaca el soplo placentario. Al captarlo supusimos que era posible delimitar el contorno de la placenta cuya proyección dibujamos mediante el "mapeo" en la pared abdominal. A estas pacientes se les práctico el "mapeo" placentario lo que constituyó el diagnóstico preoperatorio. Dentro del acto quirúrgico, una vez extraído el feto, a través de la incisión uterina, manualmente corroboramos a que altura, en que lado y en que pared del útero se encontraba insertada la placenta antes de preceder a retirarla. La comparación de ambos hallazgos - pre e intraoperatorio- , demostró la certeza de este procedimiento, registrándose una alta significación estadística.Sociedad Peruana de Obstetricia y Ginecología2015-07-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/155710.31403/rpgo.v37i1557Revista Peruana de Ginecología y Obstetricia; Vol. 37, Núm. 11 (1991); 20-292304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557/pdf_149info:eu-repo/semantics/openAccess2021-05-31T15:50:44Zmail@mail.com - |
| dc.title.none.fl_str_mv |
Location of the placenta by auscultation with doppler Localización de la placenta mediante la auscultación con Doppler |
| title |
Location of the placenta by auscultation with doppler |
| spellingShingle |
Location of the placenta by auscultation with doppler Sánchez, Hugo |
| title_short |
Location of the placenta by auscultation with doppler |
| title_full |
Location of the placenta by auscultation with doppler |
| title_fullStr |
Location of the placenta by auscultation with doppler |
| title_full_unstemmed |
Location of the placenta by auscultation with doppler |
| title_sort |
Location of the placenta by auscultation with doppler |
| dc.creator.none.fl_str_mv |
Sánchez, Hugo Rodríguez, Ferrer |
| author |
Sánchez, Hugo |
| author_facet |
Sánchez, Hugo Rodríguez, Ferrer |
| author_role |
author |
| author2 |
Rodríguez, Ferrer |
| author2_role |
author |
| dc.contributor.none.fl_str_mv |
|
| dc.description.none.fl_txt_mv |
The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions. La ultrasonografía ha resuelto el problema de la localización placentaria. Sin embargo el alto costo de la ecografía atenta contra su masificación. Pero dentro de esta técnica contamos con equipos que aprovechando el efecto Doppler, aíslan la reflexión acústica con notable ventaja económica y sencillez en el manejo que permite su alta difusión. En un principio el Doppler se empleó para captar el ruido cardiaco fetal. Además de este sonido, con el instrumento se aprecian otros dentro de los cuales destaca el soplo placentario. Al captarlo supusimos que era posible delimitar el contorno de la placenta cuya proyección dibujamos mediante el "mapeo" en la pared abdominal. A estas pacientes se les práctico el "mapeo" placentario lo que constituyó el diagnóstico preoperatorio. Dentro del acto quirúrgico, una vez extraído el feto, a través de la incisión uterina, manualmente corroboramos a que altura, en que lado y en que pared del útero se encontraba insertada la placenta antes de preceder a retirarla. La comparación de ambos hallazgos - pre e intraoperatorio- , demostró la certeza de este procedimiento, registrándose una alta significación estadística. |
| description |
The ultrasound has solved the problem of the placentae localization, Still the high cost of ecography attempts its massification. But in this technique we count with equipments that taking advantage of the. Doppler effect inolate the acoustic reflection with notable economic advantage and simplicity in its management that also permits its high diffusion. In the beginning Doppler was used to get cardiac sound of the fetus. Besides this sound, we can appreciate others with this instrument where the placentae blow is an important one. While getting it, we supposed that it was possible to delimit the placentae contour which projection was drawn on the abdominal wall by "map out". The investigation has been taken in the Hospital Docente of Trujillo in a group of 50 pregnants that for got surgical interventions. |
| publishDate |
2015 |
| dc.date.none.fl_str_mv |
2015-07-26 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557 10.31403/rpgo.v37i1557 |
| url |
http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557 |
| identifier_str_mv |
10.31403/rpgo.v37i1557 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/1557/pdf_149 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Sociedad Peruana de Obstetricia y Ginecología |
| publisher.none.fl_str_mv |
Sociedad Peruana de Obstetricia y Ginecología |
| dc.source.none.fl_str_mv |
Revista Peruana de Ginecología y Obstetricia; Vol. 37, Núm. 11 (1991); 20-29 2304-5132 2304-5124 reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia instname:Sociedad Peruana de Obstetricia y Ginecología instacron:SPOG |
| reponame_str |
Revista SPOG - Revista Peruana de Ginecología y Obstetricia |
| collection |
Revista SPOG - Revista Peruana de Ginecología y Obstetricia |
| instname_str |
Sociedad Peruana de Obstetricia y Ginecología |
| instacron_str |
SPOG |
| institution |
SPOG |
| repository.name.fl_str_mv |
-
|
| repository.mail.fl_str_mv |
mail@mail.com |
| _version_ |
1701289829854085120 |
| score |
13.945474 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).