Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool

Descripción del Articulo

Objective: To evaluate the flow of the superior mesenteric artery and vein both by Doppler flowmetry and simultaneously, in normal controls and in cases of gastroschisis, as additional prognostic criteria. Methods: The venous/arterial index was determined by Doppler flowmetry; reference values for t...

Descripción completa

Detalles Bibliográficos
Autores: Sosa Olavarría, Alberto, Larrazábal, Natasha, Martínez de Mora, Ydimar, Ledezma del Corral, Juan, Morillo Jr., Jiver, Morillo Ochoa, Jiver
Formato: artículo
Fecha de Publicación:2019
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.spog:article/2203
Enlace del recurso:http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/2203
Nivel de acceso:acceso abierto
id 2304-5132_1a960716b4f630ae703fe4fc3fbec09a
oai_identifier_str oai:ojs.spog:article/2203
network_acronym_str 2304-5132
repository_id_str .
network_name_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
dc.title.none.fl_str_mv Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
Índice vena/arteria de vasos mesentéricos en casos de gastrosquisis: nueva herramienta pronóstica
title Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
spellingShingle Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
Sosa Olavarría, Alberto
title_short Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
title_full Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
title_fullStr Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
title_full_unstemmed Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
title_sort Mesenteric venous/arterial index in gastroschisis cases: a new prognostic tool
dc.creator.none.fl_str_mv Sosa Olavarría, Alberto
Larrazábal, Natasha
Martínez de Mora, Ydimar
Ledezma del Corral, Juan
Morillo Jr., Jiver
Morillo Ochoa, Jiver
author Sosa Olavarría, Alberto
author_facet Sosa Olavarría, Alberto
Larrazábal, Natasha
Martínez de Mora, Ydimar
Ledezma del Corral, Juan
Morillo Jr., Jiver
Morillo Ochoa, Jiver
author_role author
author2 Larrazábal, Natasha
Martínez de Mora, Ydimar
Ledezma del Corral, Juan
Morillo Jr., Jiver
Morillo Ochoa, Jiver
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv

dc.description.none.fl_txt_mv Objective: To evaluate the flow of the superior mesenteric artery and vein both by Doppler flowmetry and simultaneously, in normal controls and in cases of gastroschisis, as additional prognostic criteria. Methods: The venous/arterial index was determined by Doppler flowmetry; reference values for the superior mesenteric vessels were obtained from a group of 60 healthy fetuses of 30 to 34 weeks and 15 cases of gastroschisis. The flow rate wave (FRW) was obtained simultaneously from both the superior mesenteric artery and vein with an angle of insonation less than 60°; the vein velocity was divided by the systolic peak of the artery and the percentage index was calculated based on the velocity of both vessels. The equipment used was a Mylab™Twice from Esaote with a 3.5 MHz convex probe. Results: The superior mesenteric venous/arterial index value in the control group was 26% ± 6 (2SD). In 12 cases of gastroschisis, the index remained within the reference values, with favorable prognosis for primary reduction (9 with Svelitza technique and 3 with immediate neonatal primary reduction). In three cases, the venous/arterial index was below 20% (1%, 14% and 16% respectively), with unfavorable results; the worst case, where no venous flow was detected, required wide resection, presented short bowel syndrome and died at 6 months. Conclusions: The perfusion index of the eviscerated bowel, studied by the percentage between vein velocity and maximum mesenteric artery velocity, could have prognostic value for the flow conditions of afferent and efferent intestinal loops in gastroschisis.
Objetivo. Evaluar mediante flujometría Doppler y de manera simultánea el flujo de la arteria y vena mesentérica superior en casos normales y en aquellos portadores de gastrosquisis, como criterio adicional en el pronóstico. Métodos. Se determinó mediante flujometría Doppler el índice venoso/arterial, obteniendo los valores de referencia de los vasos mesentéricos superiores, en un grupo de 60 fetos sanos con 30 a 34 semanas de gestación y 15 casos portadores de gastrosquisis. Se obtuvo la onda de velocidad de flujo (OVF) simultáneamente de la arteria y de la vena mesentérica superior, con ángulo de insonación menor a 60°; la velocidad de la vena fue dividida entre el pico sistólico de la arteria y calculado el índice porcentual entre las velocidades de ambos vasos. El equipo utilizado fue un MyLab Twice de Esaote con transductor convexo de 3,5 MHz. Resultados. El valor del índice veno/arterial de los vasos mesentéricos superiores en el grupo control fue 26% ± 6 (2DE). En 12 casos de gastrosquisis, el índice se mantuvo dentro de los valores de referencia y con índice pronóstico favorable para reducción primaria (9 con técnica de Svelitza y 3 con reducción primaria neonatal inmediata) y, en tres casos, el índice porcentual veno/arterial se encontró por debajo del 20%, (1%, 14% y 16%), con resultados desfavorables. En el caso con mayor compromiso, no pudo detectarse flujo venoso y requirió de resección amplia, con síndrome de intestino corto y fallecimiento a los 6 meses. Conclusiones. El índice de perfusión de las asas intestinales evisceradas, estudiado mediante la relación porcentual entre las velocidades de la vena y velocidad máxima de la arteria mesentérica superior, podría ser considerada como un complemento pronóstico en las condiciones de flujos aferentes y eferentes en que se encuentran dichas asas, en los casos de gastrosquisis.
description Objective: To evaluate the flow of the superior mesenteric artery and vein both by Doppler flowmetry and simultaneously, in normal controls and in cases of gastroschisis, as additional prognostic criteria. Methods: The venous/arterial index was determined by Doppler flowmetry; reference values for the superior mesenteric vessels were obtained from a group of 60 healthy fetuses of 30 to 34 weeks and 15 cases of gastroschisis. The flow rate wave (FRW) was obtained simultaneously from both the superior mesenteric artery and vein with an angle of insonation less than 60°; the vein velocity was divided by the systolic peak of the artery and the percentage index was calculated based on the velocity of both vessels. The equipment used was a Mylab™Twice from Esaote with a 3.5 MHz convex probe. Results: The superior mesenteric venous/arterial index value in the control group was 26% ± 6 (2SD). In 12 cases of gastroschisis, the index remained within the reference values, with favorable prognosis for primary reduction (9 with Svelitza technique and 3 with immediate neonatal primary reduction). In three cases, the venous/arterial index was below 20% (1%, 14% and 16% respectively), with unfavorable results; the worst case, where no venous flow was detected, required wide resection, presented short bowel syndrome and died at 6 months. Conclusions: The perfusion index of the eviscerated bowel, studied by the percentage between vein velocity and maximum mesenteric artery velocity, could have prognostic value for the flow conditions of afferent and efferent intestinal loops in gastroschisis.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-02
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/2203
10.31403/rpgo.v65i2203
url http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/2203
identifier_str_mv 10.31403/rpgo.v65i2203
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.spog.org.pe/web/revista/index.php/RPGO/article/view/2203/pdf
dc.rights.none.fl_str_mv Copyright (c) 2019 Revista Peruana de Ginecología y Obstetricia
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2019 Revista Peruana de Ginecología y Obstetricia
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv Revista Peruana de Ginecología y Obstetricia; Vol. 65, Núm. 4 (2019); 449-454
2304-5132
2304-5124
reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
reponame_str Revista SPOG - Revista Peruana de Ginecología y Obstetricia
collection Revista SPOG - Revista Peruana de Ginecología y Obstetricia
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701289835786928128
spelling Mesenteric venous/arterial index in gastroschisis cases: a new prognostic toolÍndice vena/arteria de vasos mesentéricos en casos de gastrosquisis: nueva herramienta pronósticaSosa Olavarría, AlbertoLarrazábal, NatashaMartínez de Mora, YdimarLedezma del Corral, JuanMorillo Jr., JiverMorillo Ochoa, JiverObjective: To evaluate the flow of the superior mesenteric artery and vein both by Doppler flowmetry and simultaneously, in normal controls and in cases of gastroschisis, as additional prognostic criteria. Methods: The venous/arterial index was determined by Doppler flowmetry; reference values for the superior mesenteric vessels were obtained from a group of 60 healthy fetuses of 30 to 34 weeks and 15 cases of gastroschisis. The flow rate wave (FRW) was obtained simultaneously from both the superior mesenteric artery and vein with an angle of insonation less than 60°; the vein velocity was divided by the systolic peak of the artery and the percentage index was calculated based on the velocity of both vessels. The equipment used was a Mylab™Twice from Esaote with a 3.5 MHz convex probe. Results: The superior mesenteric venous/arterial index value in the control group was 26% ± 6 (2SD). In 12 cases of gastroschisis, the index remained within the reference values, with favorable prognosis for primary reduction (9 with Svelitza technique and 3 with immediate neonatal primary reduction). In three cases, the venous/arterial index was below 20% (1%, 14% and 16% respectively), with unfavorable results; the worst case, where no venous flow was detected, required wide resection, presented short bowel syndrome and died at 6 months. Conclusions: The perfusion index of the eviscerated bowel, studied by the percentage between vein velocity and maximum mesenteric artery velocity, could have prognostic value for the flow conditions of afferent and efferent intestinal loops in gastroschisis.Objetivo. Evaluar mediante flujometría Doppler y de manera simultánea el flujo de la arteria y vena mesentérica superior en casos normales y en aquellos portadores de gastrosquisis, como criterio adicional en el pronóstico. Métodos. Se determinó mediante flujometría Doppler el índice venoso/arterial, obteniendo los valores de referencia de los vasos mesentéricos superiores, en un grupo de 60 fetos sanos con 30 a 34 semanas de gestación y 15 casos portadores de gastrosquisis. Se obtuvo la onda de velocidad de flujo (OVF) simultáneamente de la arteria y de la vena mesentérica superior, con ángulo de insonación menor a 60°; la velocidad de la vena fue dividida entre el pico sistólico de la arteria y calculado el índice porcentual entre las velocidades de ambos vasos. El equipo utilizado fue un MyLab Twice de Esaote con transductor convexo de 3,5 MHz. Resultados. El valor del índice veno/arterial de los vasos mesentéricos superiores en el grupo control fue 26% ± 6 (2DE). En 12 casos de gastrosquisis, el índice se mantuvo dentro de los valores de referencia y con índice pronóstico favorable para reducción primaria (9 con técnica de Svelitza y 3 con reducción primaria neonatal inmediata) y, en tres casos, el índice porcentual veno/arterial se encontró por debajo del 20%, (1%, 14% y 16%), con resultados desfavorables. En el caso con mayor compromiso, no pudo detectarse flujo venoso y requirió de resección amplia, con síndrome de intestino corto y fallecimiento a los 6 meses. Conclusiones. El índice de perfusión de las asas intestinales evisceradas, estudiado mediante la relación porcentual entre las velocidades de la vena y velocidad máxima de la arteria mesentérica superior, podría ser considerada como un complemento pronóstico en las condiciones de flujos aferentes y eferentes en que se encuentran dichas asas, en los casos de gastrosquisis.Sociedad Peruana de Obstetricia y Ginecología2019-10-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/220310.31403/rpgo.v65i2203Revista Peruana de Ginecología y Obstetricia; Vol. 65, Núm. 4 (2019); 449-4542304-51322304-5124reponame:Revista SPOG - Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://www.spog.org.pe/web/revista/index.php/RPGO/article/view/2203/pdfCopyright (c) 2019 Revista Peruana de Ginecología y Obstetriciainfo:eu-repo/semantics/openAccess2021-05-31T15:51:30Zmail@mail.com -
score 13.924177
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).