ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING

Descripción del Articulo

222Rn is formed by the decay of 226Ra , then decays into 218Po and 214Po . Po ions electrostatically produced can be collected using a camera with a polarized high voltage then decays 218Po 214Pb particles emitting at 6.003 keV and thereafter decays 214Po 210Pb emitting particles at 7.687 keV. By me...

Descripción completa

Detalles Bibliográficos
Autores: Baltuano E., O., Munive S., M., Martinez G., J., Gonzales V., S., Hernanández P., Y., Solis V., J. L.
Formato: artículo
Fecha de Publicación:2011
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - Revista Peruana de Química e Ingeniería Química
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4607
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607
Nivel de acceso:acceso abierto
Materia:PIN diode
Radon
microcontroller.
Diodo PIN
Radón
microcontrolador.
id 1609-7599_2c80dfedcc7ef53bbc79e79c69962ded
oai_identifier_str oai:ojs.csi.unmsm:article/4607
network_acronym_str 1609-7599
repository_id_str .
network_name_str Revista UNMSM - Revista Peruana de Química e Ingeniería Química
dc.title.none.fl_str_mv ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
DESARROLLO DE UN SISTEMA ECONÓMICO PARA MONITOREAR RADÓN EN INSTALACIONES INDUSTRIALES Y DE VIVIENDA
title ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
spellingShingle ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
Baltuano E., O.
PIN diode
Radon
microcontroller.
Diodo PIN
Radón
microcontrolador.
title_short ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
title_full ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
title_fullStr ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
title_full_unstemmed ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
title_sort ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSING
dc.creator.none.fl_str_mv Baltuano E., O.
Munive S., M.
Martinez G., J.
Gonzales V., S.
Hernanández P., Y.
Solis V., J. L.
author Baltuano E., O.
author_facet Baltuano E., O.
Munive S., M.
Martinez G., J.
Gonzales V., S.
Hernanández P., Y.
Solis V., J. L.
author_role author
author2 Munive S., M.
Martinez G., J.
Gonzales V., S.
Hernanández P., Y.
Solis V., J. L.
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv PIN diode
Radon
microcontroller.
Diodo PIN
Radón
microcontrolador.
topic PIN diode
Radon
microcontroller.
Diodo PIN
Radón
microcontrolador.
dc.description.none.fl_txt_mv 222Rn is formed by the decay of 226Ra , then decays into 218Po and 214Po . Po ions electrostatically produced can be collected using a camera with a polarized high voltage then decays 218Po 214Pb particles emitting at 6.003 keV and thereafter decays 214Po 210Pb emitting particles at 7.687 keV. By measuring the concentration of these alpha particles in the camera can determine the concentration of radon in the air in an indirect way . The prototype has been developed using a measuring chamber 2 L stainless steel of a S3204 -09 PIN diode ( Hamamatsu ) bare body as alpha-particle detector . The camera and diode are polarized with a source of high voltage ( +500 V ) to collect ions and detect Po alpha particles that are then produced in the decay chain . Operations and digital functions are implemented on a PIC18F4550 microcontroller and the device has an internal USB module communication for transferring data to a PC. The configuration of basic parameters is done through a laptop via USB port. Calibration was performed using a system Alfaguard sales team and an area where uranium has been buried for a source of radon , measurements were made at different points with different concentrations of radon. It has been possible to monitor the radon ventilated offices closed and is observed as the variation of radon over several days .
El 222Rn se forma por la desintegración del 226Ra, y luego se desintegra en 218Po y 214Po. Los iones de Po producidos se pueden colectar electrostáticamente usando una cámara polarizada con una fuente de alta tensión, luego el 218Po decae a 214Pb emitiendo particulas a de 6.003 keV y posteriormente el 214Po decae a 210Pb emitiendo partículas a de 7.687 keV. Al medir la concentración de estas partículas alfas en la cámara se puede determinar la concentración del radón en el aire de una forma indirecta. El prototipo que se ha desarrollando utiliza una cámara de medida de acero inoxidable de 2 L con un diodo PIN S3204-09 (Hamamatsu) de cuerpo desnudo como detector de partículas alfa. La cámara y el diodo están polarizados con una fuente de alta tensión (+500 V) para colectar los iones de Po y detectar las partículas alfas que se producen luego en la cadena de decaimiento. Las operaciones y funciones digitales son implementadas sobre un microcontrolador PIC18F4550 y este dispositivo cuenta con un módulo de comunicación USB interno para realizar la transferencia de los datos a una PC. La configuración de los parámetros básicos de operación se realiza a través de una laptop por medio del puerto USB. Se ha realizado la calibración del sistema usando un equipo comercial Alfaguard y una zona donde se ha enterrado uranio para tener una fuente de radón, se han realizado las medidas en diferentes puntos con diferentes concentraciones de radón. Se ha logrado monitorear el radón en oficinas cerradas y ventiladas observándose como es la variación de radón a lo largo de varios días
description 222Rn is formed by the decay of 226Ra , then decays into 218Po and 214Po . Po ions electrostatically produced can be collected using a camera with a polarized high voltage then decays 218Po 214Pb particles emitting at 6.003 keV and thereafter decays 214Po 210Pb emitting particles at 7.687 keV. By measuring the concentration of these alpha particles in the camera can determine the concentration of radon in the air in an indirect way . The prototype has been developed using a measuring chamber 2 L stainless steel of a S3204 -09 PIN diode ( Hamamatsu ) bare body as alpha-particle detector . The camera and diode are polarized with a source of high voltage ( +500 V ) to collect ions and detect Po alpha particles that are then produced in the decay chain . Operations and digital functions are implemented on a PIC18F4550 microcontroller and the device has an internal USB module communication for transferring data to a PC. The configuration of basic parameters is done through a laptop via USB port. Calibration was performed using a system Alfaguard sales team and an area where uranium has been buried for a source of radon , measurements were made at different points with different concentrations of radon. It has been possible to monitor the radon ventilated offices closed and is observed as the variation of radon over several days .
publishDate 2011
dc.date.none.fl_str_mv 2011-12-30
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607
url https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607/3686
dc.rights.none.fl_str_mv Derechos de autor 2011 O. Baltuano E., M. Munive S., J. Martinez G., S. Gonzales V., Y. Hernanández P., J. L. Solis V.
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2011 O. Baltuano E., M. Munive S., J. Martinez G., S. Gonzales V., Y. Hernanández P., J. L. Solis V.
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Revista Peruana de Química e Ingeniería Química; Vol 14 No 1 y 2 (2011); 73-80
Revista Peruana de Química e Ingeniería Química; Vol. 14 Núm. 1 y 2 (2011); 73-80
1609-7599
1726-2208
reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Química
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - Revista Peruana de Química e Ingeniería Química
collection Revista UNMSM - Revista Peruana de Química e Ingeniería Química
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701389115497381888
spelling ECONOMIC DEVELOPMENT OF A SYSTEM TO MONITOR RADON IN INDUSTRIAL FACILITIES AND HOUSINGDESARROLLO DE UN SISTEMA ECONÓMICO PARA MONITOREAR RADÓN EN INSTALACIONES INDUSTRIALES Y DE VIVIENDABaltuano E., O.Munive S., M.Martinez G., J.Gonzales V., S.Hernanández P., Y.Solis V., J. L.PIN diodeRadonmicrocontroller.Diodo PINRadónmicrocontrolador.222Rn is formed by the decay of 226Ra , then decays into 218Po and 214Po . Po ions electrostatically produced can be collected using a camera with a polarized high voltage then decays 218Po 214Pb particles emitting at 6.003 keV and thereafter decays 214Po 210Pb emitting particles at 7.687 keV. By measuring the concentration of these alpha particles in the camera can determine the concentration of radon in the air in an indirect way . The prototype has been developed using a measuring chamber 2 L stainless steel of a S3204 -09 PIN diode ( Hamamatsu ) bare body as alpha-particle detector . The camera and diode are polarized with a source of high voltage ( +500 V ) to collect ions and detect Po alpha particles that are then produced in the decay chain . Operations and digital functions are implemented on a PIC18F4550 microcontroller and the device has an internal USB module communication for transferring data to a PC. The configuration of basic parameters is done through a laptop via USB port. Calibration was performed using a system Alfaguard sales team and an area where uranium has been buried for a source of radon , measurements were made at different points with different concentrations of radon. It has been possible to monitor the radon ventilated offices closed and is observed as the variation of radon over several days .El 222Rn se forma por la desintegración del 226Ra, y luego se desintegra en 218Po y 214Po. Los iones de Po producidos se pueden colectar electrostáticamente usando una cámara polarizada con una fuente de alta tensión, luego el 218Po decae a 214Pb emitiendo particulas a de 6.003 keV y posteriormente el 214Po decae a 210Pb emitiendo partículas a de 7.687 keV. Al medir la concentración de estas partículas alfas en la cámara se puede determinar la concentración del radón en el aire de una forma indirecta. El prototipo que se ha desarrollando utiliza una cámara de medida de acero inoxidable de 2 L con un diodo PIN S3204-09 (Hamamatsu) de cuerpo desnudo como detector de partículas alfa. La cámara y el diodo están polarizados con una fuente de alta tensión (+500 V) para colectar los iones de Po y detectar las partículas alfas que se producen luego en la cadena de decaimiento. Las operaciones y funciones digitales son implementadas sobre un microcontrolador PIC18F4550 y este dispositivo cuenta con un módulo de comunicación USB interno para realizar la transferencia de los datos a una PC. La configuración de los parámetros básicos de operación se realiza a través de una laptop por medio del puerto USB. Se ha realizado la calibración del sistema usando un equipo comercial Alfaguard y una zona donde se ha enterrado uranio para tener una fuente de radón, se han realizado las medidas en diferentes puntos con diferentes concentraciones de radón. Se ha logrado monitorear el radón en oficinas cerradas y ventiladas observándose como es la variación de radón a lo largo de varios díasUniversidad Nacional Mayor de San Marcos2011-12-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607Revista Peruana de Química e Ingeniería Química; Vol 14 No 1 y 2 (2011); 73-80Revista Peruana de Química e Ingeniería Química; Vol. 14 Núm. 1 y 2 (2011); 73-801609-75991726-2208reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Químicainstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4607/3686Derechos de autor 2011 O. Baltuano E., M. Munive S., J. Martinez G., S. Gonzales V., Y. Hernanández P., J. L. Solis V.http://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T18:10:45Zmail@mail.com -
score 13.919774
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).