Biodisk study as domestic wastewater secundary treatment

Descripción del Articulo

Laboratory model RBC system was designed as secondary treatment of an UASB reactor effluent. RBC System was built with two stages in series, each stage with effective volume of 81 liters and seven (07) PVC disks of 60 cm diameter with a total effective area of ​​7.92 m2. RBC system operated at a con...

Descripción completa

Detalles Bibliográficos
Autor: Delgado, Gustavo
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional de Ingeniería
Repositorio:Revista UNI - Tecnia
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/545
Enlace del recurso:http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545
Nivel de acceso:acceso abierto
Materia:Biodiscos
UASB
DBO
Aguas residuales
id 0375-7765_7ce3dc9adcd8a3d8c36792462f94fd8f
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/545
network_acronym_str 0375-7765
repository_id_str .
network_name_str Revista UNI - Tecnia
spelling Biodisk study as domestic wastewater secundary treatmentEstudio de biodiscos como tratamiento secundario de aguas residuales domésticasDelgado, GustavoBiodiscosUASBDBOAguas residualesLaboratory model RBC system was designed as secondary treatment of an UASB reactor effluent. RBC System was built with two stages in series, each stage with effective volume of 81 liters and seven (07) PVC disks of 60 cm diameter with a total effective area of ​​7.92 m2. RBC system operated at a constant flow rate of 432 l / day (HRT of 4.50 hours) and was operated in two periods at different disk rotational speed (3 rpm for 4 months and 5 rpm for 3 months). The values ​​of BOD5, SST, Turbidity, pH and Temperature were measured. Moreover, the physical and microbiological biofilm characteristics were observed throughout the study period. RBC System achieved optimal degree of oxygenation, with an average value of 5.21 mg DO/ l just in the first stage. DOB5 Removal efficiency was 90% for 5 rpm of rotational speed and 78% for 3 rpm. Finally, the RBC system showed a better performance in terms of organic matter removal for 3 rpm rotational speed of. Moreover, it was found that two stages performance in series was higher than a single stage. The most representative biofilm microorganisms in first stage were protozoa ciliated swimmers or free and filamentous bacteria that had an excessive growth at second period. In the second stage, it was fixed ciliated protozoa, rotifers and unicellular and filamentous algae.Se diseñó un sistema de biodiscos a escala de laboratorio como tratamiento secundario de un efluente de un reactor UASB. El sistema se construyó con dos etapas en serie, cada etapa con un volumen efectivo de 81 litros y siete (07) discos de PVC de 60 cm de diámetro que hacían un área total efectiva de 7.92 m2. El sistema funcionó a un caudal constante de 432 l/día (TRH de 4.50 horas por etapa) y se evaluó en dos períodos de operación variando la velocidad de rotación de los discos (3 rpm durante 3 meses y 5 rpm durante 3 meses).  Se midieron los valores de DBO5, SST, Turbiedad, pH y Temperatura. Además se observaron las características físicas y microbiológicas de la biopelícula durante todo el período de investigación. El sistema tuvo un grado óptimo de oxigenación, alcanzando solo en la primera etapa un valor promedio de 5.21 mg O2/l. La eficiencia de remoción promedio de la DBO5 fue del 90% para una velocidad de rotación de 3 rpm y del 78% para 5 rpm. Finalmente el sistema mostró un mejor desempeño en términos de remoción de materia orgánica para una velocidad de 3 rpm  Además, se comprobó que dos etapas en serie tuvieron un mejor rendimiento que una sola etapa. Los microorganismos más representativos de la biopelícula de la primera etapa fueron protozoarios ciliados nadadores o libres y las bacterias filamentosas que tuvieron un crecimiento excesivo para el segundo período. En la segunda etapa, fueron los protozoarios ciliados fijos, rotíferos y algas unicelulares y filamentosas.Universidad Nacional de Ingeniería2019-06-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionEnvironmental engineeringIngeniería Ambientalapplication/pdfaudio/mpegtext/htmlapplication/epub+ziphttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/54510.21754/tecnia.v29i1.545TECNIA; Vol 29 No 1 (2019)TECNIA; Vol. 29 Núm. 1 (2019)2309-04130375-7765reponame:Revista UNI - Tecniainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1019http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1038http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1076http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1078info:eu-repo/semantics/openAccess2021-05-29T15:55:42Zmail@mail.com -
dc.title.none.fl_str_mv Biodisk study as domestic wastewater secundary treatment
Estudio de biodiscos como tratamiento secundario de aguas residuales domésticas
title Biodisk study as domestic wastewater secundary treatment
spellingShingle Biodisk study as domestic wastewater secundary treatment
Delgado, Gustavo
Biodiscos
UASB
DBO
Aguas residuales
title_short Biodisk study as domestic wastewater secundary treatment
title_full Biodisk study as domestic wastewater secundary treatment
title_fullStr Biodisk study as domestic wastewater secundary treatment
title_full_unstemmed Biodisk study as domestic wastewater secundary treatment
title_sort Biodisk study as domestic wastewater secundary treatment
dc.creator.none.fl_str_mv Delgado, Gustavo
author Delgado, Gustavo
author_facet Delgado, Gustavo
author_role author
dc.subject.none.fl_str_mv Biodiscos
UASB
DBO
Aguas residuales
topic Biodiscos
UASB
DBO
Aguas residuales
dc.description.none.fl_txt_mv Laboratory model RBC system was designed as secondary treatment of an UASB reactor effluent. RBC System was built with two stages in series, each stage with effective volume of 81 liters and seven (07) PVC disks of 60 cm diameter with a total effective area of ​​7.92 m2. RBC system operated at a constant flow rate of 432 l / day (HRT of 4.50 hours) and was operated in two periods at different disk rotational speed (3 rpm for 4 months and 5 rpm for 3 months). The values ​​of BOD5, SST, Turbidity, pH and Temperature were measured. Moreover, the physical and microbiological biofilm characteristics were observed throughout the study period. RBC System achieved optimal degree of oxygenation, with an average value of 5.21 mg DO/ l just in the first stage. DOB5 Removal efficiency was 90% for 5 rpm of rotational speed and 78% for 3 rpm. Finally, the RBC system showed a better performance in terms of organic matter removal for 3 rpm rotational speed of. Moreover, it was found that two stages performance in series was higher than a single stage. The most representative biofilm microorganisms in first stage were protozoa ciliated swimmers or free and filamentous bacteria that had an excessive growth at second period. In the second stage, it was fixed ciliated protozoa, rotifers and unicellular and filamentous algae.
Se diseñó un sistema de biodiscos a escala de laboratorio como tratamiento secundario de un efluente de un reactor UASB. El sistema se construyó con dos etapas en serie, cada etapa con un volumen efectivo de 81 litros y siete (07) discos de PVC de 60 cm de diámetro que hacían un área total efectiva de 7.92 m2. El sistema funcionó a un caudal constante de 432 l/día (TRH de 4.50 horas por etapa) y se evaluó en dos períodos de operación variando la velocidad de rotación de los discos (3 rpm durante 3 meses y 5 rpm durante 3 meses).  Se midieron los valores de DBO5, SST, Turbiedad, pH y Temperatura. Además se observaron las características físicas y microbiológicas de la biopelícula durante todo el período de investigación. El sistema tuvo un grado óptimo de oxigenación, alcanzando solo en la primera etapa un valor promedio de 5.21 mg O2/l. La eficiencia de remoción promedio de la DBO5 fue del 90% para una velocidad de rotación de 3 rpm y del 78% para 5 rpm. Finalmente el sistema mostró un mejor desempeño en términos de remoción de materia orgánica para una velocidad de 3 rpm  Además, se comprobó que dos etapas en serie tuvieron un mejor rendimiento que una sola etapa. Los microorganismos más representativos de la biopelícula de la primera etapa fueron protozoarios ciliados nadadores o libres y las bacterias filamentosas que tuvieron un crecimiento excesivo para el segundo período. En la segunda etapa, fueron los protozoarios ciliados fijos, rotíferos y algas unicelulares y filamentosas.
description Laboratory model RBC system was designed as secondary treatment of an UASB reactor effluent. RBC System was built with two stages in series, each stage with effective volume of 81 liters and seven (07) PVC disks of 60 cm diameter with a total effective area of ​​7.92 m2. RBC system operated at a constant flow rate of 432 l / day (HRT of 4.50 hours) and was operated in two periods at different disk rotational speed (3 rpm for 4 months and 5 rpm for 3 months). The values ​​of BOD5, SST, Turbidity, pH and Temperature were measured. Moreover, the physical and microbiological biofilm characteristics were observed throughout the study period. RBC System achieved optimal degree of oxygenation, with an average value of 5.21 mg DO/ l just in the first stage. DOB5 Removal efficiency was 90% for 5 rpm of rotational speed and 78% for 3 rpm. Finally, the RBC system showed a better performance in terms of organic matter removal for 3 rpm rotational speed of. Moreover, it was found that two stages performance in series was higher than a single stage. The most representative biofilm microorganisms in first stage were protozoa ciliated swimmers or free and filamentous bacteria that had an excessive growth at second period. In the second stage, it was fixed ciliated protozoa, rotifers and unicellular and filamentous algae.
publishDate 2019
dc.date.none.fl_str_mv 2019-06-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Environmental engineering
Ingeniería Ambiental
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545
10.21754/tecnia.v29i1.545
url http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545
identifier_str_mv 10.21754/tecnia.v29i1.545
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1019
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1038
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1076
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/545/1078
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
audio/mpeg
text/html
application/epub+zip
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol 29 No 1 (2019)
TECNIA; Vol. 29 Núm. 1 (2019)
2309-0413
0375-7765
reponame:Revista UNI - Tecnia
instname:Universidad Nacional de Ingeniería
instacron:UNI
reponame_str Revista UNI - Tecnia
collection Revista UNI - Tecnia
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701108800354779136
score 13.896995
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).