Assessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoi...

Descripción completa

Detalles Bibliográficos
Autores: Huaco Cardenas, Guillermo David, Inga, Waldo, Camacho, Audry
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional de Ingeniería
Repositorio:Revista UNI - Tecnia
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/722
Enlace del recurso:http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722
Nivel de acceso:acceso abierto
Materia:Melt shop
Performance base design
Bridge crane
id 0375-7765_37e5b067ab017cfe67fc90c3b29f8a01
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/722
network_acronym_str 0375-7765
repository_id_str .
network_name_str Revista UNI - Tecnia
dc.title.none.fl_str_mv Seismic structural assessment of a 40 years old melt shop facility
title Seismic structural assessment of a 40 years old melt shop facility
spellingShingle Seismic structural assessment of a 40 years old melt shop facility
Huaco Cardenas, Guillermo David
Melt shop
Performance base design
Bridge crane
title_short Seismic structural assessment of a 40 years old melt shop facility
title_full Seismic structural assessment of a 40 years old melt shop facility
title_fullStr Seismic structural assessment of a 40 years old melt shop facility
title_full_unstemmed Seismic structural assessment of a 40 years old melt shop facility
title_sort Seismic structural assessment of a 40 years old melt shop facility
dc.creator.none.fl_str_mv Huaco Cardenas, Guillermo David
Inga, Waldo
Camacho, Audry
author Huaco Cardenas, Guillermo David
author_facet Huaco Cardenas, Guillermo David
Inga, Waldo
Camacho, Audry
author_role author
author2 Inga, Waldo
Camacho, Audry
author2_role author
author
dc.subject.none.fl_str_mv Melt shop
Performance base design
Bridge crane
topic Melt shop
Performance base design
Bridge crane
dc.description.none.fl_txt_mv Assessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoid possible economical losses if this facility stops its operations after any main seismic event. It is presented the structural assessment of the infrastructure of a melt shop facility, which it used for production of structural steel shapes. This infrastructure was built at the beginning of 80’s and it is located at near Pisco city in Peru. Reinforced concrete C columns and L beams make the frames of the structure and the rood is made by steel trusts. NDT and destructive tests were made for the reinforced concrete members as well of extraction of steel coupons from the roof trusts. Auscultation of foundation, reinforced concrete and steel structures were performed. It was found that several columns present damages such as spalling of cover, impact hits from heavy vehicles, which get in the interior of the facility. The roof presents metallic dust which was accumulated by the smelter operation. Heat of 50 Celsius degrees is the average temperature during the 20hours per day of operation time. Besides, capacity of several reinforced concrete columns and beams, and steel members of the roof is minor that their demands respectively according to Peru and international codes. The performance of the full structure of the melt shop including concrete and steel structures presents allowed drifts according seismic provisions, however this structure behaves on its nonlinear range under demands of Peru seismic code.
Assessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoid possible economical losses if this facility stops its operations after any main seismic event. It is presented the structural assessment of the infrastructure of a melt shop facility, which it used for production of structural steel shapes. This infrastructure was built at the beginning of 80’s and it is located at near Pisco city in Peru. Reinforced concrete C columns and L beams make the frames of the structure and the rood is made by steel trusts. NDT and destructive tests were made for the reinforced concrete members as well of extraction of steel coupons from the roof trusts. Auscultation of foundation, reinforced concrete and steel structures were performed. It was found that several columns present damages such as spalling of cover, impact hits from heavy vehicles, which get in the interior of the facility. The roof presents metallic dust which was accumulated by the smelter operation. Heat of 50 Celsius degrees is the average temperature during the 20hours per day of operation time. Besides, capacity of several reinforced concrete columns and beams, and steel members of the roof is minor that their demands respectively according to Peru and international codes. The performance of the full structure of the melt shop including concrete and steel structures presents allowed drifts according seismic provisions, however this structure behaves on its nonlinear range under demands of Peru seismic code.
description Assessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoid possible economical losses if this facility stops its operations after any main seismic event. It is presented the structural assessment of the infrastructure of a melt shop facility, which it used for production of structural steel shapes. This infrastructure was built at the beginning of 80’s and it is located at near Pisco city in Peru. Reinforced concrete C columns and L beams make the frames of the structure and the rood is made by steel trusts. NDT and destructive tests were made for the reinforced concrete members as well of extraction of steel coupons from the roof trusts. Auscultation of foundation, reinforced concrete and steel structures were performed. It was found that several columns present damages such as spalling of cover, impact hits from heavy vehicles, which get in the interior of the facility. The roof presents metallic dust which was accumulated by the smelter operation. Heat of 50 Celsius degrees is the average temperature during the 20hours per day of operation time. Besides, capacity of several reinforced concrete columns and beams, and steel members of the roof is minor that their demands respectively according to Peru and international codes. The performance of the full structure of the melt shop including concrete and steel structures presents allowed drifts according seismic provisions, however this structure behaves on its nonlinear range under demands of Peru seismic code.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-14
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
TECNIA Special Issue on Earthquake Engineering
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722
10.21754/tecnia.v29i2.722
url http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722
identifier_str_mv 10.21754/tecnia.v29i2.722
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722/1118
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722/1137
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
audio/mpeg
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake Engineering
TECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica
2309-0413
0375-7765
reponame:Revista UNI - Tecnia
instname:Universidad Nacional de Ingeniería
instacron:UNI
reponame_str Revista UNI - Tecnia
collection Revista UNI - Tecnia
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701108800479559680
spelling Seismic structural assessment of a 40 years old melt shop facilityHuaco Cardenas, Guillermo DavidInga, WaldoCamacho, AudryMelt shopPerformance base designBridge craneAssessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoid possible economical losses if this facility stops its operations after any main seismic event. It is presented the structural assessment of the infrastructure of a melt shop facility, which it used for production of structural steel shapes. This infrastructure was built at the beginning of 80’s and it is located at near Pisco city in Peru. Reinforced concrete C columns and L beams make the frames of the structure and the rood is made by steel trusts. NDT and destructive tests were made for the reinforced concrete members as well of extraction of steel coupons from the roof trusts. Auscultation of foundation, reinforced concrete and steel structures were performed. It was found that several columns present damages such as spalling of cover, impact hits from heavy vehicles, which get in the interior of the facility. The roof presents metallic dust which was accumulated by the smelter operation. Heat of 50 Celsius degrees is the average temperature during the 20hours per day of operation time. Besides, capacity of several reinforced concrete columns and beams, and steel members of the roof is minor that their demands respectively according to Peru and international codes. The performance of the full structure of the melt shop including concrete and steel structures presents allowed drifts according seismic provisions, however this structure behaves on its nonlinear range under demands of Peru seismic code.Assessment of old factory infrastructure is required in order to keep them working especially after natural hazard event such as earthquake, tornados, or variation of gravity loads. This type of structure is considered essential since it should be safety for workers during operation time and to avoid possible economical losses if this facility stops its operations after any main seismic event. It is presented the structural assessment of the infrastructure of a melt shop facility, which it used for production of structural steel shapes. This infrastructure was built at the beginning of 80’s and it is located at near Pisco city in Peru. Reinforced concrete C columns and L beams make the frames of the structure and the rood is made by steel trusts. NDT and destructive tests were made for the reinforced concrete members as well of extraction of steel coupons from the roof trusts. Auscultation of foundation, reinforced concrete and steel structures were performed. It was found that several columns present damages such as spalling of cover, impact hits from heavy vehicles, which get in the interior of the facility. The roof presents metallic dust which was accumulated by the smelter operation. Heat of 50 Celsius degrees is the average temperature during the 20hours per day of operation time. Besides, capacity of several reinforced concrete columns and beams, and steel members of the roof is minor that their demands respectively according to Peru and international codes. The performance of the full structure of the melt shop including concrete and steel structures presents allowed drifts according seismic provisions, however this structure behaves on its nonlinear range under demands of Peru seismic code.Universidad Nacional de Ingeniería2019-08-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTECNIA Special Issue on Earthquake Engineeringapplication/pdfaudio/mpeghttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/72210.21754/tecnia.v29i2.722TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake EngineeringTECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica2309-04130375-7765reponame:Revista UNI - Tecniainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722/1118http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/722/1137info:eu-repo/semantics/openAccess2021-05-29T15:55:42Zmail@mail.com -
score 13.924177
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).