Mostrando 1 - 5 Resultados de 5 Para Buscar 'Maldonado Farfán, Amanda Rosa', tiempo de consulta: 0.21s Limitar resultados
1
artículo
This study evaluated the application of the Fenton process for the removal of non-biodegradable organic matter, measured as chemical oxygen demand (COD), in the effluent of the San Jerónimo WWTP, Cusco. A Box-Behnken factorial design was used to optimize the concentrations of Fe²⁺, H₂O₂, and pH. The initial characterization of the effluent showed a pH of 7.8, COD of 180 mg/L, BOD of 75 mg/L, oils and greases of 5 mg/L, total suspended solids of 150 mg/L, and a temperature of 20°C. A total of 15 experiments were conducted with two replicates, resulting in 45 tests. The results indicated a high COD removal efficiency, reaching a maximum of 89.0% in experiment No. 9 with 60 mg/L of Fe²⁺, 600 mg/L of H₂O₂, and a pH of 3.0, confirming the feasibility of the Fenton process as an effective alternative for improving wastewater treatment in conventional plants.
2
artículo
El objetivo de la investigación fue determinar el grado de reducción de amoxicilina en aguas contaminadas, mediante el proceso de electrocoagulación. La celda de electrocoagulación trabajó con electrodos de acero inoxidable y aluminio (cátodo y ánodo respectivamente), para una capacidad de 1 litro de agua contaminada.El proceso consistió en suministrar corriente eléctrica a través de los electrodos, haciendo que las partículas en suspensión pierdan su estabilidad y así formen aglomerados que flotaron hacia la superficie del agua, así como precipitados que cayeron hacia la base de la celda de electrocoagulación. Por tal motivo, la investigación es de tipo aplicativo con un enfoque cuantitativo y diseño experimental. Para lo cual se realizaron 9 experimentos donde se trabajaron con las variables de Voltaje (7, 9 y 11V) y pH (5, 6.5 y 8), lográndose remociones entre 47.2 m...
3
artículo
The objective of this research was to determine the degree of degradation of Amoxicillin in polluted waters through the oxidation process with chlorine dioxide (ClO2). For this process, the pH (5, 6.5 and 8) and thedose of ClO2 (5, 12.5 and 20 ml) variables were studied in 47.20 ppm samples of amoxicillin in 500 mL volumes, this process was carried out in a jars-test. The results indicate that the two variables (pH and ClO2 dose) have an important effect and are significant on the percentage of eliminated Chemical Oxygen Demand (%DQOe). The mathematical model that relates the variables under study was established with a goodness of fit equal to R2 = 99.68%. Likewise, a removal of 77.3% was achieved at pH8 and a ClO2 dose of 20 mL.
4
artículo
El objetivo de la investigación fue determinar el grado de reducción de amoxicilina en aguas contaminadas, mediante el proceso de electrocoagulación. La celda de electrocoagulación trabajó con electrodos de acero inoxidable y aluminio (cátodo y ánodo respectivamente), para una capacidad de 1 litro de agua contaminada.El proceso consistió en suministrar corriente eléctrica a través de los electrodos, haciendo que las partículas en suspensión pierdan su estabilidad y así formen aglomerados que flotaron hacia la superficie del agua, así como precipitados que cayeron hacia la base de la celda de electrocoagulación. Por tal motivo, la investigación es de tipo aplicativo con un enfoque cuantitativo y diseño experimental. Para lo cual se realizaron 9 experimentos donde se trabajaron con las variables de Voltaje (7, 9 y 11V) y pH (5, 6.5 y 8), lográndose remociones entre 47.2 m...
5
artículo
The objective of this research was to determine the degree of degradation of Amoxicillin in polluted waters through the oxidation process with chlorine dioxide (ClO2). For this process, the pH (5, 6.5 and 8) and thedose of ClO2 (5, 12.5 and 20 ml) variables were studied in 47.20 ppm samples of amoxicillin in 500 mL volumes, this process was carried out in a jars-test. The results indicate that the two variables (pH and ClO2 dose) have an important effect and are significant on the percentage of eliminated Chemical Oxygen Demand (%DQOe). The mathematical model that relates the variables under study was established with a goodness of fit equal to R2 = 99.68%. Likewise, a removal of 77.3% was achieved at pH8 and a ClO2 dose of 20 mL.