Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh
Descripción del Articulo
The seismic silence of the Peruvian coast shows the need to evaluate essential old structures such as schools and hospitals on this area. This type of infrastructure should keep being operational despite a large earthquake. Therefore, it is necessary to reinforce them since they do not meet current...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2023 |
Institución: | Universidad Peruana de Ciencias Aplicadas |
Repositorio: | UPC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorioacademico.upc.edu.pe:10757/673023 |
Enlace del recurso: | http://hdl.handle.net/10757/673023 |
Nivel de acceso: | acceso embargado |
Materia: | Hospital nonlinear pushover URM masonry welded mesh |
id |
UUPC_e45fa691eb259fa0dd02a3b7bda14bf9 |
---|---|
oai_identifier_str |
oai:repositorioacademico.upc.edu.pe:10757/673023 |
network_acronym_str |
UUPC |
network_name_str |
UPC-Institucional |
repository_id_str |
2670 |
dc.title.es_PE.fl_str_mv |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
title |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
spellingShingle |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh Balvin, Yuri Huaringa Hospital nonlinear pushover URM masonry welded mesh |
title_short |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
title_full |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
title_fullStr |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
title_full_unstemmed |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
title_sort |
Nonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded mesh |
author |
Balvin, Yuri Huaringa |
author_facet |
Balvin, Yuri Huaringa Canales, Romina Tamara Saire Cardenas, Guillermo Huaco |
author_role |
author |
author2 |
Canales, Romina Tamara Saire Cardenas, Guillermo Huaco |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Balvin, Yuri Huaringa Canales, Romina Tamara Saire Cardenas, Guillermo Huaco |
dc.subject.es_PE.fl_str_mv |
Hospital nonlinear pushover URM masonry welded mesh |
topic |
Hospital nonlinear pushover URM masonry welded mesh |
description |
The seismic silence of the Peruvian coast shows the need to evaluate essential old structures such as schools and hospitals on this area. This type of infrastructure should keep being operational despite a large earthquake. Therefore, it is necessary to reinforce them since they do not meet current seismic design codes. It is shown the performance of a retrofitted masonry hospital made by two different types of brick, clay and adobe or rammed earth material. The retrofitted process consisted of strengthening the slender clay artisanal masonry walls with electro welded mesh, keeping the robust and thick adobe walls with no reinforcement. Due the structural assessment it was found that adobe walls were stiff enough to carry out lateral loads and short lateral displacement, however the clay masonry walls need to be strengthened specially by shear actions. The results of this research show that the retrofitted infrastructure is partially effective as it improves the shear capacity (30% on the longitudinal X axis and 16% on the transverse Y axis) and displacement of the structure; however, early shear hinges are still evident, which shows that the structure continues to maintain a fragile behavior On the other hand, the percentage of improvement differs in both axes since more walls were reinforced in the X axis than in the Y axis. As well it was reached a lateral stiffness improving for both directions of the hospital. |
publishDate |
2023 |
dc.date.accessioned.none.fl_str_mv |
2024-03-12T15:03:19Z |
dc.date.available.none.fl_str_mv |
2024-03-12T15:03:19Z |
dc.date.issued.fl_str_mv |
2023-01-01 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
dc.identifier.doi.none.fl_str_mv |
10.1109/CONIITI61170.2023.10324044 |
dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/10757/673023 |
dc.identifier.journal.es_PE.fl_str_mv |
2023 9th International Conference on Innovation and Trends in Engineering, CONIITI 2023 - Proceedings |
dc.identifier.eid.none.fl_str_mv |
2-s2.0-85179556634 |
dc.identifier.scopusid.none.fl_str_mv |
SCOPUS_ID:85179556634 |
dc.identifier.isni.none.fl_str_mv |
0000 0001 2196 144X |
identifier_str_mv |
10.1109/CONIITI61170.2023.10324044 2023 9th International Conference on Innovation and Trends in Engineering, CONIITI 2023 - Proceedings 2-s2.0-85179556634 SCOPUS_ID:85179556634 0000 0001 2196 144X |
url |
http://hdl.handle.net/10757/673023 |
dc.language.iso.es_PE.fl_str_mv |
eng |
language |
eng |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/embargoedAccess |
eu_rights_str_mv |
embargoedAccess |
dc.format.es_PE.fl_str_mv |
application/html |
dc.publisher.es_PE.fl_str_mv |
Institute of Electrical and Electronics Engineers Inc. |
dc.source.none.fl_str_mv |
reponame:UPC-Institucional instname:Universidad Peruana de Ciencias Aplicadas instacron:UPC |
instname_str |
Universidad Peruana de Ciencias Aplicadas |
instacron_str |
UPC |
institution |
UPC |
reponame_str |
UPC-Institucional |
collection |
UPC-Institucional |
dc.source.journaltitle.none.fl_str_mv |
2023 9th International Conference on Innovation and Trends in Engineering, CONIITI 2023 - Proceedings |
bitstream.url.fl_str_mv |
https://repositorioacademico.upc.edu.pe/bitstream/10757/673023/1/license.txt |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 |
repository.name.fl_str_mv |
Repositorio académico upc |
repository.mail.fl_str_mv |
upc@openrepository.com |
_version_ |
1846066002292375552 |
spelling |
531525bdd67e953b472aac54943a10e5300ae09e4c9193dbae3b5c6bcbaaf6fab9c300cb20aa4f056d9b9a33dc05139e5de03dBalvin, Yuri HuaringaCanales, Romina Tamara SaireCardenas, Guillermo Huaco2024-03-12T15:03:19Z2024-03-12T15:03:19Z2023-01-0110.1109/CONIITI61170.2023.10324044http://hdl.handle.net/10757/6730232023 9th International Conference on Innovation and Trends in Engineering, CONIITI 2023 - Proceedings2-s2.0-85179556634SCOPUS_ID:851795566340000 0001 2196 144XThe seismic silence of the Peruvian coast shows the need to evaluate essential old structures such as schools and hospitals on this area. This type of infrastructure should keep being operational despite a large earthquake. Therefore, it is necessary to reinforce them since they do not meet current seismic design codes. It is shown the performance of a retrofitted masonry hospital made by two different types of brick, clay and adobe or rammed earth material. The retrofitted process consisted of strengthening the slender clay artisanal masonry walls with electro welded mesh, keeping the robust and thick adobe walls with no reinforcement. Due the structural assessment it was found that adobe walls were stiff enough to carry out lateral loads and short lateral displacement, however the clay masonry walls need to be strengthened specially by shear actions. The results of this research show that the retrofitted infrastructure is partially effective as it improves the shear capacity (30% on the longitudinal X axis and 16% on the transverse Y axis) and displacement of the structure; however, early shear hinges are still evident, which shows that the structure continues to maintain a fragile behavior On the other hand, the percentage of improvement differs in both axes since more walls were reinforced in the X axis than in the Y axis. As well it was reached a lateral stiffness improving for both directions of the hospital.ODS 3: Salud y BienestarODS 9: Industria, Innovación e InfraestructuraODS 11: Ciudades y Comunidades Sosteniblesapplication/htmlengInstitute of Electrical and Electronics Engineers Inc.info:eu-repo/semantics/embargoedAccessHospitalnonlinearpushoverURM masonrywelded meshNonlinear seismic behavior of a masonry hospital over 80 years old reinforced with electro welded meshinfo:eu-repo/semantics/article2023 9th International Conference on Innovation and Trends in Engineering, CONIITI 2023 - Proceedingsreponame:UPC-Institucionalinstname:Universidad Peruana de Ciencias Aplicadasinstacron:UPCLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorioacademico.upc.edu.pe/bitstream/10757/673023/1/license.txt8a4605be74aa9ea9d79846c1fba20a33MD51false10757/673023oai:repositorioacademico.upc.edu.pe:10757/6730232024-07-20 04:20:44.923Repositorio académico upcupc@openrepository.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 |
score |
13.882472 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).