Methodology for the multichannel recording of upper limb muscle activity
Descripción del Articulo
In the study of the functioning of the muscle, the study standard is to be able to analyze its behavior or functioning, this behavior is represented by a continuous signal where the muscle signal can be recorded and visualized, to perform this registration a designed circuit is required. For the cap...
Autores: | , , , , , , , , |
---|---|
Formato: | objeto de conferencia |
Fecha de Publicación: | 2022 |
Institución: | Universidad Tecnológica del Perú |
Repositorio: | UTP-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.utp.edu.pe:20.500.12867/6174 |
Enlace del recurso: | https://hdl.handle.net/20.500.12867/6174 https://doi.org/10.1088/1742-6596/2318/1/012031 |
Nivel de acceso: | acceso abierto |
Materia: | Physiology Muscles Electromyography https://purl.org/pe-repo/ocde/ford#2.02.01 https://purl.org/pe-repo/ocde/ford#3.00.00 |
id |
UTPD_f8144ed287f40aba3c58500cce8c7143 |
---|---|
oai_identifier_str |
oai:repositorio.utp.edu.pe:20.500.12867/6174 |
network_acronym_str |
UTPD |
network_name_str |
UTP-Institucional |
repository_id_str |
4782 |
dc.title.es_PE.fl_str_mv |
Methodology for the multichannel recording of upper limb muscle activity |
title |
Methodology for the multichannel recording of upper limb muscle activity |
spellingShingle |
Methodology for the multichannel recording of upper limb muscle activity Ovalle Paulino, Denis Christian Physiology Muscles Electromyography https://purl.org/pe-repo/ocde/ford#2.02.01 https://purl.org/pe-repo/ocde/ford#3.00.00 |
title_short |
Methodology for the multichannel recording of upper limb muscle activity |
title_full |
Methodology for the multichannel recording of upper limb muscle activity |
title_fullStr |
Methodology for the multichannel recording of upper limb muscle activity |
title_full_unstemmed |
Methodology for the multichannel recording of upper limb muscle activity |
title_sort |
Methodology for the multichannel recording of upper limb muscle activity |
author |
Ovalle Paulino, Denis Christian |
author_facet |
Ovalle Paulino, Denis Christian Cordova-Buiza, Franklin Herrera, Lucas Auccahuas, Aly Romero Echevarría, Martha Rojas, Karin Barrera Loza, Ana Figueroa Revilla, Jorge Herrera Salazar, José Luis |
author_role |
author |
author2 |
Cordova-Buiza, Franklin Herrera, Lucas Auccahuas, Aly Romero Echevarría, Martha Rojas, Karin Barrera Loza, Ana Figueroa Revilla, Jorge Herrera Salazar, José Luis |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Ovalle Paulino, Denis Christian Cordova-Buiza, Franklin Herrera, Lucas Auccahuas, Aly Romero Echevarría, Martha Rojas, Karin Barrera Loza, Ana Figueroa Revilla, Jorge Herrera Salazar, José Luis |
dc.subject.es_PE.fl_str_mv |
Physiology Muscles Electromyography |
topic |
Physiology Muscles Electromyography https://purl.org/pe-repo/ocde/ford#2.02.01 https://purl.org/pe-repo/ocde/ford#3.00.00 |
dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.02.01 https://purl.org/pe-repo/ocde/ford#3.00.00 |
description |
In the study of the functioning of the muscle, the study standard is to be able to analyze its behavior or functioning, this behavior is represented by a continuous signal where the muscle signal can be recorded and visualized, to perform this registration a designed circuit is required. For the capture of electromyography signals, there are many options of these circuits in the market, depending on the application, the part of the body that is required to be analyzed, the best option can be chosen, in this work, we present a methodology for recording in Simultaneous 8 signals, for the characteristic use of the arm muscles, due to its special shape, which allows it to be placed in the form of a bracelet, the signals that are acquired simultaneously and individually, can be used in many applications depending on the problem and challenge, recommending for use on the arm and providing a clean signal allowing Being used in the design of detection mechanisms for some pathologies related to the arm muscles and in the design of control mechanisms for the design of prostheses. |
publishDate |
2022 |
dc.date.accessioned.none.fl_str_mv |
2022-11-07T20:40:42Z |
dc.date.available.none.fl_str_mv |
2022-11-07T20:40:42Z |
dc.date.issued.fl_str_mv |
2022 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
dc.type.version.es_PE.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.issn.none.fl_str_mv |
1742-6596 |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12867/6174 |
dc.identifier.journal.es_PE.fl_str_mv |
Journal of Physics: Conference Series |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1088/1742-6596/2318/1/012031 |
identifier_str_mv |
1742-6596 Journal of Physics: Conference Series |
url |
https://hdl.handle.net/20.500.12867/6174 https://doi.org/10.1088/1742-6596/2318/1/012031 |
dc.language.iso.es_PE.fl_str_mv |
eng |
language |
eng |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
dc.format.es_PE.fl_str_mv |
application/pdf |
dc.publisher.es_PE.fl_str_mv |
IOP Publishing |
dc.publisher.country.es_PE.fl_str_mv |
GB |
dc.source.es_PE.fl_str_mv |
Repositorio Institucional - UTP Universidad Tecnológica del Perú |
dc.source.none.fl_str_mv |
reponame:UTP-Institucional instname:Universidad Tecnológica del Perú instacron:UTP |
instname_str |
Universidad Tecnológica del Perú |
instacron_str |
UTP |
institution |
UTP |
reponame_str |
UTP-Institucional |
collection |
UTP-Institucional |
bitstream.url.fl_str_mv |
http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/1/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/2/license.txt http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/3/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.txt http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/4/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.jpg |
bitstream.checksum.fl_str_mv |
190809620eb2b442eaf1657d875ba7d1 8a4605be74aa9ea9d79846c1fba20a33 e9bcddc037d8e9a07627aadfe8d98f64 b33c240cca5afd8c277a3dd644c5c0b7 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional de la Universidad Tecnológica del Perú |
repository.mail.fl_str_mv |
repositorio@utp.edu.pe |
_version_ |
1817984839678164992 |
spelling |
Ovalle Paulino, Denis ChristianCordova-Buiza, FranklinHerrera, LucasAuccahuas, AlyRomero Echevarría, MarthaRojas, KarinBarrera Loza, AnaFigueroa Revilla, JorgeHerrera Salazar, José Luis2022-11-07T20:40:42Z2022-11-07T20:40:42Z20221742-6596https://hdl.handle.net/20.500.12867/6174Journal of Physics: Conference Serieshttps://doi.org/10.1088/1742-6596/2318/1/012031In the study of the functioning of the muscle, the study standard is to be able to analyze its behavior or functioning, this behavior is represented by a continuous signal where the muscle signal can be recorded and visualized, to perform this registration a designed circuit is required. For the capture of electromyography signals, there are many options of these circuits in the market, depending on the application, the part of the body that is required to be analyzed, the best option can be chosen, in this work, we present a methodology for recording in Simultaneous 8 signals, for the characteristic use of the arm muscles, due to its special shape, which allows it to be placed in the form of a bracelet, the signals that are acquired simultaneously and individually, can be used in many applications depending on the problem and challenge, recommending for use on the arm and providing a clean signal allowing Being used in the design of detection mechanisms for some pathologies related to the arm muscles and in the design of control mechanisms for the design of prostheses.Campus Lima Centroapplication/pdfengIOP PublishingGBinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/Repositorio Institucional - UTPUniversidad Tecnológica del Perúreponame:UTP-Institucionalinstname:Universidad Tecnológica del Perúinstacron:UTPPhysiologyMusclesElectromyographyhttps://purl.org/pe-repo/ocde/ford#2.02.01https://purl.org/pe-repo/ocde/ford#3.00.00Methodology for the multichannel recording of upper limb muscle activityinfo:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionORIGINALD.Ovalle_JPCS_Conference_Paper_eng_2022.pdfD.Ovalle_JPCS_Conference_Paper_eng_2022.pdfapplication/pdf622940http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/1/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf190809620eb2b442eaf1657d875ba7d1MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTD.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.txtD.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.txtExtracted texttext/plain14136http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/3/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.txte9bcddc037d8e9a07627aadfe8d98f64MD53THUMBNAILD.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.jpgD.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.jpgGenerated Thumbnailimage/jpeg18396http://repositorio.utp.edu.pe/bitstream/20.500.12867/6174/4/D.Ovalle_JPCS_Conference_Paper_eng_2022.pdf.jpgb33c240cca5afd8c277a3dd644c5c0b7MD5420.500.12867/6174oai:repositorio.utp.edu.pe:20.500.12867/61742022-11-07 17:02:49.805Repositorio Institucional de la Universidad Tecnológica del Perúrepositorio@utp.edu.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 |
score |
13.836569 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).