Structural integrity assessment in the construction of the Comuneros II Bridge: PIT test case study (ASTM D5882) on abutments
Descripción del Articulo
This article presents the results of the pile integrity tests (PIT) according to the ASTM D5882 standard, carried out in the construction project of the Comuneros II Bridge in Huancayo, Peru. The main objective of these tests was to evaluate the structural integrity of the piles used in the bridge,...
| Autores: | , , , |
|---|---|
| Formato: | objeto de conferencia |
| Fecha de Publicación: | 2024 |
| Institución: | Universidad Tecnológica del Perú |
| Repositorio: | UTP-Institucional |
| Lenguaje: | español |
| OAI Identifier: | oai:repositorio.utp.edu.pe:20.500.12867/14484 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12867/14484 https://doi.org/10.1051/e3sconf/202456302008 |
| Nivel de acceso: | acceso abierto |
| Materia: | Structural integrity Bridge Pile integrity https://purl.org/pe-repo/ocde/ford#2.11.04 |
| Sumario: | This article presents the results of the pile integrity tests (PIT) according to the ASTM D5882 standard, carried out in the construction project of the Comuneros II Bridge in Huancayo, Peru. The main objective of these tests was to evaluate the structural integrity of the piles used in the bridge, identifying possible failures or damage along its shaft. Testing was conducted using a model FV "PIT Collector" manufactured by Pile Dynamics, Inc., and spanned multiple project locations, allowing for a comprehensive assessment of pile quality. The field services were carried out on July 26, 2022, and the detailed analyses were subsequently carried out in the office. The results obtained were analyzed to verify the consistency and reliability of the piles, providing a detailed view of their structural condition. In addition, the calibration certificates of the sensors used are presented, ensuring the accuracy and validity of the data collected. This study not only contributes to ensuring the safety and durability of the Comuneros II Bridge, but also provides a valuable reference for future structural integrity assessments on similar construction projects. |
|---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).