MIMO fractional order control of a water tank plant
Descripción del Articulo
This work implements a MIMO (Multiple Input Multiple Output) FO (Fractional Order) control system for controlling the level and temperature of the water inside a tank by means of two inflow rates: cold and hot water, which are mixed to produce an outflow rate. Such a process exhibits coupling betwee...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2019 |
| Institución: | Universidad de Ingeniería y tecnología |
| Repositorio: | UTEC-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.utec.edu.pe:20.500.12815/200 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12815/200 http://dx.doi.org/10.25046/aj040641 |
| Nivel de acceso: | acceso abierto |
| Materia: | Fractional order controller Integer order controller Water tank plant Centralized control |
| id |
UTEC_aebfd71fd11253a8335bf3b429242220 |
|---|---|
| oai_identifier_str |
oai:repositorio.utec.edu.pe:20.500.12815/200 |
| network_acronym_str |
UTEC |
| network_name_str |
UTEC-Institucional |
| repository_id_str |
4822 |
| spelling |
Rojas–Moreno, ArturoHernandez–Garagatti, Juan2021-03-16T23:23:01Z2021-03-16T23:23:01Z2019-12-232415-6698https://hdl.handle.net/20.500.12815/200http://dx.doi.org/10.25046/aj040641Advances in Science, Technology and Engineering SystemsThis work implements a MIMO (Multiple Input Multiple Output) FO (Fractional Order) control system for controlling the level and temperature of the water inside a tank by means of two inflow rates: cold and hot water, which are mixed to produce an outflow rate. Such a process exhibits coupling between inputs and outputs. A linear model of the plant is obtained experimentally. Such a model, the transfer matrix function of the plant, is used to design a centralized MIMO IO (Integer Order) controller that permits to achieve complete decoupling between the set points of level and temperature and the corresponding controlled outputs: level and temperature in the tank. The MIMO FO controller is obtained making fractional all de transfer functions of the MIMO IO controller. Experimental results demonstrate that the MIMO FO control system improves the control performance of the plant outputs: level and temperature of the water in the tank.application/pdfengASTES Publishersinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Repositorio Institucional UTECUniversidad de Ingeniería y Tecnología - UTECreponame:UTEC-Institucionalinstname:Universidad de Ingeniería y tecnologíainstacron:UTECFractional order controllerInteger order controllerWater tank plantCentralized controlMIMO fractional order control of a water tank plantinfo:eu-repo/semantics/articleORIGINAL10.25046aj040641.pdf10.25046aj040641.pdfapplication/pdf7740828http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/1/10.25046aj040641.pdf6f002798fa887aa318b7180983a1e298MD51open accessTEXT10.25046aj040641.pdf.txt10.25046aj040641.pdf.txtExtracted texttext/plain24067http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/6/10.25046aj040641.pdf.txt956ec9e430091ff9b73c24e4279ce1d9MD56open accessTHUMBNAIL10.25046aj040641.pdf.jpg10.25046aj040641.pdf.jpgGenerated Thumbnailimage/jpeg13462http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/7/10.25046aj040641.pdf.jpgb84602f6a8fb49091809601d99d71895MD57open access20.500.12815/200oai:repositorio.utec.edu.pe:20.500.12815/2002024-04-10 15:56:32.539open accessRepositorio Institucional UTECrepositorio@utec.edu.pe |
| dc.title.es_PE.fl_str_mv |
MIMO fractional order control of a water tank plant |
| title |
MIMO fractional order control of a water tank plant |
| spellingShingle |
MIMO fractional order control of a water tank plant Rojas–Moreno, Arturo Fractional order controller Integer order controller Water tank plant Centralized control |
| title_short |
MIMO fractional order control of a water tank plant |
| title_full |
MIMO fractional order control of a water tank plant |
| title_fullStr |
MIMO fractional order control of a water tank plant |
| title_full_unstemmed |
MIMO fractional order control of a water tank plant |
| title_sort |
MIMO fractional order control of a water tank plant |
| author |
Rojas–Moreno, Arturo |
| author_facet |
Rojas–Moreno, Arturo Hernandez–Garagatti, Juan |
| author_role |
author |
| author2 |
Hernandez–Garagatti, Juan |
| author2_role |
author |
| dc.contributor.author.fl_str_mv |
Rojas–Moreno, Arturo Hernandez–Garagatti, Juan |
| dc.subject.es_PE.fl_str_mv |
Fractional order controller Integer order controller Water tank plant Centralized control |
| topic |
Fractional order controller Integer order controller Water tank plant Centralized control |
| description |
This work implements a MIMO (Multiple Input Multiple Output) FO (Fractional Order) control system for controlling the level and temperature of the water inside a tank by means of two inflow rates: cold and hot water, which are mixed to produce an outflow rate. Such a process exhibits coupling between inputs and outputs. A linear model of the plant is obtained experimentally. Such a model, the transfer matrix function of the plant, is used to design a centralized MIMO IO (Integer Order) controller that permits to achieve complete decoupling between the set points of level and temperature and the corresponding controlled outputs: level and temperature in the tank. The MIMO FO controller is obtained making fractional all de transfer functions of the MIMO IO controller. Experimental results demonstrate that the MIMO FO control system improves the control performance of the plant outputs: level and temperature of the water in the tank. |
| publishDate |
2019 |
| dc.date.accessioned.none.fl_str_mv |
2021-03-16T23:23:01Z |
| dc.date.available.none.fl_str_mv |
2021-03-16T23:23:01Z |
| dc.date.issued.fl_str_mv |
2019-12-23 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.issn.es_PE.fl_str_mv |
2415-6698 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12815/200 |
| dc.identifier.doi.es_PE.fl_str_mv |
http://dx.doi.org/10.25046/aj040641 |
| dc.identifier.journal.es_PE.fl_str_mv |
Advances in Science, Technology and Engineering Systems |
| identifier_str_mv |
2415-6698 Advances in Science, Technology and Engineering Systems |
| url |
https://hdl.handle.net/20.500.12815/200 http://dx.doi.org/10.25046/aj040641 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.format.es_PE.fl_str_mv |
application/pdf |
| dc.publisher.es_PE.fl_str_mv |
ASTES Publishers |
| dc.source.es_PE.fl_str_mv |
Repositorio Institucional UTEC Universidad de Ingeniería y Tecnología - UTEC |
| dc.source.none.fl_str_mv |
reponame:UTEC-Institucional instname:Universidad de Ingeniería y tecnología instacron:UTEC |
| instname_str |
Universidad de Ingeniería y tecnología |
| instacron_str |
UTEC |
| institution |
UTEC |
| reponame_str |
UTEC-Institucional |
| collection |
UTEC-Institucional |
| bitstream.url.fl_str_mv |
http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/1/10.25046aj040641.pdf http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/6/10.25046aj040641.pdf.txt http://repositorio.utec.edu.pe/bitstream/20.500.12815/200/7/10.25046aj040641.pdf.jpg |
| bitstream.checksum.fl_str_mv |
6f002798fa887aa318b7180983a1e298 956ec9e430091ff9b73c24e4279ce1d9 b84602f6a8fb49091809601d99d71895 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Institucional UTEC |
| repository.mail.fl_str_mv |
repositorio@utec.edu.pe |
| _version_ |
1843166367820283904 |
| score |
13.936249 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).