A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements
Descripción del Articulo
Objectives: To assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. Materials and methods: Forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomograph...
| Autores: | , , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2018 |
| Institución: | Universidad de San Martín de Porres |
| Repositorio: | USMP-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.usmp.edu.pe:20.500.12727/6268 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12727/6268 https://doi.org/10.17126/joralres.2018.076 |
| Nivel de acceso: | acceso abierto |
| Materia: | Tomografía computarizada de haz cónico Cefalometría Reproducibilidad de los resultados https://purl.org/pe-repo/ocde/ford#3.02.00 |
| id |
USMP_6be8025c9f1d25421fde7144a5d2fbeb |
|---|---|
| oai_identifier_str |
oai:repositorio.usmp.edu.pe:20.500.12727/6268 |
| network_acronym_str |
USMP |
| network_name_str |
USMP-Institucional |
| repository_id_str |
2089 |
| dc.title.es_PE.fl_str_mv |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| title |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| spellingShingle |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements Calle-Morocho, Jesica Tomografía computarizada de haz cónico Cefalometría Reproducibilidad de los resultados https://purl.org/pe-repo/ocde/ford#3.02.00 |
| title_short |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| title_full |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| title_fullStr |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| title_full_unstemmed |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| title_sort |
A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements |
| author |
Calle-Morocho, Jesica |
| author_facet |
Calle-Morocho, Jesica Morales-Vadillo, Rafael Guevara-Canale, Janet Alva-Cuneo, Carlos |
| author_role |
author |
| author2 |
Morales-Vadillo, Rafael Guevara-Canale, Janet Alva-Cuneo, Carlos |
| author2_role |
author author author |
| dc.contributor.author.fl_str_mv |
Calle-Morocho, Jesica Morales-Vadillo, Rafael Guevara-Canale, Janet Alva-Cuneo, Carlos |
| dc.subject.es_PE.fl_str_mv |
Tomografía computarizada de haz cónico Cefalometría Reproducibilidad de los resultados |
| topic |
Tomografía computarizada de haz cónico Cefalometría Reproducibilidad de los resultados https://purl.org/pe-repo/ocde/ford#3.02.00 |
| dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#3.02.00 |
| description |
Objectives: To assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. Materials and methods: Forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomography were analyzed, corresponding to forty patients from the nstituto de Diagnóstico Maxilofacial in Lima, Peru. The principal investigator, who had been previously calibrated, made two measurements within a timespan of fifteen days using the analysis of Steiner and the NemoCeph software, and the difference between the obtained measurements was evaluated to determine if it was significant. Results: For digital lateral radiographs the difference varied between 0.00º - 0.45º and 0.01mm - 0.16mm, with statistical significance for distance between Pg and NB for lateral virtual cephalograms between 0.03º - 0.73º and 0.01mm - 0.43mm, with statistical significance for SE distance. The comparison between the two types of image in the first measurement showed a difference of 0.08º - 1.15º and 0.00mm - 1.43mm with statistical significance for four angular measurements and one linear. The comparison between the two types of image in the second measurement showed a difference of 0.13º - 1º and 0.02mm - 1.32mm with a statistically significant difference for three angular and two linear measurements. Conclusions: The difference between the two types of image is minimal; Both evaluated methods can be used effectively. |
| publishDate |
2018 |
| dc.date.accessioned.none.fl_str_mv |
2020-06-26T22:59:21Z |
| dc.date.available.none.fl_str_mv |
2020-06-26T22:59:21Z |
| dc.date.issued.fl_str_mv |
2018-11-30 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.citation.es_PE.fl_str_mv |
Calle J., Morales R., Guevara J., Alva C. A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements.. Journal of Oral Research. 2018; 7(8): 308-317. |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12727/6268 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.17126/joralres.2018.076 |
| identifier_str_mv |
Calle J., Morales R., Guevara J., Alva C. A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements.. Journal of Oral Research. 2018; 7(8): 308-317. |
| url |
https://hdl.handle.net/20.500.12727/6268 https://doi.org/10.17126/joralres.2018.076 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
urn:issn:1575-1813 |
| dc.relation.ispartofseries.none.fl_str_mv |
Journal of Oral Research;vol. 7, no. 8 |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.es_PE.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.format.extent.es_PE.fl_str_mv |
pp. 308-317 |
| dc.publisher.es_PE.fl_str_mv |
Facultad de Odontología, Universidad de Concepción, Chile. |
| dc.publisher.country.es_PE.fl_str_mv |
CL |
| dc.source.es_PE.fl_str_mv |
Repositorio Académico USMP Universidad de San Martín de Porres - USMP |
| dc.source.none.fl_str_mv |
reponame:USMP-Institucional instname:Universidad de San Martín de Porres instacron:USMP |
| instname_str |
Universidad de San Martín de Porres |
| instacron_str |
USMP |
| institution |
USMP |
| reponame_str |
USMP-Institucional |
| collection |
USMP-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/1/calle_mjfmh-2018.pdf https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/2/license.txt https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/3/calle_mjfmh-2018.pdf.txt https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/4/calle_mjfmh-2018.pdf.jpg |
| bitstream.checksum.fl_str_mv |
0297886346e52a59a04ff726b89bedb0 8a4605be74aa9ea9d79846c1fba20a33 f0296da85f2ff0ebe600fe4ef4819154 bf26d4677e8aa33256c61483c60c6342 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
| repository.name.fl_str_mv |
REPOSITORIO ACADEMICO USMP |
| repository.mail.fl_str_mv |
repositorio@usmp.pe |
| _version_ |
1850062159491366912 |
| spelling |
Calle-Morocho, JesicaMorales-Vadillo, RafaelGuevara-Canale, JanetAlva-Cuneo, Carlos2020-06-26T22:59:21Z2020-06-26T22:59:21Z2018-11-30Calle J., Morales R., Guevara J., Alva C. A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurements.. Journal of Oral Research. 2018; 7(8): 308-317.https://hdl.handle.net/20.500.12727/6268https://doi.org/10.17126/joralres.2018.076Objectives: To assess discrepancies in cephalometric measurements from digital lateral radiography and virtual cone-beam computed assisted tomography cephalogram. Materials and methods: Forty digital lateral radiographs and forty virtual cephalograms obtained by cone-beam computed assisted tomography were analyzed, corresponding to forty patients from the nstituto de Diagnóstico Maxilofacial in Lima, Peru. The principal investigator, who had been previously calibrated, made two measurements within a timespan of fifteen days using the analysis of Steiner and the NemoCeph software, and the difference between the obtained measurements was evaluated to determine if it was significant. Results: For digital lateral radiographs the difference varied between 0.00º - 0.45º and 0.01mm - 0.16mm, with statistical significance for distance between Pg and NB for lateral virtual cephalograms between 0.03º - 0.73º and 0.01mm - 0.43mm, with statistical significance for SE distance. The comparison between the two types of image in the first measurement showed a difference of 0.08º - 1.15º and 0.00mm - 1.43mm with statistical significance for four angular measurements and one linear. The comparison between the two types of image in the second measurement showed a difference of 0.13º - 1º and 0.02mm - 1.32mm with a statistically significant difference for three angular and two linear measurements. Conclusions: The difference between the two types of image is minimal; Both evaluated methods can be used effectively.pp. 308-317engFacultad de Odontología, Universidad de Concepción, Chile.CLurn:issn:1575-1813Journal of Oral Research;vol. 7, no. 8info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/4.0/Repositorio Académico USMPUniversidad de San Martín de Porres - USMPreponame:USMP-Institucionalinstname:Universidad de San Martín de Porresinstacron:USMPTomografía computarizada de haz cónicoCefalometríaReproducibilidad de los resultadoshttps://purl.org/pe-repo/ocde/ford#3.02.00A comparative study of digital lateral radiography and virtual cone-beam computed assisted cephalogram in cephalometric measurementsinfo:eu-repo/semantics/articleMedicina HumanaUniversidad de San Martín de Porres. Facultad de Medicina HumanaMedicinaORIGINALcalle_mjfmh-2018.pdfcalle_mjfmh-2018.pdfTrabajoapplication/pdf571187https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/1/calle_mjfmh-2018.pdf0297886346e52a59a04ff726b89bedb0MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTcalle_mjfmh-2018.pdf.txtcalle_mjfmh-2018.pdf.txtExtracted texttext/plain41847https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/3/calle_mjfmh-2018.pdf.txtf0296da85f2ff0ebe600fe4ef4819154MD53THUMBNAILcalle_mjfmh-2018.pdf.jpgcalle_mjfmh-2018.pdf.jpgGenerated Thumbnailimage/jpeg8445https://repositorio.usmp.edu.pe/bitstream/20.500.12727/6268/4/calle_mjfmh-2018.pdf.jpgbf26d4677e8aa33256c61483c60c6342MD5420.500.12727/6268oai:repositorio.usmp.edu.pe:20.500.12727/62682025-08-15 09:54:46.126REPOSITORIO ACADEMICO USMPrepositorio@usmp.peTk9URTogUExBQ0UgWU9VUiBPV04gTElDRU5TRSBIRVJFClRoaXMgc2FtcGxlIGxpY2Vuc2UgaXMgcHJvdmlkZWQgZm9yIGluZm9ybWF0aW9uYWwgcHVycG9zZXMgb25seS4KCk5PTi1FWENMVVNJVkUgRElTVFJJQlVUSU9OIExJQ0VOU0UKCkJ5IHNpZ25pbmcgYW5kIHN1Ym1pdHRpbmcgdGhpcyBsaWNlbnNlLCB5b3UgKHRoZSBhdXRob3Iocykgb3IgY29weXJpZ2h0Cm93bmVyKSBncmFudHMgdG8gRFNwYWNlIFVuaXZlcnNpdHkgKERTVSkgdGhlIG5vbi1leGNsdXNpdmUgcmlnaHQgdG8gcmVwcm9kdWNlLAp0cmFuc2xhdGUgKGFzIGRlZmluZWQgYmVsb3cpLCBhbmQvb3IgZGlzdHJpYnV0ZSB5b3VyIHN1Ym1pc3Npb24gKGluY2x1ZGluZwp0aGUgYWJzdHJhY3QpIHdvcmxkd2lkZSBpbiBwcmludCBhbmQgZWxlY3Ryb25pYyBmb3JtYXQgYW5kIGluIGFueSBtZWRpdW0sCmluY2x1ZGluZyBidXQgbm90IGxpbWl0ZWQgdG8gYXVkaW8gb3IgdmlkZW8uCgpZb3UgYWdyZWUgdGhhdCBEU1UgbWF5LCB3aXRob3V0IGNoYW5naW5nIHRoZSBjb250ZW50LCB0cmFuc2xhdGUgdGhlCnN1Ym1pc3Npb24gdG8gYW55IG1lZGl1bSBvciBmb3JtYXQgZm9yIHRoZSBwdXJwb3NlIG9mIHByZXNlcnZhdGlvbi4KCllvdSBhbHNvIGFncmVlIHRoYXQgRFNVIG1heSBrZWVwIG1vcmUgdGhhbiBvbmUgY29weSBvZiB0aGlzIHN1Ym1pc3Npb24gZm9yCnB1cnBvc2VzIG9mIHNlY3VyaXR5LCBiYWNrLXVwIGFuZCBwcmVzZXJ2YXRpb24uCgpZb3UgcmVwcmVzZW50IHRoYXQgdGhlIHN1Ym1pc3Npb24gaXMgeW91ciBvcmlnaW5hbCB3b3JrLCBhbmQgdGhhdCB5b3UgaGF2ZQp0aGUgcmlnaHQgdG8gZ3JhbnQgdGhlIHJpZ2h0cyBjb250YWluZWQgaW4gdGhpcyBsaWNlbnNlLiBZb3UgYWxzbyByZXByZXNlbnQKdGhhdCB5b3VyIHN1Ym1pc3Npb24gZG9lcyBub3QsIHRvIHRoZSBiZXN0IG9mIHlvdXIga25vd2xlZGdlLCBpbmZyaW5nZSB1cG9uCmFueW9uZSdzIGNvcHlyaWdodC4KCklmIHRoZSBzdWJtaXNzaW9uIGNvbnRhaW5zIG1hdGVyaWFsIGZvciB3aGljaCB5b3UgZG8gbm90IGhvbGQgY29weXJpZ2h0LAp5b3UgcmVwcmVzZW50IHRoYXQgeW91IGhhdmUgb2J0YWluZWQgdGhlIHVucmVzdHJpY3RlZCBwZXJtaXNzaW9uIG9mIHRoZQpjb3B5cmlnaHQgb3duZXIgdG8gZ3JhbnQgRFNVIHRoZSByaWdodHMgcmVxdWlyZWQgYnkgdGhpcyBsaWNlbnNlLCBhbmQgdGhhdApzdWNoIHRoaXJkLXBhcnR5IG93bmVkIG1hdGVyaWFsIGlzIGNsZWFybHkgaWRlbnRpZmllZCBhbmQgYWNrbm93bGVkZ2VkCndpdGhpbiB0aGUgdGV4dCBvciBjb250ZW50IG9mIHRoZSBzdWJtaXNzaW9uLgoKSUYgVEhFIFNVQk1JU1NJT04gSVMgQkFTRUQgVVBPTiBXT1JLIFRIQVQgSEFTIEJFRU4gU1BPTlNPUkVEIE9SIFNVUFBPUlRFRApCWSBBTiBBR0VOQ1kgT1IgT1JHQU5JWkFUSU9OIE9USEVSIFRIQU4gRFNVLCBZT1UgUkVQUkVTRU5UIFRIQVQgWU9VIEhBVkUKRlVMRklMTEVEIEFOWSBSSUdIVCBPRiBSRVZJRVcgT1IgT1RIRVIgT0JMSUdBVElPTlMgUkVRVUlSRUQgQlkgU1VDSApDT05UUkFDVCBPUiBBR1JFRU1FTlQuCgpEU1Ugd2lsbCBjbGVhcmx5IGlkZW50aWZ5IHlvdXIgbmFtZShzKSBhcyB0aGUgYXV0aG9yKHMpIG9yIG93bmVyKHMpIG9mIHRoZQpzdWJtaXNzaW9uLCBhbmQgd2lsbCBub3QgbWFrZSBhbnkgYWx0ZXJhdGlvbiwgb3RoZXIgdGhhbiBhcyBhbGxvd2VkIGJ5IHRoaXMKbGljZW5zZSwgdG8geW91ciBzdWJtaXNzaW9uLgo= |
| score |
12.839188 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).