Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis

Descripción del Articulo

The present paper seeks to evaluate the seismic performance of the San Sebastian church and its vulnerability to seismic events. This colonial temple dates back to the 16th century and is located in Cusco, Perú. The church stands out for being one of the first five Andean temples erected in the city...

Descripción completa

Detalles Bibliográficos
Autores: Noel Tapia, María Fernanda, Briceño Melendez, Carolina, Moreira, Susana T., Aguilar, Rafael
Formato: capítulo de libro
Fecha de Publicación:2018
Institución:Universidad San Ignacio de Loyola
Repositorio:USIL-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.usil.edu.pe:20.500.14005/3869
Enlace del recurso:https://hdl.handle.net/20.500.14005/3869
http://doi.org/10.1007/978-3-319-99441-3_157
http://link.springer.com/chapter/10.1007/978-3-319-99441-3_157
Nivel de acceso:acceso embargado
Materia:Sismicidad
Geomorfología
Iglesia (edificio)
id USIL_614de2911c58626152418c3bc3631f28
oai_identifier_str oai:repositorio.usil.edu.pe:20.500.14005/3869
network_acronym_str USIL
network_name_str USIL-Institucional
repository_id_str 3128
spelling 71396c94-5ecc-4543-b963-8196d5d0a7e2-1fffd4d81-ae5a-4a21-81fb-afef3abf614e-15272d7d2-4cb4-4b20-bead-7056c5491d49-14e711d4b-9691-4cd4-923e-59cda5eaac1b-1Noel Tapia, María FernandaBriceño Melendez, CarolinaMoreira, Susana T.Aguilar, Rafael2018-10-11T22:20:51Z2018-10-11T22:20:51Z2019The present paper seeks to evaluate the seismic performance of the San Sebastian church and its vulnerability to seismic events. This colonial temple dates back to the 16th century and is located in Cusco, Perú. The church stands out for being one of the first five Andean temples erected in the city of Cusco and also for being one of the most outstanding expressions of baroque art. Due to its artistic and cultural value, this church was declared National Cultural Heritage in 1972. Unfortunately, the periodic occurrence of seismic events and a fateful fire occurred in 2016 have endangered the survival of the structure and the safety of visitors. Aiming to evaluate the current situation of the church, this research developed a pathological identification through visual inspection and IR thermography as a non-destructive technique. A numerical analysis was also performed by means of a nonlinear pushover analysis that allowed estimating the evolution of the damage and the capacity of the structure in a seismic event. The results of the analysis showed that the main failure mechanisms of the structure would be the decoupling of the church front portion (towers and choir), generating concentrated damage in the arches that support the choir, as well as longitudinal cracks in the nave walls. The seismic capacity related to these failures is around 0.20 g, which is much lower than the recommended demand from the Peruvian code for the region of Cusco – 0.25 g – meaning that the church is highly vulnerable to seismic loads.Revisado por paresapplication/pdf10.1007/978-3-319-99441-3_157https://hdl.handle.net/20.500.14005/3869http://doi.org/10.1007/978-3-319-99441-3_157http://link.springer.com/chapter/10.1007/978-3-319-99441-3_157spaSpringer, ChamStructural Analysis of Historical ConstructionsRILEM Bookseriesinfo:eu-repo/semantics/embargoedAccessUniversidad San Ignacio de LoyolaRepositorio Institucional - USILreponame:USIL-Institucionalinstname:Universidad San Ignacio de Loyolainstacron:USILSismicidadGeomorfologíaIglesia (edificio)Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysisinfo:eu-repo/semantics/bookPartPublication20.500.14005/3869oai:repositorio.usil.edu.pe:20.500.14005/38692023-04-17 09:57:44.122https://repositorio.usil.edu.peRepositorio institucional de la Universidad San Ignacio de Loyolarepositorio.institucional@usil.edu.pe
dc.title.es_ES.fl_str_mv Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
title Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
spellingShingle Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
Noel Tapia, María Fernanda
Sismicidad
Geomorfología
Iglesia (edificio)
title_short Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
title_full Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
title_fullStr Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
title_full_unstemmed Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
title_sort Seismic assessment of the church of San Sebastian in Cusco, Peru by means of pushover nonlinear analysis
author Noel Tapia, María Fernanda
author_facet Noel Tapia, María Fernanda
Briceño Melendez, Carolina
Moreira, Susana T.
Aguilar, Rafael
author_role author
author2 Briceño Melendez, Carolina
Moreira, Susana T.
Aguilar, Rafael
author2_role author
author
author
dc.contributor.author.fl_str_mv Noel Tapia, María Fernanda
Briceño Melendez, Carolina
Moreira, Susana T.
Aguilar, Rafael
dc.subject.es_ES.fl_str_mv Sismicidad
Geomorfología
Iglesia (edificio)
topic Sismicidad
Geomorfología
Iglesia (edificio)
description The present paper seeks to evaluate the seismic performance of the San Sebastian church and its vulnerability to seismic events. This colonial temple dates back to the 16th century and is located in Cusco, Perú. The church stands out for being one of the first five Andean temples erected in the city of Cusco and also for being one of the most outstanding expressions of baroque art. Due to its artistic and cultural value, this church was declared National Cultural Heritage in 1972. Unfortunately, the periodic occurrence of seismic events and a fateful fire occurred in 2016 have endangered the survival of the structure and the safety of visitors. Aiming to evaluate the current situation of the church, this research developed a pathological identification through visual inspection and IR thermography as a non-destructive technique. A numerical analysis was also performed by means of a nonlinear pushover analysis that allowed estimating the evolution of the damage and the capacity of the structure in a seismic event. The results of the analysis showed that the main failure mechanisms of the structure would be the decoupling of the church front portion (towers and choir), generating concentrated damage in the arches that support the choir, as well as longitudinal cracks in the nave walls. The seismic capacity related to these failures is around 0.20 g, which is much lower than the recommended demand from the Peruvian code for the region of Cusco – 0.25 g – meaning that the church is highly vulnerable to seismic loads.
publishDate 2018
dc.date.accessioned.none.fl_str_mv 2018-10-11T22:20:51Z
dc.date.available.none.fl_str_mv 2018-10-11T22:20:51Z
dc.date.issued.fl_str_mv 2019
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/bookPart
format bookPart
dc.identifier.doi.none.fl_str_mv 10.1007/978-3-319-99441-3_157
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14005/3869
http://doi.org/10.1007/978-3-319-99441-3_157
http://link.springer.com/chapter/10.1007/978-3-319-99441-3_157
identifier_str_mv 10.1007/978-3-319-99441-3_157
url https://hdl.handle.net/20.500.14005/3869
http://doi.org/10.1007/978-3-319-99441-3_157
http://link.springer.com/chapter/10.1007/978-3-319-99441-3_157
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.relation.ispartof.en.fl_str_mv Structural Analysis of Historical Constructions
dc.relation.ispartofseries.en.fl_str_mv RILEM Bookseries
dc.rights.es_ES.fl_str_mv info:eu-repo/semantics/embargoedAccess
eu_rights_str_mv embargoedAccess
dc.format.es_ES.fl_str_mv application/pdf
dc.publisher.es_ES.fl_str_mv Springer, Cham
dc.source.es_ES.fl_str_mv Universidad San Ignacio de Loyola
Repositorio Institucional - USIL
dc.source.none.fl_str_mv reponame:USIL-Institucional
instname:Universidad San Ignacio de Loyola
instacron:USIL
instname_str Universidad San Ignacio de Loyola
instacron_str USIL
institution USIL
reponame_str USIL-Institucional
collection USIL-Institucional
repository.name.fl_str_mv Repositorio institucional de la Universidad San Ignacio de Loyola
repository.mail.fl_str_mv repositorio.institucional@usil.edu.pe
_version_ 1846976611090432000
score 13.089325
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).