Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación

Descripción del Articulo

The present investigation studied the influence of time and current density for the removal of Biochemical Oxygen Demand (BOD5) and turbidity of the effluent from the paper machine of the paper company TRUPAL S.A, applying an electrocoagulation treatment. The process was carried out at different tre...

Descripción completa

Detalles Bibliográficos
Autores: Huamán Rodríguez, Aldo Gino, Muñoz Olivera, Melisa
Formato: tesis de grado
Fecha de Publicación:2019
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/14063
Enlace del recurso:https://hdl.handle.net/20.500.14414/14063
Nivel de acceso:acceso abierto
Materia:Electrocoagulación
Efluente de máquina papelera
DBO5
Turbidez
Tiempo
Densidad de corriente
id UNIT_b73ef3973bd6f3eb7f535323681f8d8a
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/14063
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
title Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
spellingShingle Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
Huamán Rodríguez, Aldo Gino
Electrocoagulación
Efluente de máquina papelera
DBO5
Turbidez
Tiempo
Densidad de corriente
title_short Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
title_full Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
title_fullStr Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
title_full_unstemmed Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
title_sort Influencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulación
author Huamán Rodríguez, Aldo Gino
author_facet Huamán Rodríguez, Aldo Gino
Muñoz Olivera, Melisa
author_role author
author2 Muñoz Olivera, Melisa
author2_role author
dc.contributor.advisor.fl_str_mv Saldaña Saavedra, Segundo Juan
dc.contributor.author.fl_str_mv Huamán Rodríguez, Aldo Gino
Muñoz Olivera, Melisa
dc.subject.es_PE.fl_str_mv Electrocoagulación
Efluente de máquina papelera
DBO5
Turbidez
Tiempo
Densidad de corriente
topic Electrocoagulación
Efluente de máquina papelera
DBO5
Turbidez
Tiempo
Densidad de corriente
description The present investigation studied the influence of time and current density for the removal of Biochemical Oxygen Demand (BOD5) and turbidity of the effluent from the paper machine of the paper company TRUPAL S.A, applying an electrocoagulation treatment. The process was carried out at different treatment times (40, 60 and 80 min) and different current density (5, 23; 10, 45; 15, 66 and 20, 90 mA/cm2). A 2, 6 L capacity batch glass material reactor was used, likewise, three iron electrodes were used as cathode and three aluminum electrodes as anode connected in parallel at a distance between electrodes of 1cm. We worked with an established pH of 5 and with a magnetic stirrer to avoid polarization of the sample during the treatment. From the results obtained, it was determined that the increase in time and current density significantly influence and increase the removal percentage for BOD5 and turbidity. Which can be verified with the ANOVA analysis of variance for a 95 % confidence level where there was a higher 99,35 % turbidity removal at a time of 60 min and a current density of 20,90 mA /cm2 likewise a BOD5 removal of 86,22 % was achieved at a time of 80 min and a current density of 10,45 mA / cm2 of the effluent from the paper machine
publishDate 2019
dc.date.accessioned.none.fl_str_mv 2019-09-26T18:57:16Z
dc.date.available.none.fl_str_mv 2019-09-26T18:57:16Z
dc.date.issued.fl_str_mv 2019
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/14063
url https://hdl.handle.net/20.500.14414/14063
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/66e300f2-e74a-4047-9a6d-97474014c17f/download
https://dspace.unitru.edu.pe/bitstreams/2c8e0e7b-a331-4cc6-aef5-304fbe26718d/download
bitstream.checksum.fl_str_mv 0bdfcae8e4f983c533e0d848d7739469
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807289754877689856
spelling Saldaña Saavedra, Segundo JuanHuamán Rodríguez, Aldo GinoMuñoz Olivera, Melisa2019-09-26T18:57:16Z2019-09-26T18:57:16Z2019https://hdl.handle.net/20.500.14414/14063The present investigation studied the influence of time and current density for the removal of Biochemical Oxygen Demand (BOD5) and turbidity of the effluent from the paper machine of the paper company TRUPAL S.A, applying an electrocoagulation treatment. The process was carried out at different treatment times (40, 60 and 80 min) and different current density (5, 23; 10, 45; 15, 66 and 20, 90 mA/cm2). A 2, 6 L capacity batch glass material reactor was used, likewise, three iron electrodes were used as cathode and three aluminum electrodes as anode connected in parallel at a distance between electrodes of 1cm. We worked with an established pH of 5 and with a magnetic stirrer to avoid polarization of the sample during the treatment. From the results obtained, it was determined that the increase in time and current density significantly influence and increase the removal percentage for BOD5 and turbidity. Which can be verified with the ANOVA analysis of variance for a 95 % confidence level where there was a higher 99,35 % turbidity removal at a time of 60 min and a current density of 20,90 mA /cm2 likewise a BOD5 removal of 86,22 % was achieved at a time of 80 min and a current density of 10,45 mA / cm2 of the effluent from the paper machineLa presente investigación estudió la influencia del tiempo y la densidad de corriente para la remoción de Demanda Bioquímica de Oxígeno (DBO5) y turbidez del efluente procedente de la máquina papelera de la empresa papelera TRUPAL S.A, aplicando un tratamiento de electrocoagulación. El proceso se llevó a cabo a diferentes tiempos de tratamiento (40, 60 y 80 min) y diferentes densidad de corriente (5,23; 10,45; 15,66 y 20,90 mA/cm2). Se utilizó un reactor de material de vidrio tipo batch de 2,6 L de capacidad, así mismo, se utilizaron tres electrodos de hierro como cátodo y tres electrodos de aluminio como ánodo conectados en paralelo a una distancia entre electrodos de 1cm. Se trabajó con un pH establecido de 5 y con un agitador magnético para evitar la polarización de la muestra durante el tratamiento. De los resultados obtenidos se determinó que el incremento del tiempo y la densidad de corriente influyen significativamente e incrementan el porcentaje de remoción para DBO5 y turbidez. Ello se puede verificar con el análisis de varianza ANOVA para un nivel de confianza del 95 % donde hubo una mayor remoción de turbidez del 99,35 % a un tiempo de 60 min y una densidad de corriente de 20,90 mA/cm2 así mismo se logró una remoción de DBO5 del 86,22 % a un tiempo de 80 min y una densidad de corriente de 10,45 mA/cm2 del efluente procedente de la máquina papeleraTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUElectrocoagulaciónEfluente de máquina papeleraDBO5TurbidezTiempoDensidad de corrienteInfluencia del tiempo y densidad de corriente para la remoción de DBO y turbidez de efluentes de industrtia papelera por electrocoagulacióninfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngeniero AmbientalIngeniería AmbientalUniversidad Nacional de Trujillo. Facultad de Ingeniería QuímicaORIGINALHuamanRodriguez_A - MunozOlivera_M.pdfHuamanRodriguez_A - MunozOlivera_M.pdfapplication/pdf5242815https://dspace.unitru.edu.pe/bitstreams/66e300f2-e74a-4047-9a6d-97474014c17f/download0bdfcae8e4f983c533e0d848d7739469MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/2c8e0e7b-a331-4cc6-aef5-304fbe26718d/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/14063oai:dspace.unitru.edu.pe:20.500.14414/140632019-10-23 11:53:45.36http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.906419
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).