USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY

Descripción del Articulo

HIGH-FLOW NON-INVASIVE VENTILATION (NIV) DEVICES REDUCE THE MORBIDITY AND MORTALITY OF COVID-19. THE OBJECTIVE WAS TO EVALUATE THE USE OF THE NON-INVASIVE VENTILATION DEVICE WITH HIGH-FLOW HELMET CPAP DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19) HOSPITALIZED IN THE...

Descripción completa

Detalles Bibliográficos
Autores: MANTARI, JOSÉ LUIS, BONIFACIO, DIEGO, HINOSTROZA, FANY PONCE, PANDURO, ROY, OLIDEN, JOSÉ, CUBA, LIZBETH MÓNICA, SALAZAR, JOSÉ LUIS, TITO, JENNY, GARCÍA, JORGE A., BENDEZÚ, MARÍA R., PARIONA-LLANOS, RICARDO, AGUILAR-RAMIREZ, PRISCILIA, ALVARADO, ANGEL T.
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Nacional del Callao
Repositorio:UNAC-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unac.edu.pe:20.500.12952/9910
Enlace del recurso:https://hdl.handle.net/20.500.12952/9910
Nivel de acceso:acceso abierto
Materia:COVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORT
https://purl.org/pe-repo/ocde/ford#2.00.00
id UNAC_80ed496ab6f8c53c54758cbf0bb2a224
oai_identifier_str oai:repositorio.unac.edu.pe:20.500.12952/9910
network_acronym_str UNAC
network_name_str UNAC-Institucional
repository_id_str 2593
spelling MANTARI, JOSÉ LUISBONIFACIO, DIEGOHINOSTROZA, FANY PONCEPANDURO, ROYOLIDEN, JOSÉCUBA, LIZBETH MÓNICASALAZAR, JOSÉ LUISTITO, JENNYGARCÍA, JORGE A.BENDEZÚ, MARÍA R.PARIONA-LLANOS, RICARDOAGUILAR-RAMIREZ, PRISCILIAALVARADO, ANGEL T.2025-02-28T20:39:55Z2025-02-28T20:39:55Z20244280296https://hdl.handle.net/20.500.12952/991010.3897/PHARMACIA.71.E135653HIGH-FLOW NON-INVASIVE VENTILATION (NIV) DEVICES REDUCE THE MORBIDITY AND MORTALITY OF COVID-19. THE OBJECTIVE WAS TO EVALUATE THE USE OF THE NON-INVASIVE VENTILATION DEVICE WITH HIGH-FLOW HELMET CPAP DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19) HOSPITALIZED IN THE EMERGENCY SERVICES OF FIVE HOSPITALS. PROSPECTIVE MULTICENTER AND CROSS-SECTIONAL OBSERVATIONAL STUDY FROM FIVE HOSPITALS FROM JULY TO AUGUST 2020. 19 PATIENTS WERE RECRUITED AND DIVIDED INTO TWO GROUPS (G-1 N = 10; G-2 N = 9) APPLYING CLINICAL AND GASOMETRIC PARAMETERS AS INDICATORS OF DISEASE EVOLUTION UPON HOSPITAL ADMISSION AND WITHIN 24 HOURS. A PROGRESSIVE INCREASE IN THESE PARAMETERS WAS OBSERVED IN THOSE PATIENTS WHO USED THE NIV CPAP HELMET WITHIN THE FIRST 24 HOURS. IN G-01, IMPROVEMENT WAS EVIDENT IN 90% (N = 9/10): PAO2 (RANGE 48–137; AVERAGE: 82.49 ± 8.07; P-VALUE = 0.008), CO2 (25.2–51.0; 36.62 ± 2.62; P-VALUE P = 0.327), AND THE PAO2/FIO2 COEFFICIENT (87–318; 191.5 ± 18.68). 10% OF PATIENTS DID NOT PROGRESS OPTIMALLY, BEING SUBJECTED TO ENDOTRACHEAL INTUBATION AND INVASIVE MECHANICAL VENTILATION. IN G-02 THE VALUES WERE %SATO2 (RANGE 92–98; 96 ± 0.76) AND THE SAO2/FIO2 COEFFICIENT (214–228; 223.2 ± 1.80), INDICATING SIGNIFICANT IMPROVEMENT WITHIN 24 HOURS (P < 0.001). IT IS CONCLUDED THAT THE USE OF THE CPAP HELMET NON-INVASIVE VENTILATION (NIV) DEVICE CONTRIBUTES TO IMPROVING GASOMETRIC VALUES AND CLINICAL CONDITION. BEING AN ALTERNATIVE TO RECOVER TYPICAL CASES OF COVID-19 IN ALL HOSPITALS IN PERU. COPYRIGHT MANTARI JL ET AL. THIS IS AN OPEN ACCESS ARTICLE DISTRIBUTED UNDER THE TERMS OF THE CREATIVE COMMONS ATTRIBUTION LICENSE (CC-BY 4.0), WHICH PERMITS UNRESTRICTED USE, DISTRIBUTION, AND REPRODUCTION IN ANY MEDIUM, PROVIDED THE ORIGINAL AUTHOR AND SOURCE ARE CREDITED.application/pdfspaPHARMACIAinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/COVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORThttps://purl.org/pe-repo/ocde/ford#2.00.00USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDYinfo:eu-repo/semantics/articlereponame:UNAC-Institucionalinstname:Universidad Nacional del Callaoinstacron:UNAC20.500.12952/9910oai:repositorio.unac.edu.pe:20.500.12952/99102025-02-28 15:39:55.766https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessmetadata.onlyhttps://repositorio.unac.edu.peRepositorio de la Universidad Nacional del Callaodspace-help@myu.edu
dc.title.es_PE.fl_str_mv USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
title USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
spellingShingle USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
MANTARI, JOSÉ LUIS
COVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORT
https://purl.org/pe-repo/ocde/ford#2.00.00
title_short USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
title_full USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
title_fullStr USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
title_full_unstemmed USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
title_sort USE OF THE HIGH-FLOW HELMET CPAP NON-INVASIVE VENTILATION DEVICE DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19): A PROSPECTIVE MULTICENTER STUDY
author MANTARI, JOSÉ LUIS
author_facet MANTARI, JOSÉ LUIS
BONIFACIO, DIEGO
HINOSTROZA, FANY PONCE
PANDURO, ROY
OLIDEN, JOSÉ
CUBA, LIZBETH MÓNICA
SALAZAR, JOSÉ LUIS
TITO, JENNY
GARCÍA, JORGE A.
BENDEZÚ, MARÍA R.
PARIONA-LLANOS, RICARDO
AGUILAR-RAMIREZ, PRISCILIA
ALVARADO, ANGEL T.
author_role author
author2 BONIFACIO, DIEGO
HINOSTROZA, FANY PONCE
PANDURO, ROY
OLIDEN, JOSÉ
CUBA, LIZBETH MÓNICA
SALAZAR, JOSÉ LUIS
TITO, JENNY
GARCÍA, JORGE A.
BENDEZÚ, MARÍA R.
PARIONA-LLANOS, RICARDO
AGUILAR-RAMIREZ, PRISCILIA
ALVARADO, ANGEL T.
author2_role author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv MANTARI, JOSÉ LUIS
BONIFACIO, DIEGO
HINOSTROZA, FANY PONCE
PANDURO, ROY
OLIDEN, JOSÉ
CUBA, LIZBETH MÓNICA
SALAZAR, JOSÉ LUIS
TITO, JENNY
GARCÍA, JORGE A.
BENDEZÚ, MARÍA R.
PARIONA-LLANOS, RICARDO
AGUILAR-RAMIREZ, PRISCILIA
ALVARADO, ANGEL T.
dc.subject.es_PE.fl_str_mv COVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORT
topic COVID-19, CPAP HELMET, HIGH-FLOW VENTILATION, RESPIRATORY FAILURE, VENTILATORY SUPPORT
https://purl.org/pe-repo/ocde/ford#2.00.00
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.00.00
description HIGH-FLOW NON-INVASIVE VENTILATION (NIV) DEVICES REDUCE THE MORBIDITY AND MORTALITY OF COVID-19. THE OBJECTIVE WAS TO EVALUATE THE USE OF THE NON-INVASIVE VENTILATION DEVICE WITH HIGH-FLOW HELMET CPAP DESIGNED IN PERU IN PATIENTS WITH SEVERE ACUTE RESPIRATORY SYNDROME (COVID-19) HOSPITALIZED IN THE EMERGENCY SERVICES OF FIVE HOSPITALS. PROSPECTIVE MULTICENTER AND CROSS-SECTIONAL OBSERVATIONAL STUDY FROM FIVE HOSPITALS FROM JULY TO AUGUST 2020. 19 PATIENTS WERE RECRUITED AND DIVIDED INTO TWO GROUPS (G-1 N = 10; G-2 N = 9) APPLYING CLINICAL AND GASOMETRIC PARAMETERS AS INDICATORS OF DISEASE EVOLUTION UPON HOSPITAL ADMISSION AND WITHIN 24 HOURS. A PROGRESSIVE INCREASE IN THESE PARAMETERS WAS OBSERVED IN THOSE PATIENTS WHO USED THE NIV CPAP HELMET WITHIN THE FIRST 24 HOURS. IN G-01, IMPROVEMENT WAS EVIDENT IN 90% (N = 9/10): PAO2 (RANGE 48–137; AVERAGE: 82.49 ± 8.07; P-VALUE = 0.008), CO2 (25.2–51.0; 36.62 ± 2.62; P-VALUE P = 0.327), AND THE PAO2/FIO2 COEFFICIENT (87–318; 191.5 ± 18.68). 10% OF PATIENTS DID NOT PROGRESS OPTIMALLY, BEING SUBJECTED TO ENDOTRACHEAL INTUBATION AND INVASIVE MECHANICAL VENTILATION. IN G-02 THE VALUES WERE %SATO2 (RANGE 92–98; 96 ± 0.76) AND THE SAO2/FIO2 COEFFICIENT (214–228; 223.2 ± 1.80), INDICATING SIGNIFICANT IMPROVEMENT WITHIN 24 HOURS (P < 0.001). IT IS CONCLUDED THAT THE USE OF THE CPAP HELMET NON-INVASIVE VENTILATION (NIV) DEVICE CONTRIBUTES TO IMPROVING GASOMETRIC VALUES AND CLINICAL CONDITION. BEING AN ALTERNATIVE TO RECOVER TYPICAL CASES OF COVID-19 IN ALL HOSPITALS IN PERU. COPYRIGHT MANTARI JL ET AL. THIS IS AN OPEN ACCESS ARTICLE DISTRIBUTED UNDER THE TERMS OF THE CREATIVE COMMONS ATTRIBUTION LICENSE (CC-BY 4.0), WHICH PERMITS UNRESTRICTED USE, DISTRIBUTION, AND REPRODUCTION IN ANY MEDIUM, PROVIDED THE ORIGINAL AUTHOR AND SOURCE ARE CREDITED.
publishDate 2024
dc.date.accessioned.none.fl_str_mv 2025-02-28T20:39:55Z
dc.date.available.none.fl_str_mv 2025-02-28T20:39:55Z
dc.date.issued.fl_str_mv 2024
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.issn.none.fl_str_mv 4280296
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12952/9910
dc.identifier.doi.none.fl_str_mv 10.3897/PHARMACIA.71.E135653
identifier_str_mv 4280296
10.3897/PHARMACIA.71.E135653
url https://hdl.handle.net/20.500.12952/9910
dc.language.iso.none.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv PHARMACIA
publisher.none.fl_str_mv PHARMACIA
dc.source.none.fl_str_mv reponame:UNAC-Institucional
instname:Universidad Nacional del Callao
instacron:UNAC
instname_str Universidad Nacional del Callao
instacron_str UNAC
institution UNAC
reponame_str UNAC-Institucional
collection UNAC-Institucional
repository.name.fl_str_mv Repositorio de la Universidad Nacional del Callao
repository.mail.fl_str_mv dspace-help@myu.edu
_version_ 1846066496749436928
score 13.0768795
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).