Measurement and analysis of air quality in temporary shelters on three continents
Descripción del Articulo
Millions of displaced people are housed in shelters that generally consist of a single room, meaning that activities including cooking, sleeping and socializing all take place in the same space. Therefore, indoor air quality can be poor, resulting in estimated 20,000 displaced people dying premature...
Autores: | , , , , , , , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad de Lima |
Repositorio: | ULIMA-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.ulima.edu.pe:20.500.12724/11578 |
Enlace del recurso: | https://hdl.handle.net/20.500.12724/11578 https://doi.org/10.1016/j.buildenv.2020.107259 |
Nivel de acceso: | acceso abierto |
Materia: | Calidad del aire Refugios Compuestos orgánicos Air quality Shelters Organic compounds https://purl.org/pe-repo/ocde/ford#6.04.08 |
id |
RULI_f7833b97cb1ab7e9a066be3362cfd8f9 |
---|---|
oai_identifier_str |
oai:repositorio.ulima.edu.pe:20.500.12724/11578 |
network_acronym_str |
RULI |
network_name_str |
ULIMA-Institucional |
repository_id_str |
3883 |
dc.title.en_EN.fl_str_mv |
Measurement and analysis of air quality in temporary shelters on three continents |
title |
Measurement and analysis of air quality in temporary shelters on three continents |
spellingShingle |
Measurement and analysis of air quality in temporary shelters on three continents Albadra, Dima Calidad del aire Refugios Compuestos orgánicos Air quality Shelters Organic compounds https://purl.org/pe-repo/ocde/ford#6.04.08 |
title_short |
Measurement and analysis of air quality in temporary shelters on three continents |
title_full |
Measurement and analysis of air quality in temporary shelters on three continents |
title_fullStr |
Measurement and analysis of air quality in temporary shelters on three continents |
title_full_unstemmed |
Measurement and analysis of air quality in temporary shelters on three continents |
title_sort |
Measurement and analysis of air quality in temporary shelters on three continents |
author |
Albadra, Dima |
author_facet |
Albadra, Dima Kuchai, N. Acevedo De los Ríos, Alejandra Rondinel Oviedo, Daniel Ricardo Coley, David Alexander da Silva, Carla Florbela F.P. Rana, Chetas Mower, K. Dengel, Andy C. Maskell, Dan Ball, R. J. |
author_role |
author |
author2 |
Kuchai, N. Acevedo De los Ríos, Alejandra Rondinel Oviedo, Daniel Ricardo Coley, David Alexander da Silva, Carla Florbela F.P. Rana, Chetas Mower, K. Dengel, Andy C. Maskell, Dan Ball, R. J. |
author2_role |
author author author author author author author author author author |
dc.contributor.other.none.fl_str_mv |
Acevedo De los Ríos, Alejandra Rondinel Oviedo, Daniel Ricardo |
dc.contributor.author.fl_str_mv |
Albadra, Dima Kuchai, N. Acevedo De los Ríos, Alejandra Rondinel Oviedo, Daniel Ricardo Coley, David Alexander da Silva, Carla Florbela F.P. Rana, Chetas Mower, K. Dengel, Andy C. Maskell, Dan Ball, R. J. |
dc.subject.es_PE.fl_str_mv |
Calidad del aire Refugios Compuestos orgánicos |
topic |
Calidad del aire Refugios Compuestos orgánicos Air quality Shelters Organic compounds https://purl.org/pe-repo/ocde/ford#6.04.08 |
dc.subject.en_EN.fl_str_mv |
Air quality Shelters Organic compounds |
dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#6.04.08 |
description |
Millions of displaced people are housed in shelters that generally consist of a single room, meaning that activities including cooking, sleeping and socializing all take place in the same space. Therefore, indoor air quality can be poor, resulting in estimated 20,000 displaced people dying prematurely every year. Very few studies considered the issue and all within one country. This paper describes the first comprehensive study investigating air quality in shelters by looking at Volatile Organic Compounds (VOCs), Particulate Matter (PM), and CO2 in ten locations within Peru, Ethiopia, Djibouti, Jordan, Turkey and Bangladesh. It has the aim of: (i) discovering how widespread the issue is, (ii) identifying some of the causes, (iii) whether it is linked to cultural and behavioural factors, (iv) location and climate, or (v) shelters’ materials or design. Results revealed very harmful levels of pollutants that are often linked to excess mortality - with total VOC concentrations as high as 102400 µgm-3 and PM over 3000 µgm-3. The reasons for these concentrations were complex, multifaceted and setting-specific. However, it was an issue in both simple self-built shelters and mass-manufactured designs, and across all climates and cultures. In all cases, conditions could be greatly improved by improving airflow as windows were frequently blocked for various reasons. Therefore, airflow should be explicitly considered, whilst being cognisant of the local context; and when cooking is likely to occur indoors, chimneys must be fitted. |
publishDate |
2020 |
dc.date.accessioned.none.fl_str_mv |
2020-09-24T17:06:56Z |
dc.date.available.none.fl_str_mv |
2020-09-24T17:06:56Z |
dc.date.issued.fl_str_mv |
2020 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.other.none.fl_str_mv |
Artículo en Scopus |
format |
article |
dc.identifier.citation.es_PE.fl_str_mv |
Albadra, D., Kuchai, N., Acevedo-De-los-Ríos, A., Rondinel-Oviedo, D. R., Coley, D. A., da Silva, C. F. F. P., Rana, C., Mower, K., Dengel, A. C., Maskell, D., & Ball, R. J. (2020). Measurement and analysis of air quality in temporary shelters on three continents. Building and Environment, 185, November 2020. https://doi.org/10.1016/j.buildenv.2020.107259 |
dc.identifier.issn.none.fl_str_mv |
0360-1323 |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12724/11578 |
dc.identifier.journal.none.fl_str_mv |
Building and EnvironmentBuilding and Environment |
dc.identifier.isni.none.fl_str_mv |
0000000121541816 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1016/j.buildenv.2020.107259 |
dc.identifier.scopusid.none.fl_str_mv |
2-s2.0-85090827742 |
identifier_str_mv |
Albadra, D., Kuchai, N., Acevedo-De-los-Ríos, A., Rondinel-Oviedo, D. R., Coley, D. A., da Silva, C. F. F. P., Rana, C., Mower, K., Dengel, A. C., Maskell, D., & Ball, R. J. (2020). Measurement and analysis of air quality in temporary shelters on three continents. Building and Environment, 185, November 2020. https://doi.org/10.1016/j.buildenv.2020.107259 0360-1323 Building and EnvironmentBuilding and Environment 0000000121541816 2-s2.0-85090827742 |
url |
https://hdl.handle.net/20.500.12724/11578 https://doi.org/10.1016/j.buildenv.2020.107259 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.none.fl_str_mv |
urn:issn:0360-1323 |
dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.*.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
dc.format.none.fl_str_mv |
application/html |
dc.publisher.none.fl_str_mv |
Elsevier |
dc.publisher.country.none.fl_str_mv |
GB |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
Repositorio Institucional - Ulima Universidad de Lima reponame:ULIMA-Institucional instname:Universidad de Lima instacron:ULIMA |
instname_str |
Universidad de Lima |
instacron_str |
ULIMA |
institution |
ULIMA |
reponame_str |
ULIMA-Institucional |
collection |
ULIMA-Institucional |
bitstream.url.fl_str_mv |
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11578/3/license.txt https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11578/2/license_rdf |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 80294ba9ff4c5b4f07812ee200fbc42f |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Universidad de Lima |
repository.mail.fl_str_mv |
repositorio@ulima.edu.pe |
_version_ |
1845977463085072384 |
spelling |
Albadra, DimaKuchai, N.Acevedo De los Ríos, AlejandraRondinel Oviedo, Daniel RicardoColey, David Alexanderda Silva, Carla Florbela F.P.Rana, ChetasMower, K.Dengel, Andy C.Maskell, DanBall, R. J.Acevedo De los Ríos, AlejandraRondinel Oviedo, Daniel Ricardo2020-09-24T17:06:56Z2020-09-24T17:06:56Z2020Albadra, D., Kuchai, N., Acevedo-De-los-Ríos, A., Rondinel-Oviedo, D. R., Coley, D. A., da Silva, C. F. F. P., Rana, C., Mower, K., Dengel, A. C., Maskell, D., & Ball, R. J. (2020). Measurement and analysis of air quality in temporary shelters on three continents. Building and Environment, 185, November 2020. https://doi.org/10.1016/j.buildenv.2020.1072590360-1323https://hdl.handle.net/20.500.12724/11578Building and EnvironmentBuilding and Environment0000000121541816https://doi.org/10.1016/j.buildenv.2020.1072592-s2.0-85090827742Millions of displaced people are housed in shelters that generally consist of a single room, meaning that activities including cooking, sleeping and socializing all take place in the same space. Therefore, indoor air quality can be poor, resulting in estimated 20,000 displaced people dying prematurely every year. Very few studies considered the issue and all within one country. This paper describes the first comprehensive study investigating air quality in shelters by looking at Volatile Organic Compounds (VOCs), Particulate Matter (PM), and CO2 in ten locations within Peru, Ethiopia, Djibouti, Jordan, Turkey and Bangladesh. It has the aim of: (i) discovering how widespread the issue is, (ii) identifying some of the causes, (iii) whether it is linked to cultural and behavioural factors, (iv) location and climate, or (v) shelters’ materials or design. Results revealed very harmful levels of pollutants that are often linked to excess mortality - with total VOC concentrations as high as 102400 µgm-3 and PM over 3000 µgm-3. The reasons for these concentrations were complex, multifaceted and setting-specific. However, it was an issue in both simple self-built shelters and mass-manufactured designs, and across all climates and cultures. In all cases, conditions could be greatly improved by improving airflow as windows were frequently blocked for various reasons. Therefore, airflow should be explicitly considered, whilst being cognisant of the local context; and when cooking is likely to occur indoors, chimneys must be fitted.application/htmlengElsevierGBurn:issn:0360-1323info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Repositorio Institucional - UlimaUniversidad de Limareponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMACalidad del aireRefugiosCompuestos orgánicosAir qualitySheltersOrganic compoundshttps://purl.org/pe-repo/ocde/ford#6.04.08Measurement and analysis of air quality in temporary shelters on three continentsinfo:eu-repo/semantics/articleArtículo en ScopusAcevedo De los Ríos, Alejandra (Arquitectura)Rondinel Oviedo, Daniel Ricardo (Arquitectura)Acevedo De los Ríos, Alejandra (Scientific Research Institute, University of Lima)Rondinel Oviedo, Daniel Ricardo (Scientific Research Institute, University of Lima)OILICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11578/3/license.txt8a4605be74aa9ea9d79846c1fba20a33MD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81037https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11578/2/license_rdf80294ba9ff4c5b4f07812ee200fbc42fMD5220.500.12724/11578oai:repositorio.ulima.edu.pe:20.500.12724/115782024-10-23 12:04:42.192Repositorio Universidad de Limarepositorio@ulima.edu.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 |
score |
13.024418 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).