Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua

Descripción del Articulo

The pollution caused by the use of water in many activities of human beings, has taken us to the need of using new technologies to the removal of contaminants from wastewater, one of them is the electrocoagulation. In this research we suggest the construction of an electrocoagulation reactor to eval...

Descripción completa

Detalles Bibliográficos
Autor: Aguilar Ascón, Edwar
Formato: artículo
Fecha de Publicación:2015
Institución:Universidad de Lima
Repositorio:ULIMA-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.ulima.edu.pe:20.500.12724/2347
Enlace del recurso:https://hdl.handle.net/20.500.12724/2347
https://doi.org/10.15381/iigeo.v18i35.11843
Nivel de acceso:acceso abierto
Materia:Electrocoagulación
Tratamiento del agua
Aguas residuales
Electrocoagulation
Water treatment
Sewage
id RULI_efa9741f9a95319df332048ed50303df
oai_identifier_str oai:repositorio.ulima.edu.pe:20.500.12724/2347
network_acronym_str RULI
network_name_str ULIMA-Institucional
repository_id_str 3883
dc.title.es_PE.fl_str_mv Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
dc.title.alternative.es_ES.fl_str_mv Efficiency’s evaluation of an electrocoagulation cell at scale laboratory for water treatment
title Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
spellingShingle Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
Aguilar Ascón, Edwar
Electrocoagulación
Tratamiento del agua
Aguas residuales
Electrocoagulation
Water treatment
Sewage
title_short Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
title_full Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
title_fullStr Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
title_full_unstemmed Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
title_sort Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua
author Aguilar Ascón, Edwar
author_facet Aguilar Ascón, Edwar
author_role author
dc.contributor.other.none.fl_str_mv Aguilar Ascón, Edwar
dc.contributor.author.fl_str_mv Aguilar Ascón, Edwar
dc.subject.none.fl_str_mv Electrocoagulación
Tratamiento del agua
Aguas residuales
Electrocoagulation
Water treatment
Sewage
topic Electrocoagulación
Tratamiento del agua
Aguas residuales
Electrocoagulation
Water treatment
Sewage
description The pollution caused by the use of water in many activities of human beings, has taken us to the need of using new technologies to the removal of contaminants from wastewater, one of them is the electrocoagulation. In this research we suggest the construction of an electrocoagulation reactor to evaluate the efficiency in the removal of COD (Chemical Oxygen Demand) from wastewater coming from the painting industry; it also wants to determine the best conditions of pH, conductivity, electric intensity and time of treatment. Based on the results we’ve gotten in the treatment of effluent with electrocoagulation, we determined an average efficiency in the 87 % of COD removal. This optimum ranges were gotten with an electrical intensity of I = 5 amperes, with the natural pH of the effluent in 7,12 and a 15 minutes treatment time, with which we accomplish the environmental compliance of the country. Other important aspect we ´ve seen in this research was the quality of the sludge produced in the treatment, with much more compact appearance than a physicochemical or biological sludge.
publishDate 2015
dc.date.accessioned.none.fl_str_mv 2016-11-29T22:14:35Z
dc.date.issued.fl_str_mv 2015
dc.type.none.fl_str_mv info:eu-repo/semantics/article
dc.type.other.none.fl_str_mv Artículo
format article
dc.identifier.citation.es_ES.fl_str_mv Aguilar, E. (2015). Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua. Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalurgia Y Geográfica, 18(35), 69-73. Recuperado de https://doi.org/10.15381/iigeo.v18i35.11843
dc.identifier.issn.none.fl_str_mv 1561-0888
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12724/2347
dc.identifier.journal.none.fl_str_mv Revista del Instituto de Investigaciones de la Facultad de Geología, Minas, Metalurgia y Ciencias Geográfica
dc.identifier.eissn.es.fl_str_mv 1682-3087
dc.identifier.doi.none.fl_str_mv https://doi.org/10.15381/iigeo.v18i35.11843
identifier_str_mv Aguilar, E. (2015). Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua. Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalurgia Y Geográfica, 18(35), 69-73. Recuperado de https://doi.org/10.15381/iigeo.v18i35.11843
1561-0888
Revista del Instituto de Investigaciones de la Facultad de Geología, Minas, Metalurgia y Ciencias Geográfica
1682-3087
url https://hdl.handle.net/20.500.12724/2347
https://doi.org/10.15381/iigeo.v18i35.11843
dc.language.iso.none.fl_str_mv spa
language spa
dc.relation.uri.none.fl_str_mv https://doi.org/10.15381/iigeo.v18i35.11843
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.publisher.country.none.fl_str_mv PE
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Repositorio Institucional - Ulima
Universidad de Lima
reponame:ULIMA-Institucional
instname:Universidad de Lima
instacron:ULIMA
instname_str Universidad de Lima
instacron_str ULIMA
institution ULIMA
reponame_str ULIMA-Institucional
collection ULIMA-Institucional
bitstream.url.fl_str_mv https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/1/Aguilar_Ascon_Edwar.pdf
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/2/license.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/3/Aguilar_Ascon_Edwar.pdf.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/4/Aguilar_Ascon_Edwar.pdf.jpg
bitstream.checksum.fl_str_mv dbb51bb90744a70846b33011725bc8fd
8a4605be74aa9ea9d79846c1fba20a33
4ce19390edea68182b7a244b7cea77d6
3760300ff5ee06055f1900f5bfa47c39
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Universidad de Lima
repository.mail.fl_str_mv repositorio@ulima.edu.pe
_version_ 1849149186250899456
spelling Aguilar Ascón, EdwarAguilar Ascón, Edwar2016-11-29T22:14:35Z2015Aguilar, E. (2015). Evaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de agua. Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalurgia Y Geográfica, 18(35), 69-73. Recuperado de https://doi.org/10.15381/iigeo.v18i35.118431561-0888https://hdl.handle.net/20.500.12724/2347Revista del Instituto de Investigaciones de la Facultad de Geología, Minas, Metalurgia y Ciencias Geográfica1682-3087https://doi.org/10.15381/iigeo.v18i35.11843The pollution caused by the use of water in many activities of human beings, has taken us to the need of using new technologies to the removal of contaminants from wastewater, one of them is the electrocoagulation. In this research we suggest the construction of an electrocoagulation reactor to evaluate the efficiency in the removal of COD (Chemical Oxygen Demand) from wastewater coming from the painting industry; it also wants to determine the best conditions of pH, conductivity, electric intensity and time of treatment. Based on the results we’ve gotten in the treatment of effluent with electrocoagulation, we determined an average efficiency in the 87 % of COD removal. This optimum ranges were gotten with an electrical intensity of I = 5 amperes, with the natural pH of the effluent in 7,12 and a 15 minutes treatment time, with which we accomplish the environmental compliance of the country. Other important aspect we ´ve seen in this research was the quality of the sludge produced in the treatment, with much more compact appearance than a physicochemical or biological sludge.La contaminación causada por el uso del agua en muchas de las actividades del ser humano nos lleva a la necesidad de utilizar nuevas tecnologías para remoción de contaminantes de las aguas residuales; una de ellas es la electrocoagulación. En este estudio se planteó construir un reactor de electrocoagulación para evaluar la eficiencia en la remoción de la DQO (demanda química de oxígeno) de aguas residuales provenientes de la industria de pintura, así como determinar las mejores condiciones de pH, conductividad, intensidad de corriente y tiempo de tratamiento. En base a los resultados obtenidos al realizar el trata-miento del efluente con electrocoagulación, se determinó una eficiencia promedio del 87 % en la remoción de la DQO. Estos valores óptimos de operación se obtuvieron con una intensidad de corriente I= 5 amperios, con el pH natural del efluente de 7,12 y un tiempo de tratamiento de 15 minutos, con lo cual se cumple la normativa ambiental vigente en el país. Otro aspecto importante observado en este estudio fue la calidad del lodo producido en el tratamiento, de aspecto mucho más compacto que un lodo físicoquímico o biológico.Revisión por paresapplication/pdfspaUniversidad Nacional Mayor de San MarcosPEhttps://doi.org/10.15381/iigeo.v18i35.11843info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Repositorio Institucional - UlimaUniversidad de Limareponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMAElectrocoagulaciónTratamiento del aguaAguas residualesElectrocoagulationWater treatmentSewageEvaluación de la eficiencia de una celda de electrocoagulación a escala laboratorio para el tratamiento de aguaEfficiency’s evaluation of an electrocoagulation cell at scale laboratory for water treatmentinfo:eu-repo/semantics/articleArtículoORIGINALAguilar_Ascon_Edwar.pdfAguilar_Ascon_Edwar.pdfDescargarapplication/pdf371407https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/1/Aguilar_Ascon_Edwar.pdfdbb51bb90744a70846b33011725bc8fdMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTAguilar_Ascon_Edwar.pdf.txtAguilar_Ascon_Edwar.pdf.txtExtracted texttext/plain19201https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/3/Aguilar_Ascon_Edwar.pdf.txt4ce19390edea68182b7a244b7cea77d6MD53THUMBNAILAguilar_Ascon_Edwar.pdf.jpgAguilar_Ascon_Edwar.pdf.jpgGenerated Thumbnailimage/jpeg13832https://repositorio.ulima.edu.pe/bitstream/20.500.12724/2347/4/Aguilar_Ascon_Edwar.pdf.jpg3760300ff5ee06055f1900f5bfa47c39MD5420.500.12724/2347oai:repositorio.ulima.edu.pe:20.500.12724/23472025-11-08 11:42:01.939Repositorio Universidad de Limarepositorio@ulima.edu.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
score 13.067735
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).