Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization
Descripción del Articulo
This study is focused on reducing total chromium level in tannery wastewater through the electrocoagulation process, in order to comply with the maximum permissible limits (MPL) and to determine the effects from its main operating factors. For this purpose, a batch electrocoagulation reactor was man...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2024 |
| Institución: | Universidad de Lima |
| Repositorio: | ULIMA-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.ulima.edu.pe:20.500.12724/20034 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12724/20034 https://doi.org/10.1016/j.heliyon.2024.e24647 |
| Nivel de acceso: | acceso abierto |
| Materia: | Sewage Chromium Factory and trade waste Iron electrodes Electrocoagulation Coagulation Flocculation Hydrogen Tanning Water treatment Sewage disposal Environmental protection |
| id |
RULI_eddd35a82139bad12949157b39074a66 |
|---|---|
| oai_identifier_str |
oai:repositorio.ulima.edu.pe:20.500.12724/20034 |
| network_acronym_str |
RULI |
| network_name_str |
ULIMA-Institucional |
| repository_id_str |
3883 |
| spelling |
Aguilar Ascón E.Marrufo-Saldaña L.Neyra-Ascón W.Aguilar Ascón, EdwarNeyra Ascón, Walter2024-03-06T20:14:25Z2024-03-06T20:14:25Z2024Aguilar, E., Marrufo, L., Neyra, W. (2024). Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization. Helyon. https://doi.org/10.1016/j.heliyon.2024.e246472405-8440https://hdl.handle.net/20.500.12724/20034Heliyon0000000121541816https://doi.org/10.1016/j.heliyon.2024.e246472-s2.0-85184761173This study is focused on reducing total chromium level in tannery wastewater through the electrocoagulation process, in order to comply with the maximum permissible limits (MPL) and to determine the effects from its main operating factors. For this purpose, a batch electrocoagulation reactor was manufactured using iron electrodes. Next, the response surface methodology was applied in the experimental design using a Box–Behnken design (BBD) with three factors: current intensity, treatment time, and level. In addition, the total chromium removal percentage was taken as a response variable.application/htmlengElsevierNLurn:issn:2405-8440info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Repositorio Institucional - UlimaUniversidad de Limareponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMASewageChromiumFactory and trade wasteIron electrodesElectrocoagulationCoagulationFlocculationHydrogenTanningWater treatmentSewage disposalEnvironmental protectionEnhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimizationinfo:eu-repo/semantics/articleArtículo en ScopusAguilar Ascón, Edwar (Programa de Estudios Generales)Neyra Ascón, Walter (No figura en la lista del año 2023)Aguilar Ascón, Edwar (Universidad de Lima, Instituto de Investigación Científica, Grupo de Investigación en Tecnologías Exponenciales, Estudios Generales)Neyra Ascón, Walter (Universidad de Lima, Instituto de Investigación Científica)OI20.500.12724/20034oai:repositorio.ulima.edu.pe:20.500.12724/200342025-08-11 15:06:24.818Repositorio Universidad de Limarepositorio@ulima.edu.pe |
| dc.title.en_EN.fl_str_mv |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| title |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| spellingShingle |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization Aguilar Ascón E. Sewage Chromium Factory and trade waste Iron electrodes Electrocoagulation Coagulation Flocculation Hydrogen Tanning Water treatment Sewage disposal Environmental protection |
| title_short |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| title_full |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| title_fullStr |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| title_full_unstemmed |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| title_sort |
Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization |
| author |
Aguilar Ascón E. |
| author_facet |
Aguilar Ascón E. Marrufo-Saldaña L. Neyra-Ascón W. |
| author_role |
author |
| author2 |
Marrufo-Saldaña L. Neyra-Ascón W. |
| author2_role |
author author |
| dc.contributor.other.none.fl_str_mv |
Aguilar Ascón, Edwar Neyra Ascón, Walter |
| dc.contributor.author.fl_str_mv |
Aguilar Ascón E. Marrufo-Saldaña L. Neyra-Ascón W. |
| dc.subject.en_EN.fl_str_mv |
Sewage Chromium Factory and trade waste Iron electrodes Electrocoagulation Coagulation Flocculation Hydrogen Tanning Water treatment Sewage disposal Environmental protection |
| topic |
Sewage Chromium Factory and trade waste Iron electrodes Electrocoagulation Coagulation Flocculation Hydrogen Tanning Water treatment Sewage disposal Environmental protection |
| description |
This study is focused on reducing total chromium level in tannery wastewater through the electrocoagulation process, in order to comply with the maximum permissible limits (MPL) and to determine the effects from its main operating factors. For this purpose, a batch electrocoagulation reactor was manufactured using iron electrodes. Next, the response surface methodology was applied in the experimental design using a Box–Behnken design (BBD) with three factors: current intensity, treatment time, and level. In addition, the total chromium removal percentage was taken as a response variable. |
| publishDate |
2024 |
| dc.date.accessioned.none.fl_str_mv |
2024-03-06T20:14:25Z |
| dc.date.available.none.fl_str_mv |
2024-03-06T20:14:25Z |
| dc.date.issued.fl_str_mv |
2024 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.other.none.fl_str_mv |
Artículo en Scopus |
| format |
article |
| dc.identifier.citation.es_PE.fl_str_mv |
Aguilar, E., Marrufo, L., Neyra, W. (2024). Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization. Helyon. https://doi.org/10.1016/j.heliyon.2024.e24647 |
| dc.identifier.issn.none.fl_str_mv |
2405-8440 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12724/20034 |
| dc.identifier.journal.none.fl_str_mv |
Heliyon |
| dc.identifier.isni.none.fl_str_mv |
0000000121541816 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1016/j.heliyon.2024.e24647 |
| dc.identifier.scopusid.none.fl_str_mv |
2-s2.0-85184761173 |
| identifier_str_mv |
Aguilar, E., Marrufo, L., Neyra, W. (2024). Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization. Helyon. https://doi.org/10.1016/j.heliyon.2024.e24647 2405-8440 Heliyon 0000000121541816 2-s2.0-85184761173 |
| url |
https://hdl.handle.net/20.500.12724/20034 https://doi.org/10.1016/j.heliyon.2024.e24647 |
| dc.language.iso.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
urn:issn:2405-8440 |
| dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| dc.format.none.fl_str_mv |
application/html |
| dc.publisher.none.fl_str_mv |
Elsevier |
| dc.publisher.country.none.fl_str_mv |
NL |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
Repositorio Institucional - Ulima Universidad de Lima reponame:ULIMA-Institucional instname:Universidad de Lima instacron:ULIMA |
| instname_str |
Universidad de Lima |
| instacron_str |
ULIMA |
| institution |
ULIMA |
| reponame_str |
ULIMA-Institucional |
| collection |
ULIMA-Institucional |
| repository.name.fl_str_mv |
Repositorio Universidad de Lima |
| repository.mail.fl_str_mv |
repositorio@ulima.edu.pe |
| _version_ |
1847246088196587520 |
| score |
12.888917 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).