Diseño de un estimulador para generar la succión en recién nacidos prematuros

Descripción del Articulo

This work raises a solution for the development of the sucking reflex in premature infants. This solution is based on a computer that uses a system of control of negative pressure applied directly in a pacifier common through a dock. In turn, this process is performed using a generator of waves that...

Descripción completa

Detalles Bibliográficos
Autor: Yika Tuesta, Alberto Stavros
Formato: tesis de grado
Fecha de Publicación:2009
Institución:Pontificia Universidad Católica del Perú
Repositorio:PUCP-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.pucp.edu.pe:20.500.14657/163598
Enlace del recurso:http://hdl.handle.net/20.500.12404/5070
Nivel de acceso:acceso abierto
Materia:Ingeniería biomédica--Aparatos e instrumentos
Lactantes.
Sistemas de control adaptativo
https://purl.org/pe-repo/ocde/ford#2.02.01
id RPUC_3356174e0635cf5bf35652dc9022c757
oai_identifier_str oai:repositorio.pucp.edu.pe:20.500.14657/163598
network_acronym_str RPUC
network_name_str PUCP-Institucional
repository_id_str 2905
dc.title.es_ES.fl_str_mv Diseño de un estimulador para generar la succión en recién nacidos prematuros
title Diseño de un estimulador para generar la succión en recién nacidos prematuros
spellingShingle Diseño de un estimulador para generar la succión en recién nacidos prematuros
Yika Tuesta, Alberto Stavros
Ingeniería biomédica--Aparatos e instrumentos
Lactantes.
Sistemas de control adaptativo
https://purl.org/pe-repo/ocde/ford#2.02.01
title_short Diseño de un estimulador para generar la succión en recién nacidos prematuros
title_full Diseño de un estimulador para generar la succión en recién nacidos prematuros
title_fullStr Diseño de un estimulador para generar la succión en recién nacidos prematuros
title_full_unstemmed Diseño de un estimulador para generar la succión en recién nacidos prematuros
title_sort Diseño de un estimulador para generar la succión en recién nacidos prematuros
author Yika Tuesta, Alberto Stavros
author_facet Yika Tuesta, Alberto Stavros
author_role author
dc.contributor.advisor.fl_str_mv Callupe Pérez, Rocío Liliana
dc.contributor.author.fl_str_mv Yika Tuesta, Alberto Stavros
dc.subject.es_ES.fl_str_mv Ingeniería biomédica--Aparatos e instrumentos
Lactantes.
Sistemas de control adaptativo
topic Ingeniería biomédica--Aparatos e instrumentos
Lactantes.
Sistemas de control adaptativo
https://purl.org/pe-repo/ocde/ford#2.02.01
dc.subject.ocde.es_ES.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.01
description This work raises a solution for the development of the sucking reflex in premature infants. This solution is based on a computer that uses a system of control of negative pressure applied directly in a pacifier common through a dock. In turn, this process is performed using a generator of waves that controls the frequency of suction as well as the kind of stimulation granted. The systems of stimulation of suction in preterm infants are presented as the solution, in the face of scarce stimulators of language, and the presence of latent problem. Currently, there are many researches [2] that have collaborated with the development process of the language, which would not only be measured patterns engines of non-nutritive sucking, but also produce a stimulator natural and harmless with the proper frequency response. The pacing system suction proposes stimulation based on control of a pneumatic motor and sensing constant on a variety of parameters, which provide an effective and natural exercise, for newborns in addition to cost reduction in the case of a treatment of short duration. Therefore, this thesis aims to design a stimulator system based on the generation of vacuum and inflated through a valve pneumatic, and sensing constant on a variety of parameters in order to stimulate the newborn premature to assist in the development of non-nutritive sucking, which directly affects their language . The main conclusion it should be mentioned that it is possible to obtain all the patterns engines of the suction non-nutritious to then use these in the construction of the signal generator of stimulation in the system that was developed in laboratory conditions. And it is important the contribution of this multidisciplinary work where unite two areas: neuroscience and electronics, resulting in initiating investigations in the field of the neurocognitive language disorder in children. [2]. FINAN, DS., BARLOW, SM., The actifier: a device for neurophysiological studies of orofacial control in human infants, Journal Speech Hear Research., vol. 39(4), pp. 833-8, Aug 1996.
publishDate 2009
dc.date.created.es_ES.fl_str_mv 2009
dc.date.accessioned.es_ES.fl_str_mv 2014-01-20T16:34:10Z
dc.date.available.es_ES.fl_str_mv 2014-01-20T16:34:10Z
dc.date.issued.fl_str_mv 2014-01-20
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/20.500.12404/5070
url http://hdl.handle.net/20.500.12404/5070
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.rights.es_ES.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_ES.fl_str_mv Pontificia Universidad Católica del Perú
dc.publisher.country.es_ES.fl_str_mv PE
dc.source.none.fl_str_mv reponame:PUCP-Institucional
instname:Pontificia Universidad Católica del Perú
instacron:PUCP
instname_str Pontificia Universidad Católica del Perú
instacron_str PUCP
institution PUCP
reponame_str PUCP-Institucional
collection PUCP-Institucional
repository.name.fl_str_mv Repositorio Institucional de la PUCP
repository.mail.fl_str_mv repositorio@pucp.pe
_version_ 1835639505626857472
spelling Callupe Pérez, Rocío LilianaYika Tuesta, Alberto Stavros2014-01-20T16:34:10Z2014-01-20T16:34:10Z20092014-01-20http://hdl.handle.net/20.500.12404/5070This work raises a solution for the development of the sucking reflex in premature infants. This solution is based on a computer that uses a system of control of negative pressure applied directly in a pacifier common through a dock. In turn, this process is performed using a generator of waves that controls the frequency of suction as well as the kind of stimulation granted. The systems of stimulation of suction in preterm infants are presented as the solution, in the face of scarce stimulators of language, and the presence of latent problem. Currently, there are many researches [2] that have collaborated with the development process of the language, which would not only be measured patterns engines of non-nutritive sucking, but also produce a stimulator natural and harmless with the proper frequency response. The pacing system suction proposes stimulation based on control of a pneumatic motor and sensing constant on a variety of parameters, which provide an effective and natural exercise, for newborns in addition to cost reduction in the case of a treatment of short duration. Therefore, this thesis aims to design a stimulator system based on the generation of vacuum and inflated through a valve pneumatic, and sensing constant on a variety of parameters in order to stimulate the newborn premature to assist in the development of non-nutritive sucking, which directly affects their language . The main conclusion it should be mentioned that it is possible to obtain all the patterns engines of the suction non-nutritious to then use these in the construction of the signal generator of stimulation in the system that was developed in laboratory conditions. And it is important the contribution of this multidisciplinary work where unite two areas: neuroscience and electronics, resulting in initiating investigations in the field of the neurocognitive language disorder in children. [2]. FINAN, DS., BARLOW, SM., The actifier: a device for neurophysiological studies of orofacial control in human infants, Journal Speech Hear Research., vol. 39(4), pp. 833-8, Aug 1996.El presente trabajo plantea una solución para el desarrollo del reflejo de succión en recién nacidos prematuros. Dicha solución está basada en un equipo que usa un sistema de control de presión negativa aplicada directamente en un chupón común mediante un acople. A su vez, este proceso se realiza usando un generador de ondas que controla la frecuencia de succión así como el tipo de estimulación otorgada. Los sistemas de estimulación de succión en recién nacidos prematuros se presentan como la solución, ante la escasez de estimuladores del lenguaje, y la presencia latente del problema. Actualmente, existen muchos trabajos de investigación [2] que han colaborado con el proceso desarrollo del lenguaje, lo cual no solo mediría los patrones motores de la succión no nutritiva, sino también producir un estimulador natural e inocuo con una apropiada frecuencia de respuesta. El sistema de estimulación de succión propone una estimulación basada en el control de un motor neumático y el sensado constante de diversos parámetros, los cuales proveen un eficaz y natural ejercicio, para los recién nacidos además reducción de costos al tratarse de un tratamiento de corta duración. Por lo tanto, este trabajo de tesis tiene como objetivo diseñar un sistema estimulador basado en la generación de vacío e inflado mediante una válvula neumática, y el sensado constante de diversos parámetros con la finalidad de estimular al recién nacido prematuro para ayudar en el desarrollo de la succión no nutritiva, la cual afecta directamente su lenguaje. Como conclusión principal se debe mencionar que es posible obtener los patrones motores de la succión no-nutritiva para luego usar estos en la construcción de la señal generadora de estimulación en el sistema desarrollado en condiciones de laboratorio. Y es importante el aporte de este trabajo multidisciplinario donde se unen dos áreas: neurociencias y electrónica, dando como resultado iniciar investigaciones en el campo neurocognitivo del trastorno del lenguaje en el niño.spaPontificia Universidad Católica del PerúPEinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Ingeniería biomédica--Aparatos e instrumentosLactantes.Sistemas de control adaptativohttps://purl.org/pe-repo/ocde/ford#2.02.01Diseño de un estimulador para generar la succión en recién nacidos prematurosinfo:eu-repo/semantics/bachelorThesisreponame:PUCP-Institucionalinstname:Pontificia Universidad Católica del Perúinstacron:PUCPIngeniero ElectrónicoTítulo ProfesionalPontificia Universidad Católica del Perú. Facultad de Ciencias e IngenieríaIngeniería Electrónica09534729https://orcid.org/0000-0001-5814-3926712026https://purl.org/pe-repo/renati/level#tituloProfesionalhttps://purl.org/pe-repo/renati/type#tesis20.500.14657/163598oai:repositorio.pucp.edu.pe:20.500.14657/1635982025-02-13 11:16:18.853http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessmetadata.onlyhttps://repositorio.pucp.edu.peRepositorio Institucional de la PUCPrepositorio@pucp.pe
score 13.873297
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).