Objectives: The purpose of the present study was to determine and compare the surface microhardness of three brands of artificial molars to verify if there is a significant difference between them. Materials and Methods: artificial molars were used based on acrylic resin, 15 lower molars of each bra...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2018 |
| Institución: | Universidad de San Martín de Porres |
| Repositorio: | Revistas - Universidad de San Martín de Porres |
| Lenguaje: | español |
| OAI Identifier: | oai:revistas.usmp.edu.pe:article/1320 |
| Enlace del recurso: | https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320 |
| Nivel de acceso: | acceso abierto |
| Materia: | Jaw Edentulous Tooth Artificial Hardness Tests Arcada edéntula Diente artificial Pruebas de dureza. |
| id |
REVUSMP_beb844f1c0916b6d56e0c9bec5d60aa6 |
|---|---|
| oai_identifier_str |
oai:revistas.usmp.edu.pe:article/1320 |
| network_acronym_str |
REVUSMP |
| network_name_str |
Revistas - Universidad de San Martín de Porres |
| repository_id_str |
|
| spelling |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studioMicrodureza superficial de molares artificiales de resina acrílica utilizados en odontología rehabilitadora, tres marcas comerciales. Estudio in-vitro.Cruz Gallegos, PaulCruz Gallegos, AlexanderSantillán Cruz, Vinicio Santillán CruzJawEdentulousToothArtificialHardness TestsArcada edéntulaDiente artificialPruebas de dureza.Objectives: The purpose of the present study was to determine and compare the surface microhardness of three brands of artificial molars to verify if there is a significant difference between them. Materials and Methods: artificial molars were used based on acrylic resin, 15 lower molars of each brand TRILUX®, Gnathostar® and Duratone-n®, the samples were prepared making a coronal cross section to obtain a flat, smooth surface and polished, it was placed in pvc dies with 1.5cm Autopolymerizable acrylic, the surface to be analyzed was dyed blue, to then be taken to the Duroline-M Metkon Microdurometer where 3 indentations were made for each sample with a force of 200 grams during 15 seconds obtaining the results in units of Vickers (Hv). Results: The TRILUX® brand molars had higher surface microhardness with an average of 24,306 ± 1.41Hv, followed by the morals Duratone-n® with 22.21 ± 0.72 Hv and finally Gnathostar® with 19.82 ± 0.66 Hv, by statistical tests. He was able to confirm thaObjetivo: El propósito del presente estudio fue determinar y comparar la microdureza superficial de tres marcas de molares artificiales para comprobar si existe diferencia significativa entre las mismas. Materiales y Métodos: Se utilizó molares artificiales a base de resina acrílica,15 molares inferiores de cada marca TRILUX®, Gnathostar ® y Duratone -n®. Se preparó las muestras realizando un corte transversal a nivel coronal para obtener una superficie plana, lisa y pulida. Se colocaron e n troqueles de tubo PVC con acrílico autopolimerizable de 1,5 cm. Se tinturó la superficie a analizar de color azul , para luego llevar al microdurómetro Metkon Duroline-M donde se realizó 3 indentaciones por cada muestra con una fuerza de 200 gramos durante 15 segundos, obteniendo los resultados en unidades de Vickers (Hv). Resultados: Los molares de la marca TRILUX® presentaron mayor microdureza superficial con un promedio de 24.306 ±1.41Hv, seguidos de los morales Duratone-n® con22.21 ±0.Universidad de San Martín de Porres, Facultad de Odontología.2018-06-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/xmlhttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320KIRU ; Vol. 15 No. 2 (2018): Kiru (Abril - Junio) KIRU ISSN electrónico 2410-2717 ISSN Impreso 1812 - 7886; Vol. 15 Núm. 2 (2018): Kiru (Abril - Junio)2410-27171812-7886reponame:Revistas - Universidad de San Martín de Porresinstname:Universidad de San Martín de Porresinstacron:USMPspahttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320/1065https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320/MICRODUREZA%20SUPERFICIAL%20DE%20MOLARES%20ARTIFICIALES%20DE%20RESINA%20ACR%C3%8DLICA%20UTILIZADOS%20EN%20ODONTOLOG%C3%8DA%20REHABILITADORA%2C%20TRES%20MARCAS%20COMERCIALES.%20ESTUDIO%20IN-VITRODerechos de autor 2018 KIRU Revista de la Facultad de Odontología - Universidad de San Martín de Porresinfo:eu-repo/semantics/openAccessoai:revistas.usmp.edu.pe:article/13202019-06-07T17:21:35Z |
| dc.title.none.fl_str_mv |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio Microdureza superficial de molares artificiales de resina acrílica utilizados en odontología rehabilitadora, tres marcas comerciales. Estudio in-vitro. |
| title |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| spellingShingle |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio Cruz Gallegos, Paul Jaw Edentulous Tooth Artificial Hardness Tests Arcada edéntula Diente artificial Pruebas de dureza. |
| title_short |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| title_full |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| title_fullStr |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| title_full_unstemmed |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| title_sort |
Superficial micro-strength of artificial mills of acrylic resin used in rehabilitating dentistry, three trade marks. In-vitro studio |
| dc.creator.none.fl_str_mv |
Cruz Gallegos, Paul Cruz Gallegos, Alexander Santillán Cruz, Vinicio Santillán Cruz |
| author |
Cruz Gallegos, Paul |
| author_facet |
Cruz Gallegos, Paul Cruz Gallegos, Alexander Santillán Cruz, Vinicio Santillán Cruz |
| author_role |
author |
| author2 |
Cruz Gallegos, Alexander Santillán Cruz, Vinicio Santillán Cruz |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Jaw Edentulous Tooth Artificial Hardness Tests Arcada edéntula Diente artificial Pruebas de dureza. |
| topic |
Jaw Edentulous Tooth Artificial Hardness Tests Arcada edéntula Diente artificial Pruebas de dureza. |
| description |
Objectives: The purpose of the present study was to determine and compare the surface microhardness of three brands of artificial molars to verify if there is a significant difference between them. Materials and Methods: artificial molars were used based on acrylic resin, 15 lower molars of each brand TRILUX®, Gnathostar® and Duratone-n®, the samples were prepared making a coronal cross section to obtain a flat, smooth surface and polished, it was placed in pvc dies with 1.5cm Autopolymerizable acrylic, the surface to be analyzed was dyed blue, to then be taken to the Duroline-M Metkon Microdurometer where 3 indentations were made for each sample with a force of 200 grams during 15 seconds obtaining the results in units of Vickers (Hv). Results: The TRILUX® brand molars had higher surface microhardness with an average of 24,306 ± 1.41Hv, followed by the morals Duratone-n® with 22.21 ± 0.72 Hv and finally Gnathostar® with 19.82 ± 0.66 Hv, by statistical tests. He was able to confirm tha |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-06-30 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320 |
| url |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320/1065 https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1320/MICRODUREZA%20SUPERFICIAL%20DE%20MOLARES%20ARTIFICIALES%20DE%20RESINA%20ACR%C3%8DLICA%20UTILIZADOS%20EN%20ODONTOLOG%C3%8DA%20REHABILITADORA%2C%20TRES%20MARCAS%20COMERCIALES.%20ESTUDIO%20IN-VITRO |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/xml |
| dc.publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
| publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
| dc.source.none.fl_str_mv |
KIRU ; Vol. 15 No. 2 (2018): Kiru (Abril - Junio) KIRU ISSN electrónico 2410-2717 ISSN Impreso 1812 - 7886; Vol. 15 Núm. 2 (2018): Kiru (Abril - Junio) 2410-2717 1812-7886 reponame:Revistas - Universidad de San Martín de Porres instname:Universidad de San Martín de Porres instacron:USMP |
| instname_str |
Universidad de San Martín de Porres |
| instacron_str |
USMP |
| institution |
USMP |
| reponame_str |
Revistas - Universidad de San Martín de Porres |
| collection |
Revistas - Universidad de San Martín de Porres |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1847517300317487104 |
| score |
12.67775 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).