Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report
Descripción del Articulo
Cone Beam Computed Tomography offers highly precise 3D images ideal for diagnosis and case planning, although this imaging method involves the use of high doses of radiation. When considering the optimization principle, radiation dose reduction methods aim to modify the technical parameters of the e...
Autores: | , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2024 |
Institución: | Universidad de San Martín de Porres |
Repositorio: | Revistas - Universidad de San Martín de Porres |
Lenguaje: | español |
OAI Identifier: | oai:revistas.usmp.edu.pe:article/2771 |
Enlace del recurso: | https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771 |
Nivel de acceso: | acceso abierto |
Materia: | Tomography, Radiation Dose, Child, Impacted Tooth Tomografía; Dosis de radiación; Niño; Diente retenido |
id |
REVUSMP_9c2c993bf266a981d9d68da52d7f47e4 |
---|---|
oai_identifier_str |
oai:revistas.usmp.edu.pe:article/2771 |
network_acronym_str |
REVUSMP |
network_name_str |
Revistas - Universidad de San Martín de Porres |
repository_id_str |
|
spelling |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case reportTomografía computarizada de haz cónico con protocolo de baja dosis para la localización de caninos retenidos en paciente pediátrico. Reporte de casoMartínez Gómez, Juan Carlos Jiménez-Pinto, HumbertoSalazar Gómez, Oliangel del ValleOrtega-Pertuz , Ana IsabelQuevedo Piña, MairaTomography, Radiation Dose, Child, Impacted ToothTomografía; Dosis de radiación; Niño; Diente retenidoCone Beam Computed Tomography offers highly precise 3D images ideal for diagnosis and case planning, although this imaging method involves the use of high doses of radiation. When considering the optimization principle, radiation dose reduction methods aim to modify the technical parameters of the equipment to obtain an ideal combination between dose and image quality. This is important in the pediatric patient because the highest levels of risk are associated with X-ray exposure in this age group. We present the case of an 11-year-old female patient is presented, in which a low-resolution protocol is used to locate the maxillary retained canines. The advantages and practical application of this imaging study method are analyzed by performing variations in exposure parameters. Supported by tomographic images, the surgical procedure is carried out to subsequently a guided eruption, achieving the location of the canines in their usual position. It is evident that the adjustment of the exposure parameters did not affect the required image and the expected results were achieved.La tomografía computarizada de haz cónico ofrece imágenes en los tres planos del espacio (3D) con alta precisión ideales para el diagnóstico y planificación de casos, aunque este método imagenológico implica el uso de mayores dosis de radiación. Considerando el principio de optimización, los métodos de reducción de la dosis de radiación tienen como objetivo modificar los parámetros técnicos del equipo para obtener una combinación ideal entre dosis y calidad de imagen. Esto es importante en el paciente pediátrico debido a que los niveles más altos de riesgo, debido a los efectos adversos asociados con la exposición a los rayos X en este grupo de edad. Objetivo: se presenta el caso de una paciente sexo femenino de 11 años de edad, en el cual se utiliza un protocolo de baja resolución para la localización de los caninos retenidos maxilares. Se analizan las ventajas y la aplicación práctica de este método de estudio por imágenes realizando variaciones en los parámetros de exposición. Apoyado en las imágenes tomográficas se realiza el procedimiento quirúrgico para posteriormente realizar erupción guiada, logrando la ubicación de los caninos en su posición habitual. Se evidencia que el ajuste de los parámetros de exposición no afectó la imagen requerida y se lograron los resultados esperados.Universidad de San Martín de Porres, Facultad de Odontología.2024-01-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/xmlhttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/277110.24265/kiru.2024.v21n1.02KIRU ; Vol. 21 No. 1 (2024): KIRU (ENE-MAR); 12-20 KIRU ISSN (Impreso): 1812 - 7886 ISSN (Digital): 2410-2717; Vol. 21 Núm. 1 (2024): KIRU (ENE-MAR); 12-202410-27171812-7886reponame:Revistas - Universidad de San Martín de Porresinstname:Universidad de San Martín de Porresinstacron:USMPspahttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771/3804https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771/3805Derechos de autor 2024 Juan Carlos Martínez Gómez, Humberto Jiménez-Pinto, Oliangel del Valle Salazar Gómez, Ana Isabel Ortega-Pertuz , Maira Quevedo Piñahttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:revistas.usmp.edu.pe:article/27712025-03-06T15:36:24Z |
dc.title.none.fl_str_mv |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report Tomografía computarizada de haz cónico con protocolo de baja dosis para la localización de caninos retenidos en paciente pediátrico. Reporte de caso |
title |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
spellingShingle |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report Martínez Gómez, Juan Carlos Tomography, Radiation Dose, Child, Impacted Tooth Tomografía; Dosis de radiación; Niño; Diente retenido |
title_short |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
title_full |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
title_fullStr |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
title_full_unstemmed |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
title_sort |
Cone beam computed tomography with low dose protocol for the location of impacted canines in pediatric patients. Case report |
dc.creator.none.fl_str_mv |
Martínez Gómez, Juan Carlos Jiménez-Pinto, Humberto Salazar Gómez, Oliangel del Valle Ortega-Pertuz , Ana Isabel Quevedo Piña, Maira |
author |
Martínez Gómez, Juan Carlos |
author_facet |
Martínez Gómez, Juan Carlos Jiménez-Pinto, Humberto Salazar Gómez, Oliangel del Valle Ortega-Pertuz , Ana Isabel Quevedo Piña, Maira |
author_role |
author |
author2 |
Jiménez-Pinto, Humberto Salazar Gómez, Oliangel del Valle Ortega-Pertuz , Ana Isabel Quevedo Piña, Maira |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Tomography, Radiation Dose, Child, Impacted Tooth Tomografía; Dosis de radiación; Niño; Diente retenido |
topic |
Tomography, Radiation Dose, Child, Impacted Tooth Tomografía; Dosis de radiación; Niño; Diente retenido |
description |
Cone Beam Computed Tomography offers highly precise 3D images ideal for diagnosis and case planning, although this imaging method involves the use of high doses of radiation. When considering the optimization principle, radiation dose reduction methods aim to modify the technical parameters of the equipment to obtain an ideal combination between dose and image quality. This is important in the pediatric patient because the highest levels of risk are associated with X-ray exposure in this age group. We present the case of an 11-year-old female patient is presented, in which a low-resolution protocol is used to locate the maxillary retained canines. The advantages and practical application of this imaging study method are analyzed by performing variations in exposure parameters. Supported by tomographic images, the surgical procedure is carried out to subsequently a guided eruption, achieving the location of the canines in their usual position. It is evident that the adjustment of the exposure parameters did not affect the required image and the expected results were achieved. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-01-31 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771 10.24265/kiru.2024.v21n1.02 |
url |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771 |
identifier_str_mv |
10.24265/kiru.2024.v21n1.02 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771/3804 https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/2771/3805 |
dc.rights.none.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf text/xml |
dc.publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
dc.source.none.fl_str_mv |
KIRU ; Vol. 21 No. 1 (2024): KIRU (ENE-MAR); 12-20 KIRU ISSN (Impreso): 1812 - 7886 ISSN (Digital): 2410-2717; Vol. 21 Núm. 1 (2024): KIRU (ENE-MAR); 12-20 2410-2717 1812-7886 reponame:Revistas - Universidad de San Martín de Porres instname:Universidad de San Martín de Porres instacron:USMP |
instname_str |
Universidad de San Martín de Porres |
instacron_str |
USMP |
institution |
USMP |
reponame_str |
Revistas - Universidad de San Martín de Porres |
collection |
Revistas - Universidad de San Martín de Porres |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1843712219794112512 |
score |
12.656004 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).