Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna
Descripción del Articulo
In the Tacna region, buildings close to the sea often present pathologies in the concrete elements. These pathologies over time generate the development of the deterioration of the same concrete affecting the durability and service life of the buildings. The research aims to provide technical expert...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad Privada de Tacna |
Repositorio: | Revistas - Universidad Privada de Tacna |
Lenguaje: | español |
OAI Identifier: | oai:revistas.upt.edu.pe:article/418 |
Enlace del recurso: | https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/418 |
Nivel de acceso: | acceso abierto |
Materia: | Patología concreto ambiente marino Pathology concrete marine environment |
id |
REVUPT_753f3331ffd9020386314722dd96854a |
---|---|
oai_identifier_str |
oai:revistas.upt.edu.pe:article/418 |
network_acronym_str |
REVUPT |
network_name_str |
Revistas - Universidad Privada de Tacna |
repository_id_str |
|
dc.title.none.fl_str_mv |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna Evaluación y diagnóstico de elementos de concreto localizados en ambiente marino del distrito de Ite, Tacna |
title |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
spellingShingle |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna Laguna Chite, Milagros Natali Patología concreto ambiente marino Pathology concrete marine environment |
title_short |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
title_full |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
title_fullStr |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
title_full_unstemmed |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
title_sort |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, Tacna |
dc.creator.none.fl_str_mv |
Laguna Chite, Milagros Natali Mamani Antipuerta, Alonso Dorian Cruz Espinoza, Cesar |
author |
Laguna Chite, Milagros Natali |
author_facet |
Laguna Chite, Milagros Natali Mamani Antipuerta, Alonso Dorian Cruz Espinoza, Cesar |
author_role |
author |
author2 |
Mamani Antipuerta, Alonso Dorian Cruz Espinoza, Cesar |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Patología concreto ambiente marino Pathology concrete marine environment |
topic |
Patología concreto ambiente marino Pathology concrete marine environment |
description |
In the Tacna region, buildings close to the sea often present pathologies in the concrete elements. These pathologies over time generate the development of the deterioration of the same concrete affecting the durability and service life of the buildings. The research aims to provide technical expertise in the stages of the start, planning and execution of buildings considering the vulnerability linked to a marine environment; by evaluating the mechanical, physical and chemical properties of concrete, diagnosing pathologies and concluding with a repair proposal. The research site corresponds to the Municipal Recreation Complex "Los Humedales de Ite", considering that it is exposed to a marine environment and a distance to the sea less than 2 km. Preliminary and detailed inspection was used for the development of research. Preliminary inspection identified exposure conditions (weather characteristics), and detailed inspection determined concrete properties through laboratory testing. The results were evaluated by considering the standards of the ACI, NTP, ASTM and ASOCRETO standards; it is concluded that the quality of the concrete is poor for a severe marine atmosphere because the transport of harmful agents occurs through the porosity and absorption of the concrete. The physicochemical characteristics of the materials indicated that the contaminated ingredient is the fine aggregate due to its high chloride index, a factor that adds up to the corrosion process of the reinforcing steel. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-12-24 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/418 10.47796/ing.v2i2.418 |
url |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/418 |
identifier_str_mv |
10.47796/ing.v2i2.418 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/418/353 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UNIVERSIDAD PRIVADA DE TACNA |
publisher.none.fl_str_mv |
UNIVERSIDAD PRIVADA DE TACNA |
dc.source.none.fl_str_mv |
INGENIERÍA INVESTIGA; Vol. 2 No. 2 (2020): Ingeniería Investiga; 453 - 474 INGENIERÍA INVESTIGA; Vol. 2 Núm. 2 (2020): Ingeniería Investiga; 453 - 474 2708-3039 10.47796/ing.v2i2 reponame:Revistas - Universidad Privada de Tacna instname:Universidad Privada de Tacna instacron:UPT |
instname_str |
Universidad Privada de Tacna |
instacron_str |
UPT |
institution |
UPT |
reponame_str |
Revistas - Universidad Privada de Tacna |
collection |
Revistas - Universidad Privada de Tacna |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1846157689335316480 |
spelling |
Evaluation and diagnostic of concrete elements localized in marino environment of the Ite district, TacnaEvaluación y diagnóstico de elementos de concreto localizados en ambiente marino del distrito de Ite, TacnaLaguna Chite, Milagros NataliMamani Antipuerta, Alonso DorianCruz Espinoza, CesarPatologíaconcretoambiente marinoPathologyconcretemarine environmentIn the Tacna region, buildings close to the sea often present pathologies in the concrete elements. These pathologies over time generate the development of the deterioration of the same concrete affecting the durability and service life of the buildings. The research aims to provide technical expertise in the stages of the start, planning and execution of buildings considering the vulnerability linked to a marine environment; by evaluating the mechanical, physical and chemical properties of concrete, diagnosing pathologies and concluding with a repair proposal. The research site corresponds to the Municipal Recreation Complex "Los Humedales de Ite", considering that it is exposed to a marine environment and a distance to the sea less than 2 km. Preliminary and detailed inspection was used for the development of research. Preliminary inspection identified exposure conditions (weather characteristics), and detailed inspection determined concrete properties through laboratory testing. The results were evaluated by considering the standards of the ACI, NTP, ASTM and ASOCRETO standards; it is concluded that the quality of the concrete is poor for a severe marine atmosphere because the transport of harmful agents occurs through the porosity and absorption of the concrete. The physicochemical characteristics of the materials indicated that the contaminated ingredient is the fine aggregate due to its high chloride index, a factor that adds up to the corrosion process of the reinforcing steel.En la región de Tacna, las edificaciones con cercanía al mar frecuentemente presentan patologías en los elementos de concreto. Estas patologías con el tiempo generan el desarrollo del deterioro del mismo concreto afectando la durabilidad y el tiempo de vida útil de las edificaciones. La investigación tiene la finalidad de aportar conocimientos técnicos en las etapas de inicio, planificación y ejecución de edificaciones considerando la vulnerabilidad vinculada a un ambiente marino; mediante la evaluación de las propiedades mecánicas, físicas y químicas del concreto, diagnóstico de patologías y concluyendo con una propuesta de reparación. El lugar de investigación corresponde al Complejo Recreacional Municipal “Los Humedales de Ite”, considerando que está expuesto a un ambiente marino y a una distancia al mar menor de 2 km. Para el desarrollo de la investigación se empleó la inspección preliminar y detallada. La inspección preliminar identificó las condiciones de exposición (características meteorológicas), y la inspección detallada determinó las propiedades del concreto mediante los ensayos de laboratorio. Los resultados se evaluaron considerando los estándares de las normas ACI, NTP, ASTM y ASOCRETO; concluyéndose que la calidad del concreto es deficiente para una atmósfera marina severa debido a que el transporte de agentes nocivos se da través de la porosidad y absorción del concreto. Las características fisicoquímicas de los materiales indicaron que el ingrediente contaminado es el agregado fino debido a su alto índice de cloruros, factor que suma el proceso de corrosión del acero de refuerzoUNIVERSIDAD PRIVADA DE TACNA2020-12-24info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/41810.47796/ing.v2i2.418INGENIERÍA INVESTIGA; Vol. 2 No. 2 (2020): Ingeniería Investiga; 453 - 474INGENIERÍA INVESTIGA; Vol. 2 Núm. 2 (2020): Ingeniería Investiga; 453 - 4742708-303910.47796/ing.v2i2reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/418/353info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/4182021-11-29T10:30:25Z |
score |
12.884314 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).