Evaluation of green wall in the decrease of noise and its environmental perception in an educational center
Descripción del Articulo
The study aimed to install a green wall in order to carry out a comparative analysis of the levels of noise reduction, as well as to evaluate the environmental perception; the study was carried out in the city of Tacna in the facilities of the educational institution Verdad y Vida - Veritas et Vita....
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad Privada de Tacna |
Repositorio: | Revistas - Universidad Privada de Tacna |
Lenguaje: | español |
OAI Identifier: | oai:revistas.upt.edu.pe:article/294 |
Enlace del recurso: | https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/294 |
Nivel de acceso: | acceso abierto |
Materia: | Calidad ambiental Muro verde Percepción ambiental Ruido Environmental quality Green wall Environmental perception Noise |
id |
REVUPT_52fe77c1e2e49ab31e547d1ab0b57761 |
---|---|
oai_identifier_str |
oai:revistas.upt.edu.pe:article/294 |
network_acronym_str |
REVUPT |
network_name_str |
Revistas - Universidad Privada de Tacna |
repository_id_str |
|
spelling |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational centerEvaluación de muro verde en la disminución de ruido y su percepción ambiental en un centro educativoZeballos Pimentel, Ana ClaudiaRomán Arce, Carmen RosaCalidad ambientalMuro verdePercepción ambientalRuidoEnvironmental qualityGreen wallEnvironmental perceptionNoiseThe study aimed to install a green wall in order to carry out a comparative analysis of the levels of noise reduction, as well as to evaluate the environmental perception; the study was carried out in the city of Tacna in the facilities of the educational institution Verdad y Vida - Veritas et Vita. For the construction of the green wall, the Aptenia cordifolia that was installed outside the educational center was used. In order to noise reduction monitoring, two monitoring points were located; one in the direction of the noise source and the other behind the green wall where the noise is directed. Monitoring was carried out at night and daytime, resulting in a reduction in daytime of 2,593 ± 0.47 and at night of 5.38 ± 0.19 in both cases significant (p-value -0.05). The environmental perception evaluated by the student population indicates that 50% perceive that green walls reduce noise. It is concluded that green walls can reduce noise and that they could serve as an acoustic screen, with Aptenia cordifolia being a good alternative.El estudio tuvo como objetivo instalar un muro verde con la finalidad de realizar un análisis comparativo de los niveles de disminución de ruido, así como evaluar la percepción ambiental El estudio fue realizado en la ciudad de Tacna en las instalaciones de institución educativa Verdad y Vida – Veritas et Vita. Para la construcción del muro verde se empleó la Aptenia cordifolia que fue instalada en los exteriores del centro educativo, para evaluar reducción de ruido se ubicó dos puntos de monitoreo; uno en dirección de la fuente de ruido y el otro detrás del muro verde hacia donde se dirige el ruido.UNIVERSIDAD PRIVADA DE TACNA2020-07-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/29410.47796/ing.v2i01.294INGENIERÍA INVESTIGA; Vol. 2 No. 01 (2020): Ingeniería Investiga; pp. 246 - 253INGENIERÍA INVESTIGA; Vol. 2 Núm. 01 (2020): Ingeniería Investiga; pp. 246 - 2532708-303910.47796/ing.v2i01reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/294/265info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/2942021-11-29T10:39:09Z |
dc.title.none.fl_str_mv |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center Evaluación de muro verde en la disminución de ruido y su percepción ambiental en un centro educativo |
title |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
spellingShingle |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center Zeballos Pimentel, Ana Claudia Calidad ambiental Muro verde Percepción ambiental Ruido Environmental quality Green wall Environmental perception Noise |
title_short |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
title_full |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
title_fullStr |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
title_full_unstemmed |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
title_sort |
Evaluation of green wall in the decrease of noise and its environmental perception in an educational center |
dc.creator.none.fl_str_mv |
Zeballos Pimentel, Ana Claudia Román Arce, Carmen Rosa |
author |
Zeballos Pimentel, Ana Claudia |
author_facet |
Zeballos Pimentel, Ana Claudia Román Arce, Carmen Rosa |
author_role |
author |
author2 |
Román Arce, Carmen Rosa |
author2_role |
author |
dc.subject.none.fl_str_mv |
Calidad ambiental Muro verde Percepción ambiental Ruido Environmental quality Green wall Environmental perception Noise |
topic |
Calidad ambiental Muro verde Percepción ambiental Ruido Environmental quality Green wall Environmental perception Noise |
description |
The study aimed to install a green wall in order to carry out a comparative analysis of the levels of noise reduction, as well as to evaluate the environmental perception; the study was carried out in the city of Tacna in the facilities of the educational institution Verdad y Vida - Veritas et Vita. For the construction of the green wall, the Aptenia cordifolia that was installed outside the educational center was used. In order to noise reduction monitoring, two monitoring points were located; one in the direction of the noise source and the other behind the green wall where the noise is directed. Monitoring was carried out at night and daytime, resulting in a reduction in daytime of 2,593 ± 0.47 and at night of 5.38 ± 0.19 in both cases significant (p-value -0.05). The environmental perception evaluated by the student population indicates that 50% perceive that green walls reduce noise. It is concluded that green walls can reduce noise and that they could serve as an acoustic screen, with Aptenia cordifolia being a good alternative. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-07-14 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/294 10.47796/ing.v2i01.294 |
url |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/294 |
identifier_str_mv |
10.47796/ing.v2i01.294 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/ingenieria/article/view/294/265 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
UNIVERSIDAD PRIVADA DE TACNA |
publisher.none.fl_str_mv |
UNIVERSIDAD PRIVADA DE TACNA |
dc.source.none.fl_str_mv |
INGENIERÍA INVESTIGA; Vol. 2 No. 01 (2020): Ingeniería Investiga; pp. 246 - 253 INGENIERÍA INVESTIGA; Vol. 2 Núm. 01 (2020): Ingeniería Investiga; pp. 246 - 253 2708-3039 10.47796/ing.v2i01 reponame:Revistas - Universidad Privada de Tacna instname:Universidad Privada de Tacna instacron:UPT |
instname_str |
Universidad Privada de Tacna |
instacron_str |
UPT |
institution |
UPT |
reponame_str |
Revistas - Universidad Privada de Tacna |
collection |
Revistas - Universidad Privada de Tacna |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1844889327561080832 |
score |
12.636287 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).