Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs
Descripción del Articulo
This study aimed to determine possible significant variations in awake dogs in blood pressure between the four limbs, including the tail. The diastolic, systolic, and mean arterial pressures were taken using the SunTech Medical® equipment, using the oscillometry technique, in each of the limbs and t...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2018 |
| Institución: | Universidad Nacional Mayor de San Marcos |
| Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
| Lenguaje: | español |
| OAI Identifier: | oai:revistasinvestigacion.unmsm.edu.pe:article/15194 |
| Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194 |
| Nivel de acceso: | acceso abierto |
| Materia: | presión arterial diastólica presión arterial sistólica presión arterial media presión arterial indirecta oscilometría diastolic blood pressure systolic blood pressure mean blood pressure non-invasive blood pressure oscillometry |
| id |
REVUNMSM_f6de9ea572ce33e49af29ce99a107c2d |
|---|---|
| oai_identifier_str |
oai:revistasinvestigacion.unmsm.edu.pe:article/15194 |
| network_acronym_str |
REVUNMSM |
| network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository_id_str |
|
| spelling |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogsComparación de valores de presión arterial indirecta medida en cinco puntos anatómicos en caninos despiertosJiménez-Ballén, ValentinaVargas-Pinto, Pedropresión arterial diastólicapresión arterial sistólicapresión arterial mediapresión arterial indirectaoscilometríadiastolic blood pressuresystolic blood pressuremean blood pressurenon-invasive blood pressureoscillometryThis study aimed to determine possible significant variations in awake dogs in blood pressure between the four limbs, including the tail. The diastolic, systolic, and mean arterial pressures were taken using the SunTech Medical® equipment, using the oscillometry technique, in each of the limbs and the tail of 17 canine patients in a pet clinic in Bogotá, Colombia. No significant differences were found between the diastolic, systolic, and mean blood pressure values between each of the limbs and the tail.En el presente estudio se buscó determinar si existe una variación significativa en perros despiertos entre la presión arterial entre los cuatro miembros, incluyendo la cola. Las presiones arteriales diastólica, sistólica y media fueron tomadas, utilizando el equipo SunTech Medical®, mediante la técnica de oscilometría, en cada uno de los miembros y la cola de 17 caninos pacientes de una clínica de pequeños animales en Bogotá, Colombia. No se encontró diferencias significativas entre los valores de la presión arterial diastólica, sistólica y media entre cada uno de los miembros y la cola.Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria2018-11-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttps://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/1519410.15381/rivep.v29i4.15194Revista de Investigaciones Veterinarias del Perú; Vol. 29 No. 4 (2018); 1156-1160Revista de Investigaciones Veterinarias del Perú; Vol. 29 Núm. 4 (2018); 1156-11601682-34191609-9117reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194/13284https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194/13807Derechos de autor 2018 Valentina Jiménez-Ballén, Pedro Vargas-Pintohttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:revistasinvestigacion.unmsm.edu.pe:article/151942018-11-26T18:06:04Z |
| dc.title.none.fl_str_mv |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs Comparación de valores de presión arterial indirecta medida en cinco puntos anatómicos en caninos despiertos |
| title |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| spellingShingle |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs Jiménez-Ballén, Valentina presión arterial diastólica presión arterial sistólica presión arterial media presión arterial indirecta oscilometría diastolic blood pressure systolic blood pressure mean blood pressure non-invasive blood pressure oscillometry |
| title_short |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| title_full |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| title_fullStr |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| title_full_unstemmed |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| title_sort |
Comparison of indirect arterial blood pressure values measured in five anatomical sites in awake dogs |
| dc.creator.none.fl_str_mv |
Jiménez-Ballén, Valentina Vargas-Pinto, Pedro |
| author |
Jiménez-Ballén, Valentina |
| author_facet |
Jiménez-Ballén, Valentina Vargas-Pinto, Pedro |
| author_role |
author |
| author2 |
Vargas-Pinto, Pedro |
| author2_role |
author |
| dc.subject.none.fl_str_mv |
presión arterial diastólica presión arterial sistólica presión arterial media presión arterial indirecta oscilometría diastolic blood pressure systolic blood pressure mean blood pressure non-invasive blood pressure oscillometry |
| topic |
presión arterial diastólica presión arterial sistólica presión arterial media presión arterial indirecta oscilometría diastolic blood pressure systolic blood pressure mean blood pressure non-invasive blood pressure oscillometry |
| description |
This study aimed to determine possible significant variations in awake dogs in blood pressure between the four limbs, including the tail. The diastolic, systolic, and mean arterial pressures were taken using the SunTech Medical® equipment, using the oscillometry technique, in each of the limbs and the tail of 17 canine patients in a pet clinic in Bogotá, Colombia. No significant differences were found between the diastolic, systolic, and mean blood pressure values between each of the limbs and the tail. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-11-25 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194 10.15381/rivep.v29i4.15194 |
| url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194 |
| identifier_str_mv |
10.15381/rivep.v29i4.15194 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194/13284 https://revistasinvestigacion.unmsm.edu.pe/index.php/veterinaria/article/view/15194/13807 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2018 Valentina Jiménez-Ballén, Pedro Vargas-Pinto https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2018 Valentina Jiménez-Ballén, Pedro Vargas-Pinto https://creativecommons.org/licenses/by-nc-sa/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf text/html |
| dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria |
| publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Medicina Veterinaria |
| dc.source.none.fl_str_mv |
Revista de Investigaciones Veterinarias del Perú; Vol. 29 No. 4 (2018); 1156-1160 Revista de Investigaciones Veterinarias del Perú; Vol. 29 Núm. 4 (2018); 1156-1160 1682-3419 1609-9117 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
| instname_str |
Universidad Nacional Mayor de San Marcos |
| instacron_str |
UNMSM |
| institution |
UNMSM |
| reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| collection |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1848424241134829568 |
| score |
13.921002 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).