Cardiotocography Properties Mothers with Pregnancy Induced Hypertension

Descripción del Articulo

OBJECTIVE : To compare the CTG tracings products without mothers Pregnancy Induced Hypertension (PIH) and contrasted with the state of the newborn. MATERIAL AND MÉTOD0S : Cohort study of 6 months in the Perinatal Maternal Institute , reviewing a total of 287 CTG records , of which 116 were discarded...

Descripción completa

Detalles Bibliográficos
Autor: Angulo Cárdenas, David
Formato: artículo
Fecha de Publicación:1998
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:revistasinvestigacion.unmsm.edu.pe:article/4636
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4636
Nivel de acceso:acceso abierto
Materia:Cardiotography
Gestosis by EPH
Preeclatnpsia
Cardiotografia
Gestosis por EPH
id REVUNMSM_de3c49bd8e307d2b85ec534ca691cb94
oai_identifier_str oai:revistasinvestigacion.unmsm.edu.pe:article/4636
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling Cardiotocography Properties Mothers with Pregnancy Induced HypertensionCaracterísticas Cardiotocográficas del Producto de Madres con Hipertensión Inducida por el EmbarazoAngulo Cárdenas, DavidCardiotographyGestosis by EPHPreeclatnpsiaCardiotografiaGestosis por EPHPreeclatnpsiaOBJECTIVE : To compare the CTG tracings products without mothers Pregnancy Induced Hypertension (PIH) and contrasted with the state of the newborn. MATERIAL AND MÉTOD0S : Cohort study of 6 months in the Perinatal Maternal Institute , reviewing a total of 287 CTG records , of which 116 were discarded . Ninety-six plots were to mothers with PIH and 75 mothers without PIH . Baseline (LB) , variability , accelerations , decelerations , Movements Fetal vibroacoustic stimulation Reactivity : The following parameters were evaluated. RESULTS : The LB was within the normal range in the 95.83 % of hypertensive and 100 % of pregnant control. The RR of variability < 5 beats/min in hypertensive patients was 1.43 (95 % CI) . High risk of doing < 5 min accelerations in 30 products to mothers with PIH was found. No slowdowns type II products HIE mothers evidenced. CONCLUSlONS : The product features cardiotocography mothers with PIH are: LB 120-160 beats/min , variability < 5 beats/min , less than 5 accelerations in 30 min and hypoactivity.OBJETIVO: Comparar los trazados cardiotocográficos de los productos de madres con y sin Hipertensión Inducida por el Embarazo (HIE) y contrastado con el estado del recién nacido. MATERIAL Y MÉTOD0S: Estudio de cohortes de 6 meses en el Instituto Materno Perinatal, revisando un total de 287 registros cardiotocográficos, de los cuales se descartaron 116. Noventa y seis trazados correspondieron a madres con HIE y 75 a madres sin HIE. Se evaluó los siguientes parámetros: Línea de base (LB), Variabilidad, Aceleraciones, Desaceleraciones, Movimientos Fetales, Reactividad al estímulo Vibroacústico. RESULTADOS: La LB se encontró dentro de los valores normales en el 95,83% de las hipertensas y en el 100% de las gestantes control. El RR de presentar Variabilidad < 5 latidos/min en hipertensas fue 1,43 (IC 95%). Se encontró riesgo elevado de hacer < 5 aceleraciones en 30 min en productos de madres con HIE. No se evidenció desaceleraciones tipo II en productos de madres sin HIE. CONCLUSlONES: Las características cardiotocográficas de productos de madres con HIE son: LB entre 120-160 latidos/min, variabilidad <5 latidos/min, menos de 5 aceleraciones en 30 min e hipoactividad.Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana1998-06-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/463610.15381/anales.v59i2.4636Anales de la Facultad de Medicina; Vol. 59 No. 2 (1998); 130-144Anales de la Facultad de Medicina; Vol. 59 Núm. 2 (1998); 130-1441609-94191025-5583reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4636/3711Derechos de autor 1998 David Angulo Cárdenashttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:revistasinvestigacion.unmsm.edu.pe:article/46362020-04-13T12:49:45Z
dc.title.none.fl_str_mv Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
Características Cardiotocográficas del Producto de Madres con Hipertensión Inducida por el Embarazo
title Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
spellingShingle Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
Angulo Cárdenas, David
Cardiotography
Gestosis by EPH
Preeclatnpsia
Cardiotografia
Gestosis por EPH
Preeclatnpsia
title_short Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
title_full Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
title_fullStr Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
title_full_unstemmed Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
title_sort Cardiotocography Properties Mothers with Pregnancy Induced Hypertension
dc.creator.none.fl_str_mv Angulo Cárdenas, David
author Angulo Cárdenas, David
author_facet Angulo Cárdenas, David
author_role author
dc.subject.none.fl_str_mv Cardiotography
Gestosis by EPH
Preeclatnpsia
Cardiotografia
Gestosis por EPH
Preeclatnpsia
topic Cardiotography
Gestosis by EPH
Preeclatnpsia
Cardiotografia
Gestosis por EPH
Preeclatnpsia
description OBJECTIVE : To compare the CTG tracings products without mothers Pregnancy Induced Hypertension (PIH) and contrasted with the state of the newborn. MATERIAL AND MÉTOD0S : Cohort study of 6 months in the Perinatal Maternal Institute , reviewing a total of 287 CTG records , of which 116 were discarded . Ninety-six plots were to mothers with PIH and 75 mothers without PIH . Baseline (LB) , variability , accelerations , decelerations , Movements Fetal vibroacoustic stimulation Reactivity : The following parameters were evaluated. RESULTS : The LB was within the normal range in the 95.83 % of hypertensive and 100 % of pregnant control. The RR of variability < 5 beats/min in hypertensive patients was 1.43 (95 % CI) . High risk of doing < 5 min accelerations in 30 products to mothers with PIH was found. No slowdowns type II products HIE mothers evidenced. CONCLUSlONS : The product features cardiotocography mothers with PIH are: LB 120-160 beats/min , variability < 5 beats/min , less than 5 accelerations in 30 min and hypoactivity.
publishDate 1998
dc.date.none.fl_str_mv 1998-06-15
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4636
10.15381/anales.v59i2.4636
url https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4636
identifier_str_mv 10.15381/anales.v59i2.4636
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/4636/3711
dc.rights.none.fl_str_mv Derechos de autor 1998 David Angulo Cárdenas
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 1998 David Angulo Cárdenas
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana
dc.source.none.fl_str_mv Anales de la Facultad de Medicina; Vol. 59 No. 2 (1998); 130-144
Anales de la Facultad de Medicina; Vol. 59 Núm. 2 (1998); 130-144
1609-9419
1025-5583
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1848424332663980032
score 13.881255
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).