Dosimetric evaluation for treatment using radiochromic films

Descripción del Articulo

In radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic f...

Descripción completa

Detalles Bibliográficos
Autores: Orbegoso, Carlos, Márquez, J. Fernando, Páucar, Rolando
Formato: artículo
Fecha de Publicación:2009
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/8714
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714
Nivel de acceso:acceso abierto
Materia:Películas radiocrómicas
Dosimetría
Braquiterapia ocular
Radiochromic films
Dosimetry
Ocular brachyterapy
id REVUNMSM_bd51fb9e08d6f117425198ee9628794d
oai_identifier_str oai:ojs.csi.unmsm:article/8714
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling Dosimetric evaluation for treatment using radiochromic filmsEvaluación Dosimétrica para tratamientos usando películas radiocrómicasOrbegoso, CarlosMárquez, J. FernandoPáucar, RolandoPelículas radiocrómicasDosimetríaBraquiterapia ocularRadiochromic filmsDosimetryOcular brachyterapyIn radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic films GafChromic MD-55-2, which were characterized and calibrated. There was designed the geometry of the ocular implant for then to measure the dose for different positions relative to the axial axis of the applicator. The results will be confirmed with values obtained by the technology TLD and by values given by the System of Planning Prowess 3000 version 3.06. Dosimetry for radiochromic films they reproduce the values of dose obtained by the methods of planning in Prowess and dosimetría TLD with relative minor differences to the 1 % and 6 %, respectively. For it, the radiochromic films turn into a very valuable tool to be able to realize with enough precision and accuracy the dosimetry of ocular brachyterapy.En radioterapia uno de los más grandes problemas que surge es la precisión en la medición de la dosis absorbida por el tejido tumoroso y en el tejido sano, un dosímetro apropiado para la medida de esta dosis es la película radiocrómica. En este trabajo tiene como objetivo evaluar la dosis adsorbida con películas radiocrómicas GafChromic® MD-55-2, las cuales fueron caracterizadas y calibradas. Se diseñó la geometría del implante ocular para luego medir la dosis para diferentes posiciones relativas al eje axial del aplicador. Los resultados son contrastados con valores obtenidos por la técnica TLD y por valores dados por el Sistema de Planificación Prowess 3000 versión 3.06. La dosimetría por películas radiocrómicas reproducen los valores de dosis obtenidos por los métodos de Planificación en Prowess y dosimetría TLD con diferencias menores entre 1 al 6%. Por ello, las películas radiocrómicas se convierten en una herramientaUniversidad Nacional Mayor de San Marcos2009-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/871410.15381/rif.v12i02.8714Revista de Investigación de Física; Vol. 12 No. 02 (2009); 44-50Revista de Investigación de Física; Vol. 12 Núm. 02 (2009); 44-501728-29771605-7724reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714/7564Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucarhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/87142020-09-03T17:29:44Z
dc.title.none.fl_str_mv Dosimetric evaluation for treatment using radiochromic films
Evaluación Dosimétrica para tratamientos usando películas radiocrómicas
title Dosimetric evaluation for treatment using radiochromic films
spellingShingle Dosimetric evaluation for treatment using radiochromic films
Orbegoso, Carlos
Películas radiocrómicas
Dosimetría
Braquiterapia ocular
Radiochromic films
Dosimetry
Ocular brachyterapy
title_short Dosimetric evaluation for treatment using radiochromic films
title_full Dosimetric evaluation for treatment using radiochromic films
title_fullStr Dosimetric evaluation for treatment using radiochromic films
title_full_unstemmed Dosimetric evaluation for treatment using radiochromic films
title_sort Dosimetric evaluation for treatment using radiochromic films
dc.creator.none.fl_str_mv Orbegoso, Carlos
Márquez, J. Fernando
Páucar, Rolando
author Orbegoso, Carlos
author_facet Orbegoso, Carlos
Márquez, J. Fernando
Páucar, Rolando
author_role author
author2 Márquez, J. Fernando
Páucar, Rolando
author2_role author
author
dc.subject.none.fl_str_mv Películas radiocrómicas
Dosimetría
Braquiterapia ocular
Radiochromic films
Dosimetry
Ocular brachyterapy
topic Películas radiocrómicas
Dosimetría
Braquiterapia ocular
Radiochromic films
Dosimetry
Ocular brachyterapy
description In radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic films GafChromic MD-55-2, which were characterized and calibrated. There was designed the geometry of the ocular implant for then to measure the dose for different positions relative to the axial axis of the applicator. The results will be confirmed with values obtained by the technology TLD and by values given by the System of Planning Prowess 3000 version 3.06. Dosimetry for radiochromic films they reproduce the values of dose obtained by the methods of planning in Prowess and dosimetría TLD with relative minor differences to the 1 % and 6 %, respectively. For it, the radiochromic films turn into a very valuable tool to be able to realize with enough precision and accuracy the dosimetry of ocular brachyterapy.
publishDate 2009
dc.date.none.fl_str_mv 2009-12-31
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714
10.15381/rif.v12i02.8714
url https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714
identifier_str_mv 10.15381/rif.v12i02.8714
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714/7564
dc.rights.none.fl_str_mv Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucar
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucar
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Revista de Investigación de Física; Vol. 12 No. 02 (2009); 44-50
Revista de Investigación de Física; Vol. 12 Núm. 02 (2009); 44-50
1728-2977
1605-7724
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1795238318763409408
score 13.90587
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).