Dosimetric evaluation for treatment using radiochromic films
Descripción del Articulo
In radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic f...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2009 |
| Institución: | Universidad Nacional Mayor de San Marcos |
| Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.csi.unmsm:article/8714 |
| Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714 |
| Nivel de acceso: | acceso abierto |
| Materia: | Películas radiocrómicas Dosimetría Braquiterapia ocular Radiochromic films Dosimetry Ocular brachyterapy |
| id |
REVUNMSM_bd51fb9e08d6f117425198ee9628794d |
|---|---|
| oai_identifier_str |
oai:ojs.csi.unmsm:article/8714 |
| network_acronym_str |
REVUNMSM |
| network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository_id_str |
|
| spelling |
Dosimetric evaluation for treatment using radiochromic filmsEvaluación Dosimétrica para tratamientos usando películas radiocrómicasOrbegoso, CarlosMárquez, J. FernandoPáucar, RolandoPelículas radiocrómicasDosimetríaBraquiterapia ocularRadiochromic filmsDosimetryOcular brachyterapyIn radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic films GafChromic MD-55-2, which were characterized and calibrated. There was designed the geometry of the ocular implant for then to measure the dose for different positions relative to the axial axis of the applicator. The results will be confirmed with values obtained by the technology TLD and by values given by the System of Planning Prowess 3000 version 3.06. Dosimetry for radiochromic films they reproduce the values of dose obtained by the methods of planning in Prowess and dosimetría TLD with relative minor differences to the 1 % and 6 %, respectively. For it, the radiochromic films turn into a very valuable tool to be able to realize with enough precision and accuracy the dosimetry of ocular brachyterapy.En radioterapia uno de los más grandes problemas que surge es la precisión en la medición de la dosis absorbida por el tejido tumoroso y en el tejido sano, un dosímetro apropiado para la medida de esta dosis es la película radiocrómica. En este trabajo tiene como objetivo evaluar la dosis adsorbida con películas radiocrómicas GafChromic® MD-55-2, las cuales fueron caracterizadas y calibradas. Se diseñó la geometría del implante ocular para luego medir la dosis para diferentes posiciones relativas al eje axial del aplicador. Los resultados son contrastados con valores obtenidos por la técnica TLD y por valores dados por el Sistema de Planificación Prowess 3000 versión 3.06. La dosimetría por películas radiocrómicas reproducen los valores de dosis obtenidos por los métodos de Planificación en Prowess y dosimetría TLD con diferencias menores entre 1 al 6%. Por ello, las películas radiocrómicas se convierten en una herramientaUniversidad Nacional Mayor de San Marcos2009-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/871410.15381/rif.v12i02.8714Revista de Investigación de Física; Vol. 12 No. 02 (2009); 44-50Revista de Investigación de Física; Vol. 12 Núm. 02 (2009); 44-501728-29771605-7724reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714/7564Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucarhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/87142020-09-03T17:29:44Z |
| dc.title.none.fl_str_mv |
Dosimetric evaluation for treatment using radiochromic films Evaluación Dosimétrica para tratamientos usando películas radiocrómicas |
| title |
Dosimetric evaluation for treatment using radiochromic films |
| spellingShingle |
Dosimetric evaluation for treatment using radiochromic films Orbegoso, Carlos Películas radiocrómicas Dosimetría Braquiterapia ocular Radiochromic films Dosimetry Ocular brachyterapy |
| title_short |
Dosimetric evaluation for treatment using radiochromic films |
| title_full |
Dosimetric evaluation for treatment using radiochromic films |
| title_fullStr |
Dosimetric evaluation for treatment using radiochromic films |
| title_full_unstemmed |
Dosimetric evaluation for treatment using radiochromic films |
| title_sort |
Dosimetric evaluation for treatment using radiochromic films |
| dc.creator.none.fl_str_mv |
Orbegoso, Carlos Márquez, J. Fernando Páucar, Rolando |
| author |
Orbegoso, Carlos |
| author_facet |
Orbegoso, Carlos Márquez, J. Fernando Páucar, Rolando |
| author_role |
author |
| author2 |
Márquez, J. Fernando Páucar, Rolando |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Películas radiocrómicas Dosimetría Braquiterapia ocular Radiochromic films Dosimetry Ocular brachyterapy |
| topic |
Películas radiocrómicas Dosimetría Braquiterapia ocular Radiochromic films Dosimetry Ocular brachyterapy |
| description |
In radiotherapy one of the biggest problems that arises is the uncertainty in the measurement of the dose absorbed by the tumorous and healthy tissue a dosimeter appropriated for dosimetry measurement are the radiochromic films. This work there as objective dose adsorbed evaluate with radiochromic films GafChromic MD-55-2, which were characterized and calibrated. There was designed the geometry of the ocular implant for then to measure the dose for different positions relative to the axial axis of the applicator. The results will be confirmed with values obtained by the technology TLD and by values given by the System of Planning Prowess 3000 version 3.06. Dosimetry for radiochromic films they reproduce the values of dose obtained by the methods of planning in Prowess and dosimetría TLD with relative minor differences to the 1 % and 6 %, respectively. For it, the radiochromic films turn into a very valuable tool to be able to realize with enough precision and accuracy the dosimetry of ocular brachyterapy. |
| publishDate |
2009 |
| dc.date.none.fl_str_mv |
2009-12-31 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714 10.15381/rif.v12i02.8714 |
| url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714 |
| identifier_str_mv |
10.15381/rif.v12i02.8714 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/8714/7564 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucar https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2009 Carlos Orbegoso, J. Fernando Márquez, Rolando Páucar https://creativecommons.org/licenses/by-nc-sa/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
| publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
| dc.source.none.fl_str_mv |
Revista de Investigación de Física; Vol. 12 No. 02 (2009); 44-50 Revista de Investigación de Física; Vol. 12 Núm. 02 (2009); 44-50 1728-2977 1605-7724 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
| instname_str |
Universidad Nacional Mayor de San Marcos |
| instacron_str |
UNMSM |
| institution |
UNMSM |
| reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| collection |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1795238318763409408 |
| score |
13.90587 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).