The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory

Descripción del Articulo

Microbiological air quality (MAQ) was monitored in the agrobiological products quality laboratory before and after the application of the "5S" methodology. The results were obtained through the agar-plate sedimentation method, carried out via biweekly sampling from April to June and from S...

Descripción completa

Detalles Bibliográficos
Autores: Huánuco, Lucía, Rosales López, Pedro Pablo
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:revistasinvestigacion.unmsm.edu.pe:article/15599
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599
Nivel de acceso:acceso abierto
Materia:5S
microbiological air quality
CFU
laboratory
Calidad microbiológica del aire
UFC
laboratorio
id REVUNMSM_1af6480f109755aece1c41eb0acf2974
oai_identifier_str oai:revistasinvestigacion.unmsm.edu.pe:article/15599
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratoryImpacto de las 5S en la Calidad Microbiológica del Aire del laboratorio de calidad de productos agrobiológicosHuánuco, LucíaRosales López, Pedro Pablo5Smicrobiological air qualityCFUlaboratory5SCalidad microbiológica del aireUFClaboratorioMicrobiological air quality (MAQ) was monitored in the agrobiological products quality laboratory before and after the application of the "5S" methodology. The results were obtained through the agar-plate sedimentation method, carried out via biweekly sampling from April to June and from September to November of 2017, keeping temperature and relative humidity parameters constant (23 + 2 ° C and 62 + 3%). The initial level of 5S achieved only 43% of compliance, considered as "Below average", obtaining in this instance MAQ sampling distributed among fungi of 25 CFU/plate (50%), followed by bacteria at 16 CFU/plate (33%) and yeast at 8 CFU/plate (17%). In contrast, after carrying out 5S implementation, a result of 91% or "Excellent" level was obtained, which had fungal counts of 14 CFU/plate and 1 CFU/plate for the case of bacteria and yeasts. That is to say, the total microbial load decreased 68% between both conditions. By means of Student’s T test for means of related samples, significant differences in Microbiological Air Quality before and after 5S implementation at the laboratory studied were confirmed.Se monitoreó la calidad microbiológica del aire (CMA) en el laboratorio de Calidad de productos agrobiológicos antes y después de la aplicación de la metodología “5S”. Los resultados se obtuvieron por medio del Método de sedimentación en placa de agar, mediante el muestreo quincenal durante los meses de Abril a Junio y de Setiembre a Noviembre de 2017; manteniendo constante los parámetros de temperatura y humedad relativa (23 + 2 °C y 62 + 3 %). El nivel inicial de las 5S logró solo el 43% de cumplimiento, considerado como “Por debajo del promedio”; obteniéndose en esta instancia la CMA distribuida entre hongos a 25 UFC/ placa (50%), seguido por las bacterias a 16 UFC/placa (33%) y por último las levaduras a 8 UFC/placa (17%). En cambio, luego de llevar a cabo la implementación de las 5S, se obtuvo un resultado al 91% o nivel “Excelente” de cumplimiento, lo cual tuvo recuentos fúngicos de 14 UFC/placa y 1 UFC/ placa para el caso de las bacterias y levaduras; es decir, la carga microbiana total disminuyó en un 68% entre ambas condiciones. Mediante la prueba estadística “T student” para medias de muestras relacionadas, se confirmó las diferencias significativas de la Calidad Microbiológica del aire antes y después de las 5S en el laboratorio en estudio.Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos2018-12-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/1559910.15381/idata.v21i2.15599Industrial Data; Vol. 21 Núm. 2 (2018); 17-24Industrial Data; Vol. 21 No. 2 (2018); 17-241810-99931560-9146reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599/13373Derechos de autor 2018 Lucía Huánuco, Pedro Pablo Rosales Lópezhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:revistasinvestigacion.unmsm.edu.pe:article/155992021-07-14T09:59:27Z
dc.title.none.fl_str_mv The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
Impacto de las 5S en la Calidad Microbiológica del Aire del laboratorio de calidad de productos agrobiológicos
title The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
spellingShingle The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
Huánuco, Lucía
5S
microbiological air quality
CFU
laboratory
5S
Calidad microbiológica del aire
UFC
laboratorio
title_short The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
title_full The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
title_fullStr The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
title_full_unstemmed The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
title_sort The impact of 5S on Microbiological Air Quality of an agrobiological products quality laboratory
dc.creator.none.fl_str_mv Huánuco, Lucía
Rosales López, Pedro Pablo
author Huánuco, Lucía
author_facet Huánuco, Lucía
Rosales López, Pedro Pablo
author_role author
author2 Rosales López, Pedro Pablo
author2_role author
dc.subject.none.fl_str_mv 5S
microbiological air quality
CFU
laboratory
5S
Calidad microbiológica del aire
UFC
laboratorio
topic 5S
microbiological air quality
CFU
laboratory
5S
Calidad microbiológica del aire
UFC
laboratorio
description Microbiological air quality (MAQ) was monitored in the agrobiological products quality laboratory before and after the application of the "5S" methodology. The results were obtained through the agar-plate sedimentation method, carried out via biweekly sampling from April to June and from September to November of 2017, keeping temperature and relative humidity parameters constant (23 + 2 ° C and 62 + 3%). The initial level of 5S achieved only 43% of compliance, considered as "Below average", obtaining in this instance MAQ sampling distributed among fungi of 25 CFU/plate (50%), followed by bacteria at 16 CFU/plate (33%) and yeast at 8 CFU/plate (17%). In contrast, after carrying out 5S implementation, a result of 91% or "Excellent" level was obtained, which had fungal counts of 14 CFU/plate and 1 CFU/plate for the case of bacteria and yeasts. That is to say, the total microbial load decreased 68% between both conditions. By means of Student’s T test for means of related samples, significant differences in Microbiological Air Quality before and after 5S implementation at the laboratory studied were confirmed.
publishDate 2018
dc.date.none.fl_str_mv 2018-12-20
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599
10.15381/idata.v21i2.15599
url https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599
identifier_str_mv 10.15381/idata.v21i2.15599
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/15599/13373
dc.rights.none.fl_str_mv Derechos de autor 2018 Lucía Huánuco, Pedro Pablo Rosales López
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2018 Lucía Huánuco, Pedro Pablo Rosales López
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Industrial Data; Vol. 21 Núm. 2 (2018); 17-24
Industrial Data; Vol. 21 No. 2 (2018); 17-24
1810-9993
1560-9146
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1848424571742453760
score 13.9378
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).