The effect of the porous bed in a solar air heater with a V-corrugated absorbent plate and a design that facilitates free convection is analyzed, in terms of performance parameters and thermal efficiency. The collector was evaluated, with and without porous bed, under similar climatic conditions whe...

Descripción completa

Detalles Bibliográficos
Autor: Quiñonez Choquecota, Jose
Formato: artículo
Fecha de Publicación:2021
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/1060
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060
Nivel de acceso:acceso abierto
Materia:abastecimiento de energía
balance energético
calefacción solar
transferencia de calor
energy supply
energy balance
solar heating
heat tranfer
id REVUNI_fb487f33cbb610bed2814ba3a974af34
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/1060
network_acronym_str REVUNI
network_name_str Revistas - Universidad Nacional de Ingeniería
repository_id_str
spelling Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bedAnálisis del rendimiento térmico de un calentador solar de aire de convección natural con absorbente corrugado y lecho porosoQuiñonez Choquecota, Joseabastecimiento de energíabalance energéticocalefacción solartransferencia de calorenergy supplyenergy balancesolar heatingheat tranferThe effect of the porous bed in a solar air heater with a V-corrugated absorbent plate and a design that facilitates free convection is analyzed, in terms of performance parameters and thermal efficiency. The collector was evaluated, with and without porous bed, under similar climatic conditions when mounted on a vertical wall. The results revealed that the mass flow is directly affected by the ambient temperature. It was observed that the porous bed affects the laminar sublayer of the absorbent plate generating greater turbulence that improves the rate of heat transfer, therefore, the collector with a porous bed presents a higher temperature inside and slightly decreases its efficiency. In addition, the porous bed works as a heat store that reduces instabilities which allows a uniform outlet temperature and allows to increase the operating time. The collector is inexpensive, respectful with the environment and feasible for space heating in frigid areas.Se analiza el efecto del lecho poroso en un calentador solar de aire con placa absorbente corrugado en V y un diseño que facilita la libre convección, en términos de parámetros de rendimiento y eficiencia térmica. El colector se evaluó, con y sin lecho poroso, en condiciones climáticas similares al montar sobre una pared vertical. Los resultados revelaron que el flujo másico está directamente afectado con la temperatura ambiente. Se observó que el lecho poroso afecta la subcapa laminar de la placa absorbente generando mayor turbulencia que mejora la tasa de transferencia de calor, por tanto, el colector con lecho poroso presenta mayor temperatura en su interior y disminuye ligeramente su eficiencia. Además, el lecho poroso funciona como almacén de calor que reduce inestabilidades lo cual permite una temperatura de salida uniforme y permite aumentar el tiempo de funcionamiento. El colector es de bajo costo, es respetuoso con el medio ambiente y factible para calefacción de ambientes en zonas frígidas.Universidad Nacional de Ingeniería2021-07-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/xmlhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/106010.21754/tecnia.v21i2.1060TECNIA; Vol. 31 No. 2 (2021); 90-96TECNIA; Vol. 31 Núm. 2 (2021); 90-962309-04130375-776510.21754/tecnia.v31i2reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/1060/1748https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060/1897Derechos de autor 2021 TECNIAinfo:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/10602025-07-15T00:11:02Z
dc.title.none.fl_str_mv Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
Análisis del rendimiento térmico de un calentador solar de aire de convección natural con absorbente corrugado y lecho poroso
title Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
spellingShingle Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
Quiñonez Choquecota, Jose
abastecimiento de energía
balance energético
calefacción solar
transferencia de calor
energy supply
energy balance
solar heating
heat tranfer
title_short Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
title_full Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
title_fullStr Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
title_full_unstemmed Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
title_sort Thermal performance analysis of a natural convection air solar heater with corrugated absorbent and porous bed
dc.creator.none.fl_str_mv Quiñonez Choquecota, Jose
author Quiñonez Choquecota, Jose
author_facet Quiñonez Choquecota, Jose
author_role author
dc.subject.none.fl_str_mv abastecimiento de energía
balance energético
calefacción solar
transferencia de calor
energy supply
energy balance
solar heating
heat tranfer
topic abastecimiento de energía
balance energético
calefacción solar
transferencia de calor
energy supply
energy balance
solar heating
heat tranfer
description The effect of the porous bed in a solar air heater with a V-corrugated absorbent plate and a design that facilitates free convection is analyzed, in terms of performance parameters and thermal efficiency. The collector was evaluated, with and without porous bed, under similar climatic conditions when mounted on a vertical wall. The results revealed that the mass flow is directly affected by the ambient temperature. It was observed that the porous bed affects the laminar sublayer of the absorbent plate generating greater turbulence that improves the rate of heat transfer, therefore, the collector with a porous bed presents a higher temperature inside and slightly decreases its efficiency. In addition, the porous bed works as a heat store that reduces instabilities which allows a uniform outlet temperature and allows to increase the operating time. The collector is inexpensive, respectful with the environment and feasible for space heating in frigid areas.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-25
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060
10.21754/tecnia.v21i2.1060
url https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060
identifier_str_mv 10.21754/tecnia.v21i2.1060
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060/1748
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1060/1897
dc.rights.none.fl_str_mv Derechos de autor 2021 TECNIA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2021 TECNIA
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/xml
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol. 31 No. 2 (2021); 90-96
TECNIA; Vol. 31 Núm. 2 (2021); 90-96
2309-0413
0375-7765
10.21754/tecnia.v31i2
reponame:Revistas - Universidad Nacional de Ingeniería
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str Revistas - Universidad Nacional de Ingeniería
collection Revistas - Universidad Nacional de Ingeniería
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1838636205266173952
score 13.860459
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).