Design and implementation of an electronic stimulator
Descripción del Articulo
The project was developed within the frame and standards that are included in the field of studies ofthe medicine; its internal architecture designed using integrated circuits compact, so is the case of the generator of signals ICL8038, that provides three types of signal of variable frequency, to t...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2005 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/456 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/456 |
Nivel de acceso: | acceso abierto |
Materia: | Medicina Circuitos integrados Frecuencia Organismos vivos Medicine Integrated circuits Frequency Alive organisms |
id |
REVUNI_ad8606f97ad8152357ffecfaa5ce8488 |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/456 |
network_acronym_str |
REVUNI |
network_name_str |
Revistas - Universidad Nacional de Ingeniería |
repository_id_str |
|
spelling |
Design and implementation of an electronic stimulatorDiseño e iplementación de un estimulador electrónico del Carpio Salinas, JorgeRomero Cacha, Miguel ÁngelMedicina Circuitos integradosFrecuenciaOrganismos vivosMedicineIntegrated circuitsFrequencyAlive organismsThe project was developed within the frame and standards that are included in the field of studies ofthe medicine; its internal architecture designed using integrated circuits compact, so is the case of the generator of signals ICL8038, that provides three types of signal of variable frequency, to thisadds the implementation of an amplifying stage conformed by CI STK086, that maintains the frequency and signal form to amplify itself. The implemented electronic estimulador has the capacity to generate three types of electrical signal (sine, triangular and square) and simultaneously these have thecharacteristics to vary its Amplitude and frequency for this way being applied to weaves of alive organisms and to analyze its physical and electrical behavior.El proyecto se desarrollo dentro del marco y estándares que se tienen en el campo de estudios de la medicina; su arquitectura interna se diseño utilizando circuitos integrados compactos, tal es el casodel generador de señales ICL8038, quien proporciona tres tipos de señal de frecuencia variable, a esto se suma la implementación de una etapa amplificadora conformada por el CI STK086, quien mantiene la frecuencia y forma de señal a amplificarse. El estimulador electrónico implementado tiene la capacidad de generar tres tipos de señal eléctrica (senoidal, triangular y cuadrada) y a la vez estas tienen la características de variar su amplitud y frecuencia para de esta manera seraplicado a tejidos de organismos vivos y analizar su comportamiento fisico y eléctrico.Universidad Nacional de Ingeniería2005-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/45610.21754/tecnia.v15i1.456TECNIA; Vol. 15 No. 1 (2005)TECNIA; Vol. 15 Núm. 1 (2005)2309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/456/407Derechos de autor 2005 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/4562023-12-04T17:57:57Z |
dc.title.none.fl_str_mv |
Design and implementation of an electronic stimulator Diseño e iplementación de un estimulador electrónico |
title |
Design and implementation of an electronic stimulator |
spellingShingle |
Design and implementation of an electronic stimulator del Carpio Salinas, Jorge Medicina Circuitos integrados Frecuencia Organismos vivos Medicine Integrated circuits Frequency Alive organisms |
title_short |
Design and implementation of an electronic stimulator |
title_full |
Design and implementation of an electronic stimulator |
title_fullStr |
Design and implementation of an electronic stimulator |
title_full_unstemmed |
Design and implementation of an electronic stimulator |
title_sort |
Design and implementation of an electronic stimulator |
dc.creator.none.fl_str_mv |
del Carpio Salinas, Jorge Romero Cacha, Miguel Ángel |
author |
del Carpio Salinas, Jorge |
author_facet |
del Carpio Salinas, Jorge Romero Cacha, Miguel Ángel |
author_role |
author |
author2 |
Romero Cacha, Miguel Ángel |
author2_role |
author |
dc.subject.none.fl_str_mv |
Medicina Circuitos integrados Frecuencia Organismos vivos Medicine Integrated circuits Frequency Alive organisms |
topic |
Medicina Circuitos integrados Frecuencia Organismos vivos Medicine Integrated circuits Frequency Alive organisms |
description |
The project was developed within the frame and standards that are included in the field of studies ofthe medicine; its internal architecture designed using integrated circuits compact, so is the case of the generator of signals ICL8038, that provides three types of signal of variable frequency, to thisadds the implementation of an amplifying stage conformed by CI STK086, that maintains the frequency and signal form to amplify itself. The implemented electronic estimulador has the capacity to generate three types of electrical signal (sine, triangular and square) and simultaneously these have thecharacteristics to vary its Amplitude and frequency for this way being applied to weaves of alive organisms and to analyze its physical and electrical behavior. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-06-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/456 10.21754/tecnia.v15i1.456 |
url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/456 |
identifier_str_mv |
10.21754/tecnia.v15i1.456 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/456/407 |
dc.rights.none.fl_str_mv |
Derechos de autor 2005 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2005 TECNIA http://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol. 15 No. 1 (2005) TECNIA; Vol. 15 Núm. 1 (2005) 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
reponame_str |
Revistas - Universidad Nacional de Ingeniería |
collection |
Revistas - Universidad Nacional de Ingeniería |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1833562778018775040 |
score |
13.871978 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).