Experimental study of confined masonry walls against perpendicular loads by tsunami
Descripción del Articulo
The high seismic activity on the Peruvian coast carries a potential risk of tsunamis that could affect the Peruvian coast, causing damage to people and structures. According to studies carried out by CISMID and Fondecyt, approximately 83% of the houses in Metropolitan Lima and Callao are made of mas...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2024 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revistas - Universidad Nacional de Ingeniería |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/1966 |
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/1966 |
| Nivel de acceso: | acceso abierto |
| Materia: | Albañilería confinada tsunami sismicidad capacidad estructural Confined masonry seismicity structural capacity |
| id |
REVUNI_33988f98ddbbb85cb61bb983529c7a39 |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/1966 |
| network_acronym_str |
REVUNI |
| network_name_str |
Revistas - Universidad Nacional de Ingeniería |
| repository_id_str |
|
| spelling |
Experimental study of confined masonry walls against perpendicular loads by tsunamiEstudio experimental de muros de albañilería confinada frente a cargas perpendiculares por tsunamiCamacho Roque, ChryslerZavala Toledo, CarlosReyna Salazar, RoyAlbañilería confinadatsunamisismicidadcapacidad estructuralConfined masonrytsunamiseismicitystructural capacityThe high seismic activity on the Peruvian coast carries a potential risk of tsunamis that could affect the Peruvian coast, causing damage to people and structures. According to studies carried out by CISMID and Fondecyt, approximately 83% of the houses in Metropolitan Lima and Callao are made of masonry, mainly due to its low economic cost. The present experimental study aims to study the behavior of confined masonry walls under the action of perpendicular loads to the wall produced by the impact of tsunami waves, which is a field of research where it is still necessary to delve deeper with experimental studies of the structures under equivalent tsunami loads. As part of the experimental study, 2 confined masonry walls were built, which were tested under the action of perpendicular loads applied by means of hydraulic jacks with a force control simulating the forces induced by a tsunami. From the experimental test, a failure was obtained by bending perpendicular to the plane of the main wall reaching a total load equivalent to a maximum height of the wave train of 3.95 m for a distortion of 1/75 at the level of the lightened slab. In addition, the limit deformation for confined masonry structures indicated in the Peruvian Standard E030 was reached for a load equivalent to a maximum height of the wave train of 3.00La alta actividad sísmica en la costa del Perú conlleva a un riesgo potencial de tsunamis que podrían afectar la costa peruana incurriendo en daños a las personas y a las estructuras. De acuerdo con estudios realizados por el CISMID y el Fondecyt aproximadamente el 83% de las viviendas en Lima Metropolitana y el Callao corresponde a albañilería esto principalmente debido a su bajo costo económico. El presente estudio experimental tiene por objetivo estudiar el comportamiento de los muros de albañilería confinada bajo acción de cargas perpendiculares al muro producidas por el impacto de las olas de un tsunami, el cual es un campo de investigación donde aún es necesario ahondar con estudios experimentales de las estructuras ante cargas de tsunami equivalentes. Como parte del estudio experimental se construyeron 2 muros de albañilería confinada, los cuales se ensayaron bajó acción de cargas perpendiculares aplicadas por medio de gatas hidráulicas con un control por fuerza simulando las fuerzas inducidas por un tsunami. Del ensayo experimental se obtuvo una falla por flexión perpendicular al plano del muro principal alcanzando una carga total equivalente a una altura máxima del tren de olas de 3.95 m de altura para una distorsión de 1/75 al nivel de la losa aligerada. Además, se alcanzó la deformación límite para estructuras de albañilería confinada indicada en la Norma Peruana E030 para una carga equivalente a una altura máxima del tren de olas de 3.00 m.Universidad Nacional de Ingeniería2024-12-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/196610.21754/tecnia.v34i2.1966TECNIA; Vol. 34 No. 2 (2024); 18-27TECNIA; Vol. 34 Núm. 2 (2024); 18-272309-04130375-776510.21754/tecnia.v34i2reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/1966/3127Derechos de autor 2024 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/19662025-07-16T17:30:44Z |
| dc.title.none.fl_str_mv |
Experimental study of confined masonry walls against perpendicular loads by tsunami Estudio experimental de muros de albañilería confinada frente a cargas perpendiculares por tsunami |
| title |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| spellingShingle |
Experimental study of confined masonry walls against perpendicular loads by tsunami Camacho Roque, Chrysler Albañilería confinada tsunami sismicidad capacidad estructural Confined masonry tsunami seismicity structural capacity |
| title_short |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| title_full |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| title_fullStr |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| title_full_unstemmed |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| title_sort |
Experimental study of confined masonry walls against perpendicular loads by tsunami |
| dc.creator.none.fl_str_mv |
Camacho Roque, Chrysler Zavala Toledo, Carlos Reyna Salazar, Roy |
| author |
Camacho Roque, Chrysler |
| author_facet |
Camacho Roque, Chrysler Zavala Toledo, Carlos Reyna Salazar, Roy |
| author_role |
author |
| author2 |
Zavala Toledo, Carlos Reyna Salazar, Roy |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Albañilería confinada tsunami sismicidad capacidad estructural Confined masonry tsunami seismicity structural capacity |
| topic |
Albañilería confinada tsunami sismicidad capacidad estructural Confined masonry tsunami seismicity structural capacity |
| description |
The high seismic activity on the Peruvian coast carries a potential risk of tsunamis that could affect the Peruvian coast, causing damage to people and structures. According to studies carried out by CISMID and Fondecyt, approximately 83% of the houses in Metropolitan Lima and Callao are made of masonry, mainly due to its low economic cost. The present experimental study aims to study the behavior of confined masonry walls under the action of perpendicular loads to the wall produced by the impact of tsunami waves, which is a field of research where it is still necessary to delve deeper with experimental studies of the structures under equivalent tsunami loads. As part of the experimental study, 2 confined masonry walls were built, which were tested under the action of perpendicular loads applied by means of hydraulic jacks with a force control simulating the forces induced by a tsunami. From the experimental test, a failure was obtained by bending perpendicular to the plane of the main wall reaching a total load equivalent to a maximum height of the wave train of 3.95 m for a distortion of 1/75 at the level of the lightened slab. In addition, the limit deformation for confined masonry structures indicated in the Peruvian Standard E030 was reached for a load equivalent to a maximum height of the wave train of 3.00 |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024-12-26 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1966 10.21754/tecnia.v34i2.1966 |
| url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1966 |
| identifier_str_mv |
10.21754/tecnia.v34i2.1966 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/1966/3127 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2024 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2024 TECNIA http://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol. 34 No. 2 (2024); 18-27 TECNIA; Vol. 34 Núm. 2 (2024); 18-27 2309-0413 0375-7765 10.21754/tecnia.v34i2 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| reponame_str |
Revistas - Universidad Nacional de Ingeniería |
| collection |
Revistas - Universidad Nacional de Ingeniería |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1838636208351084544 |
| score |
13.945474 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).