Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma
Descripción del Articulo
The present research is based on the study of the thermal comfort of the residents of the Minor Population Center of Kallapuma located at 4258 meters above sea level in the district of Tarata, province and region of Tacna. To evaluate the environmental parameters, satisfaction surveys were applied t...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2024 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revistas - Universidad Nacional de Ingeniería |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/2167 |
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/2167 |
| Nivel de acceso: | acceso abierto |
| Materia: | Parámetros ambientales Confort térmico Zona altoandina Temperatura de neutralidad Thermal comfort High andean zone Neutrality temperature Environmental Parameters |
| id |
REVUNI_10c72b04bb985183c6af04774e8471a7 |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/2167 |
| network_acronym_str |
REVUNI |
| network_name_str |
Revistas - Universidad Nacional de Ingeniería |
| repository_id_str |
|
| spelling |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in KallapumaDesarrollo de un modelo de evaluación de parámetros ambientales para lograr el confort térmico en viviendas de KallapumaGirón Pizarro, María LourdesPolo Bravo, Carlos ArmandoGómez León, Mónica MarcelaParámetros ambientalesConfort térmicoZona altoandinaTemperatura de neutralidadThermal comfortHigh andean zoneNeutrality temperatureEnvironmental ParametersThe present research is based on the study of the thermal comfort of the residents of the Minor Population Center of Kallapuma located at 4258 meters above sea level in the district of Tarata, province and region of Tacna. To evaluate the environmental parameters, satisfaction surveys were applied taking into account clothing, nutrition, physical activity and thermal comfort. Likewise, a device called TSVR was used that allowed measuring temperature, relative humidity, perceptions of comfort such as thermal sensation, personal information and clothing worn by the user, called thermal sensation vote (VST). These measurements were taken in the months of May, June and July of 2022. The real acceptability of thermal conditions to users was analyzed. Once the data was obtained, the neutrality temperature and thermal comfort ranges for the population of the Minor Population Center of Kallapuma were identified, taking into account the ASHRAE 55 and ISO 7730 standards and comparing them with models developed by authors such as Fanger, Humphreys, Givoni, among others. Knowing the defined conditions of thermal comfort and the type of population will favor the design of homes in high Andean areas. Expressing the conditions related to temperature, relative humidity and perceptions of thermal comfort facilitates the application of passive environmental conditioning strategies. La presente investigación se basa en el estudio del confort térmico de los pobladores del Centro Poblado Menor de Kallapuma ubicado a 4258 m.s.n.m en el distrito de Tarata, provincia y región de Tacna. Para evaluar los parámetros ambientales se aplicaron encuestas de satisfacción teniendo en cuenta la vestimenta, alimentación, actividad física y la comodidad térmica. Así mismo se utilizó un dispositivo denominado TSVR, que permitió medir la temperatura, humedad relativa, percepciones de confort como la sensación térmica, información personal e indumentaria que utilizaba el usuario, denominado voto de sensación térmica (VST). Estas mediciones fueron tomadas en los meses de mayo, junio y julio del año 2022. Se analizó la aceptabilidad real que tienen los usuarios de las condiciones térmicas. Una vez obtenidos los datos, se identificó la temperatura de neutralidad y los rangos de confort térmico para la población del Centro Poblado Menor de Kallapuma teniendo en cuenta las normas ASHRAE 55 e ISO 7730 y comparándose con modelos desarrollados por autores como Fanger, Humphreys, Givoni, entre otros. Conocer las condiciones definidas de confort térmico y el tipo de población favorecerá el diseño de viviendas en zonas altoandinas. Expresar las condiciones relacionadas a la temperatura, humedad relativa y percepciones de confort térmico facilita la aplicación de estrategias pasivas de acondicionamiento ambiental. Universidad Nacional de Ingeniería2024-12-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionElectrical Engineering and Power SystemsIngeniería Eléctrica y Sistemas de Potenciaapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/216710.21754/tecnia.v34i2.2167TECNIA; Vol. 34 No. 2 (2024); 40-52TECNIA; Vol. 34 Núm. 2 (2024); 40-522309-04130375-776510.21754/tecnia.v34i2reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/2167/3129Derechos de autor 2024 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/21672025-07-16T17:30:44Z |
| dc.title.none.fl_str_mv |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma Desarrollo de un modelo de evaluación de parámetros ambientales para lograr el confort térmico en viviendas de Kallapuma |
| title |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| spellingShingle |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma Girón Pizarro, María Lourdes Parámetros ambientales Confort térmico Zona altoandina Temperatura de neutralidad Thermal comfort High andean zone Neutrality temperature Environmental Parameters |
| title_short |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| title_full |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| title_fullStr |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| title_full_unstemmed |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| title_sort |
Development of an evaluation model of environmental parameters to achieve thermal comfort in homes in Kallapuma |
| dc.creator.none.fl_str_mv |
Girón Pizarro, María Lourdes Polo Bravo, Carlos Armando Gómez León, Mónica Marcela |
| author |
Girón Pizarro, María Lourdes |
| author_facet |
Girón Pizarro, María Lourdes Polo Bravo, Carlos Armando Gómez León, Mónica Marcela |
| author_role |
author |
| author2 |
Polo Bravo, Carlos Armando Gómez León, Mónica Marcela |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Parámetros ambientales Confort térmico Zona altoandina Temperatura de neutralidad Thermal comfort High andean zone Neutrality temperature Environmental Parameters |
| topic |
Parámetros ambientales Confort térmico Zona altoandina Temperatura de neutralidad Thermal comfort High andean zone Neutrality temperature Environmental Parameters |
| description |
The present research is based on the study of the thermal comfort of the residents of the Minor Population Center of Kallapuma located at 4258 meters above sea level in the district of Tarata, province and region of Tacna. To evaluate the environmental parameters, satisfaction surveys were applied taking into account clothing, nutrition, physical activity and thermal comfort. Likewise, a device called TSVR was used that allowed measuring temperature, relative humidity, perceptions of comfort such as thermal sensation, personal information and clothing worn by the user, called thermal sensation vote (VST). These measurements were taken in the months of May, June and July of 2022. The real acceptability of thermal conditions to users was analyzed. Once the data was obtained, the neutrality temperature and thermal comfort ranges for the population of the Minor Population Center of Kallapuma were identified, taking into account the ASHRAE 55 and ISO 7730 standards and comparing them with models developed by authors such as Fanger, Humphreys, Givoni, among others. Knowing the defined conditions of thermal comfort and the type of population will favor the design of homes in high Andean areas. Expressing the conditions related to temperature, relative humidity and perceptions of thermal comfort facilitates the application of passive environmental conditioning strategies. |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024-12-26 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Electrical Engineering and Power Systems Ingeniería Eléctrica y Sistemas de Potencia |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/2167 10.21754/tecnia.v34i2.2167 |
| url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/2167 |
| identifier_str_mv |
10.21754/tecnia.v34i2.2167 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/2167/3129 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2024 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2024 TECNIA http://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol. 34 No. 2 (2024); 40-52 TECNIA; Vol. 34 Núm. 2 (2024); 40-52 2309-0413 0375-7765 10.21754/tecnia.v34i2 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| reponame_str |
Revistas - Universidad Nacional de Ingeniería |
| collection |
Revistas - Universidad Nacional de Ingeniería |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1838636208493690880 |
| score |
13.955691 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).