DISINFECTION OF WATER USING ELECTROINTENSIVE PROCESSES

Descripción del Articulo

The realization of the photo-electrochemical process consists in percolating the solution to be treated through an electrolytic reactor, in which the anodes coated with metal oxides remains under the effect of ultraviolet radiation (UV). The solution used in this study was contaminated artificially...

Descripción completa

Detalles Bibliográficos
Autores: Moura de Melo, Cláudia, Daniel Silva Siqueira, Santana dos Santos, Marluce, Calasans, Taíssa A. S., Nogueira Marques, Maria, Silva Lima, Álvaro, Bezerra Cavalcanti, Eliane
Formato: artículo
Fecha de Publicación:2013
Institución:Universidad Nacional Federico Villarreal
Repositorio:Revistas - Universidad Nacional Federico Villarreal
Lenguaje:español
OAI Identifier:oai:ojs2.revistas.unfv.edu.pe:article/946
Enlace del recurso:https://revistas.unfv.edu.pe/NH/article/view/946
Nivel de acceso:acceso abierto
Materia:Coliforms
disinfection
parasites
photolysis
Coliformes
Desinfección
Fotólisis
Parásitos
Desinfecção
Fotólise
Parasitas
Descripción
Sumario:The realization of the photo-electrochemical process consists in percolating the solution to be treated through an electrolytic reactor, in which the anodes coated with metal oxides remains under the effect of ultraviolet radiation (UV). The solution used in this study was contaminated artificially from fecal samples positive for bacteria and intestinal parasites. The evaluation of the process for the disinfection of water was held in photo-electrical-chemical reactor, with a total volume of 10.0 Lper batch system contaminated with human fecal material. It was used as the -1supporting electrolyte solution of sodium perchlorate at 0.1 mol. Land applying a current density -1of 14 mAwith the aid of a source and a flow rate of 250 L.h. The UVradiation was provided by a mercury vapor lamp of 55 Wwithout bulb shield. The center electrode is inserted through a quartz bulb. Samples were analyzed for pH, conductivity, chemical oxygen demand (COD), and turbidity. Aspects of microbiological and parasitological parameters were treated for 0, 5, 10, 20, and 30 min.. After 30 min., 98.9% reduction in parasitic forms (cysts and eggs) was observed and 99.8% of the colony of Escherichia coliwas present. There was a reduction in COD values (65.7%) and turbidity (92.3%) of samples after treatment exposure, as a result of electrochemical oxidation of organic compounds dissolved in the medium.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).