Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters

Descripción del Articulo

The efficiency of the 600 liters standard biodigester was evaluated, as well as the addition of 1 liter, 10 liters and 100 liters of microbial consortiums named probiotics on 13 samples of rural domestic wastewater treated in biodigesters in the Santeño Annex belonging to the El Carmen sector distri...

Descripción completa

Detalles Bibliográficos
Autores: Mejia Martinez, Elvis Yoel, Vasquez García, Ántero Celso, Gamarra Gonzáles, Julissa del Rocío, Cabrera Salazar, Tarcila Amelia, Morales Cabrera, Liz Amelia Juanitaflor
Formato: artículo
Fecha de Publicación:2021
Institución:Universidad César Vallejo
Repositorio:Revistas - Universidad César Vallejo
Lenguaje:español
OAI Identifier:oai:oai.revistas.ucv.edu.pe:article/1026
Enlace del recurso:http://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026
Nivel de acceso:acceso abierto
id REVUCV_de2b51c0652bc1333f9d523936402a4c
oai_identifier_str oai:oai.revistas.ucv.edu.pe:article/1026
network_acronym_str REVUCV
network_name_str Revistas - Universidad César Vallejo
repository_id_str
spelling Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigestersEficiencia de probióticos en la calidad del efluente de agua residual doméstica tratada en biodigestoresMejia Martinez, Elvis YoelVasquez García, Ántero CelsoGamarra Gonzáles, Julissa del RocíoCabrera Salazar, Tarcila AmeliaMorales Cabrera, Liz Amelia JuanitaflorThe efficiency of the 600 liters standard biodigester was evaluated, as well as the addition of 1 liter, 10 liters and 100 liters of microbial consortiums named probiotics on 13 samples of rural domestic wastewater treated in biodigesters in the Santeño Annex belonging to the El Carmen sector district of Tumán. After the activation of the probiotics, certain concentrations of the microorganisms were added. the microbiological was determined at the beginning of the experiment and after 24, 48 and 96 hours. In the Microbiological quality the concentrations of Thermotolerant Coliforms by the NMP / 100mL technique were determined. It was concluded that 1. The standard biodigester does not perform an efficient treatment in the microbiological quality of rural domestic wastewater, because the MPN value ≥ 2400 / 100mL of the thermotolerant coliforms are above the maximum permissible limits set by DS 004-2017-MINAM. 2. The most notable effect is the addition of 100 liters of microbial consortiums called probiotics, allowed to obtain domestic residual water of better microbiological quality, managed to reduce the thermotolerant coliforms until NMP = 150 / 100mL, value that is below the Maximum Limits permissible according to DS 004-2017-MINAM. 3. The infiltration time for the descent of 1 cm of water sheet is 5 minutes, classified according to theI.S.020 standard (septic tanks) in a middle class terrain.Keywords: Probiotics, residual water, biodigester. Se evaluó la eficiencia del biodigestor estándar de 600 litros, así como la adición de 1 litro, 10 litros y 100 litros de consorcios microbianos denominados probióticos sobre 13 muestras de agua residual domestica rural tratada en biodigestores en el Anexo Santeño perteneciente al Sector el Carmen del distrito de Tumán. Luego de la activación de los probióticos se adicionó determinadas concentraciones de los microorganismos. la microbiológica se determinó al inicio del experimento y transcurridas 24, 48 y 96 horas. En la calidad Microbiológica se determinaron las concentraciones de Coliformes Termotolerantes por la técnica del NMP/100mL, Se concluyó que 1. El biodigestor estándar no realiza un tratamiento eficiente en la calidad microbiológica del agua residual domestica rural, debido a que el valor del NMP ≥ 2400/100mL de las coliformes termotolerantes se encuentran por encima de los límites máximos permisibles fijados por el DS 004-2017-MINAM. 2. El efecto más notable es la adición de 100 litros de consorcios microbianos denominados probióticos, permitió obtener agua residual domestica de mejor calidad microbiológica, logró reducir las coliformes termotolerantes hasta NMP=150/100mL, valor que se encuentra por debajo de los Límites Máximos permisibles según el DS 004-2017-MINAM. 3. El tiempo de infiltración para eldescenso de 1 cm de lámina de agua es de 5 minutos, clasificándose según la norma I.S.020 (tanques sépticos) en un terreno de clase media.Palabras clave: Probióticos, agua residual, biodigestor. Universidad Cesar Vallejo2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttp://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026UCV Hacer; Vol. 10 No. 3 (2021): July - September; 11-16UCV Hacer; Vol. 10 Núm. 3 (2021): Julio - Septiembre; 11-162414-86952305-8552reponame:Revistas - Universidad César Vallejoinstname:Universidad César Vallejoinstacron:UCVspahttp://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026/1007Derechos de autor 2021 UCV Hacerhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:oai.revistas.ucv.edu.pe:article/10262023-03-27T16:41:40Z
dc.title.none.fl_str_mv Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
Eficiencia de probióticos en la calidad del efluente de agua residual doméstica tratada en biodigestores
title Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
spellingShingle Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
Mejia Martinez, Elvis Yoel
title_short Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
title_full Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
title_fullStr Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
title_full_unstemmed Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
title_sort Efficiency of probiotics in the quality of the effluent of domestic wastewater treated in biodigesters
dc.creator.none.fl_str_mv Mejia Martinez, Elvis Yoel
Vasquez García, Ántero Celso
Gamarra Gonzáles, Julissa del Rocío
Cabrera Salazar, Tarcila Amelia
Morales Cabrera, Liz Amelia Juanitaflor
author Mejia Martinez, Elvis Yoel
author_facet Mejia Martinez, Elvis Yoel
Vasquez García, Ántero Celso
Gamarra Gonzáles, Julissa del Rocío
Cabrera Salazar, Tarcila Amelia
Morales Cabrera, Liz Amelia Juanitaflor
author_role author
author2 Vasquez García, Ántero Celso
Gamarra Gonzáles, Julissa del Rocío
Cabrera Salazar, Tarcila Amelia
Morales Cabrera, Liz Amelia Juanitaflor
author2_role author
author
author
author
description The efficiency of the 600 liters standard biodigester was evaluated, as well as the addition of 1 liter, 10 liters and 100 liters of microbial consortiums named probiotics on 13 samples of rural domestic wastewater treated in biodigesters in the Santeño Annex belonging to the El Carmen sector district of Tumán. After the activation of the probiotics, certain concentrations of the microorganisms were added. the microbiological was determined at the beginning of the experiment and after 24, 48 and 96 hours. In the Microbiological quality the concentrations of Thermotolerant Coliforms by the NMP / 100mL technique were determined. It was concluded that 1. The standard biodigester does not perform an efficient treatment in the microbiological quality of rural domestic wastewater, because the MPN value ≥ 2400 / 100mL of the thermotolerant coliforms are above the maximum permissible limits set by DS 004-2017-MINAM. 2. The most notable effect is the addition of 100 liters of microbial consortiums called probiotics, allowed to obtain domestic residual water of better microbiological quality, managed to reduce the thermotolerant coliforms until NMP = 150 / 100mL, value that is below the Maximum Limits permissible according to DS 004-2017-MINAM. 3. The infiltration time for the descent of 1 cm of water sheet is 5 minutes, classified according to theI.S.020 standard (septic tanks) in a middle class terrain.Keywords: Probiotics, residual water, biodigester.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artículo evaluado por pares
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026
url http://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://revistas.ucv.edu.pe/index.php/ucv-hacer/article/view/1026/1007
dc.rights.none.fl_str_mv Derechos de autor 2021 UCV Hacer
https://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2021 UCV Hacer
https://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Cesar Vallejo
publisher.none.fl_str_mv Universidad Cesar Vallejo
dc.source.none.fl_str_mv UCV Hacer; Vol. 10 No. 3 (2021): July - September; 11-16
UCV Hacer; Vol. 10 Núm. 3 (2021): Julio - Septiembre; 11-16
2414-8695
2305-8552
reponame:Revistas - Universidad César Vallejo
instname:Universidad César Vallejo
instacron:UCV
instname_str Universidad César Vallejo
instacron_str UCV
institution UCV
reponame_str Revistas - Universidad César Vallejo
collection Revistas - Universidad César Vallejo
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1846245725429563392
score 12.789436
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).