Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study.
Descripción del Articulo
Objective: To evaluate and compare the flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resins. Materials and methods: Thirty 2mm x 2mm x 25mm specimens of Tetric N-Flow (TNF), Filtek Bulk Fill Flowable Restorative (FBF) and Beautifil Flow Plus F00 (BFP) flow...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2023 |
| Institución: | Universidad Científica del Sur |
| Repositorio: | Revistas - Universidad Científica del Sur |
| Lenguaje: | español |
| OAI Identifier: | oai:revistas.cientifica.edu.pe:article/1642 |
| Enlace del recurso: | https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/1642 |
| Nivel de acceso: | acceso abierto |
| Materia: | resinas compuestas resistencia flexural propiedades mecanicas composite resins flexural resistance mechanic properties |
| id |
REVUCS_0fb613154b6b9708c27e09babff984f9 |
|---|---|
| oai_identifier_str |
oai:revistas.cientifica.edu.pe:article/1642 |
| network_acronym_str |
REVUCS |
| network_name_str |
Revistas - Universidad Científica del Sur |
| repository_id_str |
. |
| spelling |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study.Resistencia flexural de las resinas fluida convencional, fluida bulk fill y fluida de alta carga: estudio in vitroSulca Gonzales, Edith Liliana López-Flores, Ana Isabel resinas compuestasresistencia flexuralpropiedades mecanicascomposite resinsflexural resistancemechanic propertiesObjective: To evaluate and compare the flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resins. Materials and methods: Thirty 2mm x 2mm x 25mm specimens of Tetric N-Flow (TNF), Filtek Bulk Fill Flowable Restorative (FBF) and Beautifil Flow Plus F00 (BFP) flowable resins were made up; they were distributed into three groups according to brand (n=10) and stored in distilled water for 24 hours at 37ºC. The 3-point bending test according to ISO 4049 was performed on a universal testing machine at a speed of 0.5 mm/min until fracture. The results were evaluated with Anova and Tukey tests. P<0.05. Results: Statistically significant differences were found between the groups with a value of p=0.011. According to the statistical analysis, the groups that showed statistically significant differences were the BFP and TNF groups (p=0.015) and the BFP and FBF groups (p=0.035), while no statistically significant difference was found in the TNF and FBF groups. Conclusion: The high-filled flowable resin presents better flexural strength compared to the conventional flowable and bulk fill flowable resins, while the conventional and bulk fill flowable resins have no statistically significant difference.Objetivo: Evaluar y comparar la resistencia flexural de las resinas fluida convencional, fluida bulk fill y fluida de alta carga. Materiales y métodos: Se confeccionaron treinta especímenes de 2 mm x 2 mm x 25 mm de las resinas fluidas Tetric N-Flow (TNF), Filtek Bulk Fill Flowable Restorative (FBF) y Beautifil Flow Plus F00 (BFP), las cuales se distribuyeron en tres grupos, de acuerdo con la marca (n = 10), y se almacenaron en agua destilada durante 24 horas a 37 °C. Se realizó la prueba de flexión de 3 puntos, de acuerdo con la norma ISO 4049, en una máquina de ensayo universal a una velocidad de 0,5 mm/min hasta la fractura. Los resultados se evaluaron con las pruebas de Anova y Tukey. P < 0,05. Resultados: Se encontró diferencias estadísticamente significativas entre los grupos con un valor de p = 0,011. Los grupos que mostraron diferencias estadísticamente significativas fueron los grupos BFP y TNF (p = 0,015) y los grupos BFP y FBF (p = 0,035), mientras que entre los grupos TNF y FBF no se encontró diferencia estadísticamente significativa. Conclusión: La resina fluida de alta carga presenta mejor resistencia flexural comparada con las resinas fluida convencional y fluida bulk fill, mientas que las resinas fluidas convencional y bulk fill no muestran diferencia estadísticamente significativa.Carrera de Estomatología de la Universidad Científica del Sur2023-09-26info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.cientifica.edu.pe/index.php/odontologica/article/view/164210.21142/2523-2754-1103-2023-161Revista Científica Odontológica; Vol. 11 Núm. 3 (2023); e161Revista Científica Odontológica; Vol. 11 No. 3 (2023); e1612523-27542310-2594reponame:Revistas - Universidad Científica del Surinstname:Universidad Científica del Surinstacron:CIENTÍFICAspahttps://revistas.cientifica.edu.pe/index.php/odontologica/article/view/1642/1181info:eu-repo/semantics/openAccessoai:revistas.cientifica.edu.pe:article/16422023-09-27T21:02:59Z |
| dc.title.none.fl_str_mv |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. Resistencia flexural de las resinas fluida convencional, fluida bulk fill y fluida de alta carga: estudio in vitro |
| title |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| spellingShingle |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. Sulca Gonzales, Edith Liliana resinas compuestas resistencia flexural propiedades mecanicas composite resins flexural resistance mechanic properties |
| title_short |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| title_full |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| title_fullStr |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| title_full_unstemmed |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| title_sort |
Flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resin composites: in vitro study. |
| dc.creator.none.fl_str_mv |
Sulca Gonzales, Edith Liliana López-Flores, Ana Isabel |
| author |
Sulca Gonzales, Edith Liliana |
| author_facet |
Sulca Gonzales, Edith Liliana López-Flores, Ana Isabel |
| author_role |
author |
| author2 |
López-Flores, Ana Isabel |
| author2_role |
author |
| dc.subject.none.fl_str_mv |
resinas compuestas resistencia flexural propiedades mecanicas composite resins flexural resistance mechanic properties |
| topic |
resinas compuestas resistencia flexural propiedades mecanicas composite resins flexural resistance mechanic properties |
| description |
Objective: To evaluate and compare the flexural strength of conventional flowable, bulk fill flowable and highly filled flowable resins. Materials and methods: Thirty 2mm x 2mm x 25mm specimens of Tetric N-Flow (TNF), Filtek Bulk Fill Flowable Restorative (FBF) and Beautifil Flow Plus F00 (BFP) flowable resins were made up; they were distributed into three groups according to brand (n=10) and stored in distilled water for 24 hours at 37ºC. The 3-point bending test according to ISO 4049 was performed on a universal testing machine at a speed of 0.5 mm/min until fracture. The results were evaluated with Anova and Tukey tests. P<0.05. Results: Statistically significant differences were found between the groups with a value of p=0.011. According to the statistical analysis, the groups that showed statistically significant differences were the BFP and TNF groups (p=0.015) and the BFP and FBF groups (p=0.035), while no statistically significant difference was found in the TNF and FBF groups. Conclusion: The high-filled flowable resin presents better flexural strength compared to the conventional flowable and bulk fill flowable resins, while the conventional and bulk fill flowable resins have no statistically significant difference. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023-09-26 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/1642 10.21142/2523-2754-1103-2023-161 |
| url |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/1642 |
| identifier_str_mv |
10.21142/2523-2754-1103-2023-161 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/1642/1181 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Carrera de Estomatología de la Universidad Científica del Sur |
| publisher.none.fl_str_mv |
Carrera de Estomatología de la Universidad Científica del Sur |
| dc.source.none.fl_str_mv |
Revista Científica Odontológica; Vol. 11 Núm. 3 (2023); e161 Revista Científica Odontológica; Vol. 11 No. 3 (2023); e161 2523-2754 2310-2594 reponame:Revistas - Universidad Científica del Sur instname:Universidad Científica del Sur instacron:CIENTÍFICA |
| instname_str |
Universidad Científica del Sur |
| instacron_str |
CIENTÍFICA |
| institution |
CIENTÍFICA |
| reponame_str |
Revistas - Universidad Científica del Sur |
| collection |
Revistas - Universidad Científica del Sur |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846879642808483840 |
| score |
12.688246 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).