Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019.
Descripción del Articulo
The success of a rehabilitation on implants lies in the correct three-dimensional positioning of the implant and a surgical guide that has been previously planned with a resale protocol brings us closer to that objective; the ROGA surgical guide is created that aims to be more effective than the fre...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad Católica de Santa María |
Repositorio: | Revistas - Universidad Católica de Santa María |
Lenguaje: | español |
OAI Identifier: | oai:ojs.revistas.ucsm.edu.pe:article/278 |
Enlace del recurso: | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/278 |
Nivel de acceso: | acceso abierto |
Materia: | guía quirúrgica implantes posicionamiento tridimensional |
id |
REVUCSM_68331aabc4105034ce7cd0156c22de71 |
---|---|
oai_identifier_str |
oai:ojs.revistas.ucsm.edu.pe:article/278 |
network_acronym_str |
REVUCSM |
network_name_str |
Revistas - Universidad Católica de Santa María |
repository_id_str |
|
spelling |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. Evaluación de la eficacia de la guía quirúrgica ROGA y la técnica a mano alzada en el posicionamiento tridimensional del implante en pacientes del Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019.Roxana Gamarra OjedaAlberto Cáceres Huamboguía quirúrgicaimplantesposicionamiento tridimensionalThe success of a rehabilitation on implants lies in the correct three-dimensional positioning of the implant and a surgical guide that has been previously planned with a resale protocol brings us closer to that objective; the ROGA surgical guide is created that aims to be more effective than the freehand technique in such positioning; To evaluate it, 8 implants were placed with ROGA Guide and 8 implants freehand, and then the three-dimensional positioning was evaluated using the before and after tomographs, 5 measurements, mesiodistal and palatal vestibule both at coronal level and at apical and apicocoronal level were evaluated ; the implants placed with the ROGA guide did not have any deviation at the coronal mesiodistal level and in the other measures they had less deviations in relation to the reverse planning with an average of 0.457mm unlike the raised hand that had an average deviation of up to 1 , 91 mm ;; statistically significant difference was found in the other measures there was no statistically significant difference. However, in implants a small millimeter deviation can affect the rehabilitative treatment. It was concluded that the ROGA guide is more effective in the three-dimensional positioning of the dental implant.El éxito de una rehabilitación sobre implantes radica en el correcto posicionamiento tridimensional del implante y una guía quirúrgica que ha sido previamente planeada con un protocolo reveso nos acerca a ese objetivo; se crea la guía quirúrgica ROGA que pretende ser más eficaz que la técnica a mano alzada en dicho posicionamiento; para evaluarla se colocó 8 implantes con Guía ROGA y 8 implantes a mano alzada, y luego se evaluó el posicionamiento tridimensional utilizando las tomografías del antes y después, se evaluaron 5 medidas, mesiodistal y vestíbulo palatina ambas a nivel coronal y a nivel apical y la ápicocoronal; los implantes colocados con la guía ROGA no tuvieron ninguna desviación a nivel mesiodistal coronal y en las demás medidas tuvieron menos desviaciones con relación a la planificación reversa con una media de 0,457mm a diferencia de la de mano alzada que tuvo una desviación media de hasta 1,91 mm; se encontró diferencia estadísticamente significativo en las demás medidas no hubo diferencia estadísticamente significativo. Sin embargo, en implantes una pequeña desviación milimétrica puede afectar el tratamiento rehabilitador. Se concluyó que la guía ROGA es más eficaz en el posicionamiento tridimensional del implante dental.Universidad Católica de Santa María2020-10-30info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/27810.35286/veritas.v21i2.278Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-54Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-54Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-541684-78221684-782210.35286/veritas.v21i2reponame:Revistas - Universidad Católica de Santa Maríainstname:Universidad Católica de Santa Maríainstacron:UCSMspahttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/278/198Derechos de autor 2020 Veritasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.ucsm.edu.pe:article/2782021-11-19T17:27:02Z |
dc.title.none.fl_str_mv |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. Evaluación de la eficacia de la guía quirúrgica ROGA y la técnica a mano alzada en el posicionamiento tridimensional del implante en pacientes del Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
title |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
spellingShingle |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. Roxana Gamarra Ojeda guía quirúrgica implantes posicionamiento tridimensional |
title_short |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
title_full |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
title_fullStr |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
title_full_unstemmed |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
title_sort |
Evaluation of the efficacy of the ROGA surgical guide and the freehand technique in the three-dimensional positioning of the implant in patients of the Centro Odontológico de la Universidad Católica de Santa María de Arequipa 2019. |
dc.creator.none.fl_str_mv |
Roxana Gamarra Ojeda Alberto Cáceres Huambo |
author |
Roxana Gamarra Ojeda |
author_facet |
Roxana Gamarra Ojeda Alberto Cáceres Huambo |
author_role |
author |
author2 |
Alberto Cáceres Huambo |
author2_role |
author |
dc.subject.none.fl_str_mv |
guía quirúrgica implantes posicionamiento tridimensional |
topic |
guía quirúrgica implantes posicionamiento tridimensional |
description |
The success of a rehabilitation on implants lies in the correct three-dimensional positioning of the implant and a surgical guide that has been previously planned with a resale protocol brings us closer to that objective; the ROGA surgical guide is created that aims to be more effective than the freehand technique in such positioning; To evaluate it, 8 implants were placed with ROGA Guide and 8 implants freehand, and then the three-dimensional positioning was evaluated using the before and after tomographs, 5 measurements, mesiodistal and palatal vestibule both at coronal level and at apical and apicocoronal level were evaluated ; the implants placed with the ROGA guide did not have any deviation at the coronal mesiodistal level and in the other measures they had less deviations in relation to the reverse planning with an average of 0.457mm unlike the raised hand that had an average deviation of up to 1 , 91 mm ;; statistically significant difference was found in the other measures there was no statistically significant difference. However, in implants a small millimeter deviation can affect the rehabilitative treatment. It was concluded that the ROGA guide is more effective in the three-dimensional positioning of the dental implant. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-10-30 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/278 10.35286/veritas.v21i2.278 |
url |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/278 |
identifier_str_mv |
10.35286/veritas.v21i2.278 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/278/198 |
dc.rights.none.fl_str_mv |
Derechos de autor 2020 Veritas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2020 Veritas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Católica de Santa María |
publisher.none.fl_str_mv |
Universidad Católica de Santa María |
dc.source.none.fl_str_mv |
Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-54 Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-54 Veritas; Vol. 21 Núm. 2 (2020): VÉRITAS: Investigación, Innovación y Desarrollo; 51-54 1684-7822 1684-7822 10.35286/veritas.v21i2 reponame:Revistas - Universidad Católica de Santa María instname:Universidad Católica de Santa María instacron:UCSM |
instname_str |
Universidad Católica de Santa María |
instacron_str |
UCSM |
institution |
UCSM |
reponame_str |
Revistas - Universidad Católica de Santa María |
collection |
Revistas - Universidad Católica de Santa María |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1846064239663382528 |
score |
13.02468 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).