Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?

Descripción del Articulo

Severe fetal anemia can be detected in utero through the measurement of the maximum systolic velocity of the Middle Cerebral Artery (VSmax-MCA). The false positive rate of this measurement technique is unfortunately high (34%), which is why the maternal-fetal clinical correlate is suggested and cond...

Descripción completa

Detalles Bibliográficos
Autores: Huertas, Erasmo, Sugajara, Ricardo, Ventura, Walter, Castillo, Walter
Formato: artículo
Fecha de Publicación:2020
Institución:Instituto Nacional Materno Perinatal
Repositorio:Revista Peruana de Investigación Materno Perinatal
Lenguaje:español
OAI Identifier:oai:investigacionmaternoperinatal.inmp.gob.pe:article/205
Enlace del recurso:https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205
Nivel de acceso:acceso abierto
Materia:Arteria cerebral media
Velocidad sistólica máxima
Anemia fetal
Middle cerebral artery
Maximum systolic velocity
Fetal anemia
id REVINMP_5ecac8c5d7e0ffd1e120b0ff3e0f76ee
oai_identifier_str oai:investigacionmaternoperinatal.inmp.gob.pe:article/205
network_acronym_str REVINMP
network_name_str Revista Peruana de Investigación Materno Perinatal
repository_id_str
spelling Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?Velocidad sistólica máxima de la arteria cerebral media elevada en fetos sin anemia: ¿Falsos postivos?Huertas, ErasmoSugajara, RicardoVentura, WalterCastillo, WalterArteria cerebral mediaVelocidad sistólica máximaAnemia fetalMiddle cerebral arteryMaximum systolic velocityFetal anemiaSevere fetal anemia can be detected in utero through the measurement of the maximum systolic velocity of the Middle Cerebral Artery (VSmax-MCA). The false positive rate of this measurement technique is unfortunately high (34%), which is why the maternal-fetal clinical correlate is suggested and conditions that falsely elevate the SPV are ruled out before making any decision regarding the diagnosis of fetal anemia. We present a case of a fetus with altered VSmax-ACM above 1.5 MoM who was born with normal hemoglobin values.La anemia fetal severa pude ser detectada intrautero a través de la medición de velocidad sistólica máxima de la Arteria Cerebral Media (VSmax-ACM). La tasa de falsos positivos de esta técnica de medición desafortunadamente es alta (34%) por lo que se sugiere el correlato clínico materno fetal  y descartar condiciones que eleven falsamente la VPS antes de tomar alguna decisión respecto del diagnóstico de ser de anemia fetal. Presentamos un caso de un feto con VSmax-ACM alterado por encima de 1.5 MoM que nació con valores de hemoglobina normales.Instituto Nacional Materno Perinatal (INMP), Lima - Perú.2020-09-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/20510.33421/inmp.2020205Revista Peruana de Investigación Materno Perinatal; Vol. 9 No. 2 (2020): Peruvian Journal of Maternal Perinatal Research; 42-46Revista Peruana de Investigación Materno Perinatal; Vol. 9 Núm. 2 (2020): Revista Peruana de Investigación Materno Perinatal; 42-462663-113X2305-388710.33421/92reponame:Revista Peruana de Investigación Materno Perinatalinstname:Instituto Nacional Materno Perinatalinstacron:INMPspahttps://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205/201https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205/220Derechos de autor 2022 Revista Peruana de Investigación Materno Perinatalinfo:eu-repo/semantics/openAccessoai:investigacionmaternoperinatal.inmp.gob.pe:article/2052024-10-31T05:55:02Z
dc.title.none.fl_str_mv Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
Velocidad sistólica máxima de la arteria cerebral media elevada en fetos sin anemia: ¿Falsos postivos?
title Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
spellingShingle Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
Huertas, Erasmo
Arteria cerebral media
Velocidad sistólica máxima
Anemia fetal
Middle cerebral artery
Maximum systolic velocity
Fetal anemia
title_short Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
title_full Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
title_fullStr Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
title_full_unstemmed Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
title_sort Maximum systolic speed of high average cerebral artery in fetus without anemia: positive false?
dc.creator.none.fl_str_mv Huertas, Erasmo
Sugajara, Ricardo
Ventura, Walter
Castillo, Walter
author Huertas, Erasmo
author_facet Huertas, Erasmo
Sugajara, Ricardo
Ventura, Walter
Castillo, Walter
author_role author
author2 Sugajara, Ricardo
Ventura, Walter
Castillo, Walter
author2_role author
author
author
dc.subject.none.fl_str_mv Arteria cerebral media
Velocidad sistólica máxima
Anemia fetal
Middle cerebral artery
Maximum systolic velocity
Fetal anemia
topic Arteria cerebral media
Velocidad sistólica máxima
Anemia fetal
Middle cerebral artery
Maximum systolic velocity
Fetal anemia
description Severe fetal anemia can be detected in utero through the measurement of the maximum systolic velocity of the Middle Cerebral Artery (VSmax-MCA). The false positive rate of this measurement technique is unfortunately high (34%), which is why the maternal-fetal clinical correlate is suggested and conditions that falsely elevate the SPV are ruled out before making any decision regarding the diagnosis of fetal anemia. We present a case of a fetus with altered VSmax-ACM above 1.5 MoM who was born with normal hemoglobin values.
publishDate 2020
dc.date.none.fl_str_mv 2020-09-07
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205
10.33421/inmp.2020205
url https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205
identifier_str_mv 10.33421/inmp.2020205
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205/201
https://investigacionmaternoperinatal.inmp.gob.pe/index.php/rpinmp/article/view/205/220
dc.rights.none.fl_str_mv Derechos de autor 2022 Revista Peruana de Investigación Materno Perinatal
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2022 Revista Peruana de Investigación Materno Perinatal
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Instituto Nacional Materno Perinatal (INMP), Lima - Perú.
publisher.none.fl_str_mv Instituto Nacional Materno Perinatal (INMP), Lima - Perú.
dc.source.none.fl_str_mv Revista Peruana de Investigación Materno Perinatal; Vol. 9 No. 2 (2020): Peruvian Journal of Maternal Perinatal Research; 42-46
Revista Peruana de Investigación Materno Perinatal; Vol. 9 Núm. 2 (2020): Revista Peruana de Investigación Materno Perinatal; 42-46
2663-113X
2305-3887
10.33421/92
reponame:Revista Peruana de Investigación Materno Perinatal
instname:Instituto Nacional Materno Perinatal
instacron:INMP
instname_str Instituto Nacional Materno Perinatal
instacron_str INMP
institution INMP
reponame_str Revista Peruana de Investigación Materno Perinatal
collection Revista Peruana de Investigación Materno Perinatal
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1843618117332238336
score 13.754616
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).