Cranial reconstruction using computer designed polieteretercetone implant
Descripción del Articulo
Background: Craneoplasty has 2 purposes; protection of the brain and a satisfying cosmetic result. There are different alloplast grafts to cranial reconstruction. Clinical case: A decompressive craniectomy was performed in a 29 years old man who had a severe brain trauma one month...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2010 |
| Institución: | Colegio Médico del Perú |
| Repositorio: | Acta Médica Peruana |
| Lenguaje: | español |
| OAI Identifier: | oai:amp.cmp.org.pe:article/1384 |
| Enlace del recurso: | https://amp.cmp.org.pe/index.php/AMP/article/view/1384 |
| Nivel de acceso: | acceso abierto |
| Materia: | Cráneo traumatismos craneocerebrales craniectomia descompresiva Skull craniocerebral injuries descompresive craniectomy |
| id |
REVCMP_07c75dcc7edb59e138504ed397276ff7 |
|---|---|
| oai_identifier_str |
oai:amp.cmp.org.pe:article/1384 |
| network_acronym_str |
REVCMP |
| network_name_str |
Acta Médica Peruana |
| repository_id_str |
. |
| spelling |
Cranial reconstruction using computer designed polieteretercetone implantCraneoplastía con implante de polieteretercetona diseñado por computadoraCasallo Quiliano, Carlos Arturo Zenón Tantas Oblitas, Gustavo Pineda García, Ronald Augusto Cráneotraumatismos craneocerebralescraniectomia descompresivaSkullcraniocerebral injuriesdescompresive craniectomyBackground: Craneoplasty has 2 purposes; protection of the brain and a satisfying cosmetic result. There are different alloplast grafts to cranial reconstruction. Clinical case: A decompressive craniectomy was performed in a 29 years old man who had a severe brain trauma one month before admission. Clinically he is in coma, with a left large skull defect. After two months the patient is underwent to cranial reconstruction using computer designed polyetheretherketone implant, without complications related to surgery until now. Conclusion: Craneoplasty using computer designed PEEK implant is safe, offers great adaptability and biocompatibility, and minor surgical time.Introducción: Existen diferentes materiales para realizar una craneoplastía, siendo el objetivo principal la protección cerebral y el resultado cosmético. Caso clínico: Varón de 29 años que 1 mes antes de ingreso tuvo un trauma encéfalo craneano grave, siendo sometido a hemicraniectomía descompresiva de urgencia. Neurológicamente el paciente se encuentra en coma vigil, traqueostomía, y con un gran defecto óseo de hemicráneo izquierdo. Dos meses después es sometido a una craneoplastía con implante de polieteretercetona diseñado por computadora, fijado con miniplacas, con evolución postoperatoria sin complicaciones. Conclusión: La craneoplastía con implante PEEK diseñado por computadora, es segura, brinda gran adaptabilidad, biocompatibilidad y menor tiempo quirúrgico.Colegio Médico del Perú2010-09-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://amp.cmp.org.pe/index.php/AMP/article/view/1384ACTA MEDICA PERUANA; Vol. 27 No. 3 (2010); 193-195ACTA MEDICA PERUANA; Vol. 27 Núm. 3 (2010); 193-1951728-59171018-8800reponame:Acta Médica Peruanainstname:Colegio Médico del Perúinstacron:CMPspahttps://amp.cmp.org.pe/index.php/AMP/article/view/1384/837Copyright (c) 2020 ACTA MEDICA PERUANAinfo:eu-repo/semantics/openAccessoai:amp.cmp.org.pe:article/13842023-07-06T06:00:20Z |
| dc.title.none.fl_str_mv |
Cranial reconstruction using computer designed polieteretercetone implant Craneoplastía con implante de polieteretercetona diseñado por computadora |
| title |
Cranial reconstruction using computer designed polieteretercetone implant |
| spellingShingle |
Cranial reconstruction using computer designed polieteretercetone implant Casallo Quiliano, Carlos Arturo Cráneo traumatismos craneocerebrales craniectomia descompresiva Skull craniocerebral injuries descompresive craniectomy |
| title_short |
Cranial reconstruction using computer designed polieteretercetone implant |
| title_full |
Cranial reconstruction using computer designed polieteretercetone implant |
| title_fullStr |
Cranial reconstruction using computer designed polieteretercetone implant |
| title_full_unstemmed |
Cranial reconstruction using computer designed polieteretercetone implant |
| title_sort |
Cranial reconstruction using computer designed polieteretercetone implant |
| dc.creator.none.fl_str_mv |
Casallo Quiliano, Carlos Arturo Zenón Tantas Oblitas, Gustavo Pineda García, Ronald Augusto |
| author |
Casallo Quiliano, Carlos Arturo |
| author_facet |
Casallo Quiliano, Carlos Arturo Zenón Tantas Oblitas, Gustavo Pineda García, Ronald Augusto |
| author_role |
author |
| author2 |
Zenón Tantas Oblitas, Gustavo Pineda García, Ronald Augusto |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Cráneo traumatismos craneocerebrales craniectomia descompresiva Skull craniocerebral injuries descompresive craniectomy |
| topic |
Cráneo traumatismos craneocerebrales craniectomia descompresiva Skull craniocerebral injuries descompresive craniectomy |
| description |
Background: Craneoplasty has 2 purposes; protection of the brain and a satisfying cosmetic result. There are different alloplast grafts to cranial reconstruction. Clinical case: A decompressive craniectomy was performed in a 29 years old man who had a severe brain trauma one month before admission. Clinically he is in coma, with a left large skull defect. After two months the patient is underwent to cranial reconstruction using computer designed polyetheretherketone implant, without complications related to surgery until now. Conclusion: Craneoplasty using computer designed PEEK implant is safe, offers great adaptability and biocompatibility, and minor surgical time. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010-09-29 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://amp.cmp.org.pe/index.php/AMP/article/view/1384 |
| url |
https://amp.cmp.org.pe/index.php/AMP/article/view/1384 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://amp.cmp.org.pe/index.php/AMP/article/view/1384/837 |
| dc.rights.none.fl_str_mv |
Copyright (c) 2020 ACTA MEDICA PERUANA info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Copyright (c) 2020 ACTA MEDICA PERUANA |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Colegio Médico del Perú |
| publisher.none.fl_str_mv |
Colegio Médico del Perú |
| dc.source.none.fl_str_mv |
ACTA MEDICA PERUANA; Vol. 27 No. 3 (2010); 193-195 ACTA MEDICA PERUANA; Vol. 27 Núm. 3 (2010); 193-195 1728-5917 1018-8800 reponame:Acta Médica Peruana instname:Colegio Médico del Perú instacron:CMP |
| instname_str |
Colegio Médico del Perú |
| instacron_str |
CMP |
| institution |
CMP |
| reponame_str |
Acta Médica Peruana |
| collection |
Acta Médica Peruana |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1849052452259627008 |
| score |
13.067735 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).